Rasmussen Chillbuster CL-11-C9A-ME Owner's Manual

Manual is about: Decorative Vented/Unvented Gas Log Set

Summary of Chillbuster CL-11-C9A-ME

  • Page 1

    1 in the commonwealth of massachusetts: • installation must be performed by a licensed plumber or gas fitter. • the chimney flue damper, when used with gas logs, will be welded open or completely removed. • a co detector shall be installed in the room where the appliance is installed. Set size model...

  • Page 2

    2 this is an unvented gas-fired heater. It uses air (oxygen) from the room in which it is installed. Provisions for adequate combustion and ventilation air must be provided. Refer to section "provisions for adequate combustion and ventilation air" (pages 4 and 5.) . All applications (installation) a...

  • Page 3

    3 2. This appliance is for use with the type of gas indicated on the rating plate. This appliance is not field convertible for use with other gases. Gas type conversion may only be accomplished at the factory. 3. Do not use this appliance if any part has been under water. Immediately call a qualifie...

  • Page 4

    4 vented applications (additional requirements) damper stop clamp damper chimney flue general information: 1. The minimum permanent free opening of the fireplace chimney or chimney damper must be at least 29 sq. Inches based upon a minimum chimney height of at least 10 feet. 2. Solid fuels shall not...

  • Page 5: Vent Free Operation

    5 adequate combustion and ventilation air options: • increase the maximum supportable btu/hr by adding to the number of rooms which comprise the "space". To do this you must ether completely remove the door to an adjoining room or provide two permanent ventilation grills; one within 12" of the ceili...

  • Page 6: Vent Free Operation

    6 warning: carbon monoxide poisoning may lead to death when used without fresh air, gas log sets may give off carbon monoxide, an odorless, colorless, poisonous gas. Some people, pregnant women, persons with heart or lung disease, anemia, or under the influence of alcohol and persons at high altitud...

  • Page 7

    7 mantel clearance without hood: non-combustible or heat resistant material horizontal projection from face of fireplace top of firebox opening 30"+ 28" 25" 20" 12" vertical distances to underside of mantel .75" 2.5" 6" 8" 10" height above projection out opening from face 0 -12" 0" 12" - 20" 3/4" 20...

  • Page 8

    8 all applications (vented and vent free operation) coal placement: note: to ensure optimum performance, coals must be placed on burner as depicted. . 1. Front and rear bottom coals: place bottom coals (c9a - 4 coal array; c9b -5 coal array) into stainless steel lifters and center. 2. Top coals: pla...

  • Page 9

    9 all applications (vented and vent free operation) lighting and operation control locations and description all models (c9-s-r) • primary gas valve control knob (switch models): pilot lighting and valve gas output adjustment from off to full. See figure 7 • switch models (c9-s) 3 way selector switc...

  • Page 10

    10 switch control accessory options: ultra-sonic wireless remote (f10-ab) wall switch (ws-1) wall timer (60 minute timer) (wt-1) ir wireless remote with thermostat (irrc) wall thermostat (ts-1) crackler sound module for f10ab or irrc (cf5) remote log house (rh) heat resistant "log" for f10-ab or irr...

  • Page 11

    11 pilot location: pilot is located on left side behind front burner. Op america (remote models) the pilot flame should be steady and soft blue surrounding 1/8 inch of the thermocouple tip as shown in figure 9. Op america millivolt (switch model) note: the op america millivolt pilot/ods is equipped ...

  • Page 12

    12 • will produce water vapor (increase indoor humidity) which may be beneficial during the dry heating season. Customer responsibilities and annual maintenance: • keep the area around the chillbuster free and clear from debris. From time to time, visually check pilot and burner flames for proper ap...

  • Page 13

    13 3 2 parts list c9-s/r (switch/remote)-n/p 1 4 5 6 7 8 10 30 31 12 9 13 20 11 21 22 32 1. Top center coal array 5. 1/4" pilot supply tubing 11. Front burner orifice holder c9-r (remote) (3 coal-c9a; 4 coal-c9b 6. 1/4" front burner gas 12. Heat shield 30. Remote valve 2. Bottom coal array (2) suppl...

  • Page 14

    14 two year consumer product warranty the following warranty has been drafted to comply with the magnuson-moss warranty act applicable to products manufactured after july 4, 1975. It replaces and supersedes any warranty in this package or in any printed literature..

  • Page 15

    15 limited warranty: rasmussen iron works inc, 12028 e. Philadelphia street, whittier california, u.S.A.., warrants this gas log set and accessories against defects in materials and workmanship, and suitable for a particular purpose, for a period of: (1) log casting - all logs are guaranteed against...