ALL APPLICATIONS (VENTED and VENT FREE OPERATION)
C2A-M and C2B-M (MANUAL CONTROL) OPERATION
Rasmussen
Manufactured by:
Whittier, CA USA
Ignitor Button
Figure 9
Pilot Lighting, Operation, and Shutting Down:
1. Slightly push knob and turn to “S E A S O N O F F ”. Figure 10
2. Before lighting, wait at least five minutes (10 minutes for LP gas) to
allow gas which may have accumulated around burner to escape.
3. Slightly push knob and turn to “P I L O T / O F F ”. Figure 10
4. Depress valve knob until air is bled and gas flows to pilot. Press Piezo
IGNITOR Button (Figure 9) to light pilot. Continue to hold valve knob in
until Pilot remains lit when knob is released.
5. Slowly turn knob to “O N ”. The rear burner will light from the pilot. The
front burner will light from the carry-over tube.
6. If appliance fails to light or if pilot goes out, repeat steps 1 through 5 .
7. For complete shutdown, push knob in and turn to “SEASON/OFF”.
Pilot
Access
Port
AT PILOT POSITION
SLIGHT PUSH TO
TURN OFF
FULL PUSH TO
LIGHT
OFF ON
. . .
Valve Knob
Figure 10
C2A/B-S or C2A/B-R (Switch or Remote Millivolt) LIGHTING
Control Pilot Lighting:
N O T E : The Gas Cock Dial has complete control of gas to pilot and burner. The Gas
Cock Dial cannot be turned to "OFF" without first depressing dial in "PILOT" position and
then rotating clockwise to "OFF".
1.
Depress and turn Gas Cock Dial to "OFF" position.
2.
Put the Control Selector Switch into the O F F position. Any Accessory Controls
must also be turned "OFF" (Remote Control) or to lowest temperature setting (Thermostat)
3.
Wait at least 5 minutes to allow gas which may have accumulated around burner to escape.
4.
Turn Gas Cock Dial to "PILOT" position.
5.
Depress and hold Gas Cock Dial until air is bled and gas flows to pilot.
SELECTOR SWITCH
Figure 11
SWITCH OFF REMOTE
ON ACCESS
ON
6.
Press Piezo Ignitor Button to
light pilot. Continue to holding in the
Gas Cock Dial until the Pilot flame
remains lit when knob is released
(approximately 60 to 90 seconds). If
Pilot does not remain lit, repeat steps
1 through 5 and allow more time after
Pilot Lighting before releasing knob.
(Figure 12)
7.
Turn Gas Cock Dial to "ON".
"PILOT" POSITION
"ON" POSITION
"OFF" POSITION
PILOT
+
v
+
+
+
+
v
+
+
+
v
+
PILOT ADJUST
COVER CAP
Figure 12
C2A/B-S (Switch Model) OPERATION
Switch Control Accessory Wiring:
NOTE: Wire length for Thermostat or Remote or
controls should not exceed 20 feet.
Wiring from the Accessory Control (Remote,
Thermostat or Switch) is connected to the two
outside terminals of the Control Selector
Switch as shown in FIGURE 13.
Thermostat wiring should be 20 AWG Type CL2.
Switch Control (Manual ON-OFF):
After successful pilot lighting, allow 60-90 seconds
for Thermogenerator to heat up. To turn burner(s)
on, place Control Selector Switch (FIGURE
11) in the "ON" position. To turn burner(s) off
(pilot remains lit) place Control Selector
Switch in the "OFF" position.
From THERMOPILE
To
ACCESSORY
CONTROL
Valve
Terminals
Control Selector Switch
Figure 13
Outside
Terminal
Piggy
Back
Outside
Terminal
NOTE: Flame size at the burner(s) is adjustable at the Gas Cock Dial (FIGURE 12).