Rasmussen SR-2R Operating Instructions - page 2
REV.5/15/07 Page 2 of 4
STV-10
Valve
STV-LS
Solenoid
LEARN
ADJ.
REMOTE
OFF
Part # BPR-1
Remote Receiver
Receiver
Slide
Button
REMOTE
OFF
SERVO MOTOR
Terminals
RED Wire
1/4” Female
Terminal
BLACK Wire
1/4” Female
Terminal
(Back of Receiver)
BLACK Wire
1/4” Female
Terminal
RED Wire
1/4” Female
Terminal
LEARN
ADJ.
Part # BPR-1
remote receiver houses the microprocessor that responds to commands from the
transmitter to control system operation.
FUNCTIONS:
•
With the slide switch in the REMOTE position, the system will only
operate if the remote receiver receives commands from the
transmitter. Upon initial use, or after an extended period of no use,
the ON/HI button may have to be pressed for up to three seconds
before activating servomotor. If the system does not respond to the
transmitter on initial use, see MATCHING SECURITY CODES in
the GENERAL INFORMATION section.
•
With the slide in the OFF position, the system is off.
•
It is suggested that the slide switch be placed in the OFF position if
you will be away from your home for an extended period of time.
Placing the slide switch in the OFF position also functions as a
safety "lock out" by both turning the system OFF and rendering the
transmitter inoperative.
INSTALLATION INSTRUCTIONS
WARNING
DO NOT CONNECT REMOTE RECEIVER DIRECTLY TO 110-120VAC POWER. THIS WILL
BURN OUT THE RECEIVER. FOLLOW INSTRUCTIONS FROM MANUFACTURER OF GAS
VALVE FOR CORRECT WIRING PROCEDURES. IMPROPER INSTALLATION OF ELECTRIC
COMPONENTS CAN CAUSE DAMAGE TO GAS VALVE AND REMOTE RECEIVER, WHICH
IS NOT COVERED BY WARRANTY.
INSTALLATION
The remote receiver can be mounted on or near the fireplace hearth. PROTECTION FROM EXTREME HEAT IS VERY
IMPORTANT. Like any piece of electronic equipment, the remote receiver should be kept away from temperatures exceeding
130º F inside the receiver case. Battery life is also significantly shortened if batteries are exposed to high temperatures.
NOTE: INSTALLATION IN THE OPTIONAL CERAMIC LOG HOUSE (ITEM#RH2) IS HIGHLY
RECOMMENDED.
WIRING INSTRUCTION
CONNECTING THE RECEIVER TO THE GAS VALVE WITH THE ON/OFF SOLENOID
1. Connect the Black 18 gage stranded wire with the 1/4” female terminal from the receiver to the 1/4” male terminal on the valve
soleniod.
2. Connect the Red 18 gage stranded wire with the 1/4” female terminal from the receiver to the 1/4” male terminal on the valve
solenoid.
3. After receiver wires are connected to the valve solenoid terminals make sure the receiver shield is located over the receiver
and locate the receiver in an area that will not exceed 130° F.
IMPORTANT NOTE: Operation of these controls is dependent on which wire is attached to which terminal. If operation of
control does not correspond to operating buttons on transmitter, reverse wire installation at the receiver or at the control.
NOTE: Up to 6 VDC of pulse power is provided at the receiver terminal.