Rasmussen STR-RMD Installation And Operating Insctructions - page 2
REV.1/30/08 Page 2 of 4
STV-VMD
Motor Drive
STV-10
Valve
Remote Receiver
Receiver
Slide
Button
PULSE MODE
Terminals
RED Wire
1/4” Female
Terminal
BLACK Wire
1/4” Female
Terminal
(Back of Receiver)
BLACK Wire
1/4” Female
Terminal
RED Wire
1/4” Female
Terminal
LEARN
ADJ.
Part # BPR-3
REMOTE
OFF
ON
FUNCTIONS:
•
With the slide switch in the ON position (toward the LEARN button), the system will
remain on until the slide switch is placed in the OFF or REMOTE position.
•
With the slide switch in the REMOTE position (centered), the system will only operate
if the remote receiver receives commands from the transmitter.
•
With the slide switch in the OFF position (away from the LEARN button), the system
is off.
•
It is suggested that the slide switch be placed in the off position if you will be
away from your home for an extended period of time. If the remote receiver is
mounted out of children’s reach, placing the slide switch in the OFF position
also functions as a safety “lock-out” by both turning the system off and
rendering the remote receiver inoperative.
INSTALLATION INSTRUCTIONS
WARNING
DO NOT CONNECT REMOTE RECEIVER DIRECTLY TO 110-120VAC POWER. THIS WILL
BURN OUT THE RECEIVER. FOLLOW INSTRUCTIONS FROM MANUFACTURER OF GAS
VALVE FOR CORRECT WIRING PROCEDURES. IMPROPER INSTALLATION OF ELECTRIC
COMPONENTS CAN CAUSE DAMAGE TO GAS VALVE AND REMOTE RECEIVER, WHICH
IS NOT COVERED BY WARRANTY.
INSTALLATION
The remote receiver can be mounted on or near the fireplace hearth. PROTECTION FROM EXTREME HEAT IS VERY
IMPORTANT. Like any piece of electronic equipment, the remote receiver should be kept away from temperatures exceeding
130º F inside the receiver case. Battery life is also significantly shortened if batteries are exposed to high temperatures.
NOTE: INSTALLATION IN THE OPTIONAL CERAMIC LOG HOUSE (ITEM#RH2) IS HIGHLY
RECOMMENDED.
WIRING INSTRUCTION
CONNECTING THE RECEIVER TO THE GAS VALVE WITH THE ON/OFF SERVOMOTOR
1. Connect the Black 18 gage stranded wire with the 1/4” female terminal from the receiver to the 1/4” male terminal on the valve
servomotor.
2. Connect the Red 18 gage stranded wire with the 1/4” female terminal from the receiver to the 1/4” male terminal on the valve
servomotor.
3. After receiver wires are connected to the valve servo motor terminals make sure the receiver shield is located over the receiver
and locate the receiver in an area that will not exceed 130° F.
IMPORTANT NOTE: Operation of these controls is dependent on which wire is attached to which terminal. If operation of
control does not correspond to operating buttons on transmitter, reverse wire installation at the receiver or at the control.
NOTE: Up to 6 VDC of power is provided at the receiver terminal.
LEARN
ADJ.
Part # BPR-3
REMOTE
OFF
ON