Ray-Dot RVS-22HA Installation Manual - Installation
INSTALLATION
MOUNTING INSTRUCTIONS
The enclosure must be mounted in a location that will
allow the cover to be completely opened right up
against the wall.
Fasten the four brackets to the four mounting holes on
the back of the enclosure, using the four screws
provided with the brackets. Then mount the enclosure
on the wall by inserting screws through the brackets’
adjustment slots, into the wall. Make sure to position
the enclosure so that the power supply cord extends out
of the bottom section of the enclosure.
The bracket slots also serve to adjust the position of the
controller. Once you have adjusted the controller
position, tighten the four mounting screws.
CONNECTIONS
To connect the controller, refer to the wiring diagram enclosed with this installation manual.
1. Set the voltage switch to the appropriate line voltage.
2. Drill access holes on the bottom of the enclosure only. Do not drill holes on the side or
the top of the enclosure.
3. It may be necessary to install a transformer on the heating stage in order to supply the
appropriate voltage to the heating unit.
Alarm Connection
There are two types of alarms on the market. One type sets off when current is cut off at its
input; the other sets off when current is supplied at its input. For the first type of alarm, use the
NO terminal as shown on the wiring diagram. For an alarm of the second type, use the NC
terminal.
a
WARNING
ALL WIRING MUST BE DONE BY AN AUTHORIZED ELECTRICIAN AND
MUST COMPLY WITH APPLICABLE CODES, LAWS AND REGULATIONS. BE
SURE POWER IS OFF BEFORE DOING ANY WIRING TO AVOID
ELECTRICAL SHOCKS AND EQUIPMENT DAMAGE.
RAY DOT
Ventilation Control
Page
7