Ray-Dot RVS-22HA Installation Manual - Installation

Manual is about: Combined Ventilation Controller 4-stage Control for Power Applications 2 variable speed stages and 2 thermo/mister cycle stages

Summary of RVS-22HA

  • Page 1

    Combined ventilation controller rvs-22ha 4-stage control for power applications 2 variable speed stages and 2 thermo/mister cycle stages installation guide read this guide carefully before installing the controller..

  • Page 2

    Do not spray water on the controller. The room temperature where the controller is located must always remain between 32° and 104°f (0° and 40°c). To avoid exposing the controller to harmful gases or excessive humidity, it is preferable to install it in a corridor. Inputs and outputs circuitry is pr...

  • Page 3: Table of Contents

    Table of contents features ................................................................................................................................... 2 control interface ............................................................................................................... 4 cover.....

  • Page 4: Features

    Features the rvs-22ha is a powerful environmental controller that can manage two variable ventilation stages and two on/off ventilation/mist/heater stages. The “room temperature” is the temperature averaged from # 1 to 4 probe readings. A humidity probe may be used to lower the humidity level by act...

  • Page 5

    Rvs-22ha installation guide here is a brief description of the rvs-22ha main features. Digital display a three-digit display provides a high level of accuracy, allowing the user to specify a temperature to within one tenth of a degree (in fahrenheit or celsius units). Pilot lights pilot lights indic...

  • Page 6: Control Interface

    Control interface cover 1 2 3 4 5 13 pilot lig ht s page 4 ray dot ventilation control.

  • Page 7

    Rvs-22ha installation guide item name function digital display displays the value of the parameter selected. Parameter selection knob used to select a parameter. 1 push button a used to access sub-parameters. 2 push button b used to access sub-parameters. 3 adjustment knob used to adjust the value o...

  • Page 8

    Rvs-22ha installation guide dip switches these internal switches, located on the electronic card attached to the back of the cover, are used to set the operating modes described in the table below. When the controller is shipped from the factory, all the switches are set to off. Description the 12 d...

  • Page 9: Installation

    Installation mounting instructions the enclosure must be mounted in a location that will allow the cover to be completely opened right up against the wall. Fasten the four brackets to the four mounting holes on the back of the enclosure, using the four screws provided with the brackets. Then mount t...

  • Page 10

    Rvs-22ha installation guide motor types the relationship between the voltage supplied to a motor and its operating speed is described by a motor type. This type varies with the make and capacity of the motor. The various motors available in the industry have been represented. Select the appropriate ...

  • Page 11

    Rvs-22ha installation guide temperature probes connecting the probes the controller is supplied with one room probe connected to terminal # 1. The probes operate at low voltage and are isolated from the supply. Be sure that probe cables remain isolated from all high voltage sources. In particular, d...

  • Page 12

    Rvs-22ha installation guide to identify the defective probe: set the selection knob to room temp. The room temperature is displayed. Press push-button a or b until the screen displays “pr#” (probe # [number]). If the probe connected to the corresponding terminal is not defective, the screen displays...

  • Page 13: Troubleshooting Guide

    Troubleshooting guide problem cause solution the circuit breaker on the service panel is off or tripped. Reset the circuit breaker. The wiring is incorrect. Correct the wiring. The input fuse is open. Replace the fuse. The voltage selector switch is in the wrong position. Set the switch to the corre...

  • Page 14

    Rvs-22ha installation guide problem cause solution the wiring is incorrect. Fix the wiring. The stage 1 or 2 variable speed fan runs continuously at full speed. The ambient temperature is above the set point + bandwidth. Adjust the set point or bandwidth to the desired value. The selected motor type...

  • Page 15: Technical Specifications

    Technical specifications description value input power 10 w power source (line) 115/230 vac, -20%, +10%, 50/60 hz power fuse 0.125 a @ 250 v, slow blow, 5 x 20 mm stages 3 and 4 10 a @ 125/250 vac 1 hp @ 250 vac ½ hp @ 125 vac stage 1 and stage 2 10 a @ 115/230 vac minimal charge: 25 ma @ 50/60 hz a...

  • Page 16: Factory Settings

    Factory settings position parameter a ↑ b↓ factory setting range of values room temp. Readout — lo — hi — probe 1 readout — probe 1 lo — probe 1 hi — probe 2 readout — probe 2 lo — probe 2 hi — probe 3 readout — probe 3 lo — probe 3 hi — probe 4 readout — probe 4 lo — probe 4 hi — room temp. Room te...

  • Page 17

    Rvs-22ha installation guide position parameter a ↑ b↓ factory setting range of values offset offset/ bandwidth bandwidth 2.0 °f (1.0°c) 0.5 to 20.0 °f (0.3 to 11.0°c) minimum speed 40 10 to 100% de-icing cycle time 1 1 to 720 minutes de-icing on time 0 0 to 900 seconds stage 2 min. Speed motor type ...

  • Page 18: Wiring Diagram

    Wiring diagram page 16 ray dot ventilation control.

  • Page 20

    May22 v1.1.