    0049-0300-xxx miu/powerport series – user guide 08/04/2010 rev. A installation, operation & diagnostics for the miu/powerport series 2.4 / 9.6 / 14.4 / 28.8.

  • Page 2

    0049-0300-xxx miu/powerport series – user guide 08/04/2010 rev. A page i raymar information technology, inc. 7325 roseville road sacramento, ca 95842 800-695-1951 fax: 916-783-1952.

  • Page 3

    0049-0300-xxx miu/powerport series – user guide 08/04/2010 rev. A page ii the products and programs described in this user’s guide are licensed products of raymar-telenetics. This user’s guide contains proprietary information protected by copyright, and this user’s guide and all accompanying hardwar...

  • Page 4

    0049-0300-xxx miu/powerport series – user guide 08/04/2010 rev. A page iii table of contents 1. Standards ...................................................... Page 1 2. Product overview ..................................... Page 2 3. General product specifications....... Page 3 4. Power modes .......

  • Page 5

    0049-0300-xxx miu/power port series – user guide 08/04/2010 rev. A page 1 of 26 1. Standards all raymar-telenetics dial-up modems are designed to meet the following standards: usa: fcc part 15, class a and part 68 canada: doc standards cs-01, cs-02 and cs-03 canadian department of communications not...

  • Page 6

    0049-0300-xxx miu/power port series – user guide 08/04/2010 rev. A page 2 of 26 2. Product overview the miupowerportx.X series are industrial grade dial and leased line modems for connection to the public switched telephone network. They can be powered from a wide range of ac and dc power supplies, ...

  • Page 7

    0049-0300-xxx miu/power port series – user guide 08/04/2010 rev. A page 3 of 26 3. General product specifications dimensions: 5.3 x 4.0 x 1.375 inches weight: 1 lb. Voltage supply: 8 to 24 vdc 7 to 16 vac, 50/60 hz optional wall transformer: 115 vac, 50/60 hz current requirements: (see section 4 for...

  • Page 8

    0049-0300-xxx miu/power port series – user guide 08/04/2010 rev. A page 4 of 26 4. Power modes mode description power consumption power on factory setting : full power is always available to the modem. See section 3 sleep if the modem is on hook for a predetermined period (pe2400 = 5 seconds; pe2496...

  • Page 9

    0049-0300-xxx miu/power port series – user guide 08/04/2010 rev. A page 5 of 26 5. Modem specifications miu2.4 miu9.6 miu14.4 miu28.8 standards v.22bis v.22 bell212a bell 103 v.22bis v.22 bell212a bell 103 v.32bis v.32 v.22bis v.22 bell212a bell 103 v.34 v.32bis v.32 v.22bis v.22 bell212a bell 103 m...

  • Page 10

    0049-0300-xxx miu/power port series – user guide 08/04/2010 rev. A page 6 of 26 6. Power connections dc power jack, 2.0mm – this standard concentric jack is provided to attach an external power source in the range of 7 – 16 vac or 8 – 24 vdc. The 2.0mm jack connects through a full wave bridge so eit...

  • Page 11

    0049-0300-xxx miu/power port series – user guide 08/04/2010 rev. A page 7 of 26 7. Serial data port pin-outs.

  • Page 12

    0049-0300-xxx miu/power port series – user guide 08/04/2010 rev. A page 8 of 26 8. Dip switch settings not applicable – the dip switches are on the pe module. Contact factory for non – standard settings. * note: opening the miu for any reason voids the factory warranty. 9. Led indicator the miu has ...

  • Page 13

    0049-0300-xxx miu/power port series – user guide 08/04/2010 rev. A page 9 of 26 12. Outline drawing & mounting mounting options: part number description miu/mtgk surface wall or panel mounting kit miu/rail miu din rail mounting kit.

  • Page 14

    0049-0300-xxx miu/power port series – user guide 08/04/2010 rev. A page 10 of 26 16. Modem configuration raymar-telenetics dial and leased line modems are based upon rockwell chipsets. These chipsets contain rockwell’s “at” command set. A summary of the rockwell command set for your miu modem is pro...

  • Page 15

    0049-0300-xxx miu/power port series – user guide 08/04/2010 rev. A page 11 of 26 14. Factory configuration ~ miu2.4 active profile: b1 e1 l2 m1 q0 v1 x4 y0 &c1 &d0 &g0 &j0 &l0 &p0 &q0 &r0 &s0 &x0 &y0 s00:001 s01:000 s02:043 s03:013 s04:010 s05:008 s06:002 s07:030 s08:002 s09:006 s10:014 s12:050 s14:...

  • Page 16

    0049-0300-xxx miu/power port series – user guide 08/04/2010 rev. A page 12 of 26 factory configuration ~ miu9.6 active profile: b1 e1 l1 m1 n1 q0 t v1 w0 x4 y0 &c1 &d2 &g0 &j0 &k3 &q5 &r1 &s0 &t5 &x0 &y0 s00:001 s01:000 s02:043 s03:013 s04:010 s05:008 s06:002 s07:050 s08:002 s09:006 s10:014 s11:095 ...

  • Page 17

    0049-0300-xxx miu/power port series – user guide 08/04/2010 rev. A page 13 of 26 factory configuration ~ miu14.4 active profile: b1 e1 l1 m1 n1 q0 t v1 w0 x4 y0 &c1 &d2 &g0 &j0 &k3 &q5 &r1 &s0 &t5 &x0 &y0 s00:001 s01:000 s02:043 s03:013 s04:010 s05:008 s06:002 s07:050 s08:002 s09:006 s10:014 s11:095...

  • Page 18

    0049-0300-xxx miu/power port series – user guide 08/04/2010 rev. A page 14 of 26 factory configuration ~ miu28.8 active profile: b0 e1 l1 m1 n1 q0 t v1 w0 x4 y0 &c1 &d0 &g2 &j0 &k3 &q5 &r1 &s0 &t4 &x0 &y0 s00:001 s01:000 s02:043 s03:013 s04:010 s05:008 s06:002 s07:030 s08:002 s09:006 s10:014 s11:255...

  • Page 19

    0049-0300-xxx miu/power port series – user guide 08/04/2010 rev. A page 15 of 26 15. Diagnostics the following pages provide software and hardware techniques for diagnosing communication problems and thereby isolating the problem at either the local modem, the remote modem or the interconnecting lin...

  • Page 20

    0049-0300-xxx miu/power port series – user guide 08/04/2010 rev. A page 16 of 26 &t2 no function &t3 perform local digital loopback (see figure 3) the modem must be in the command state with connection established when this command is issued, otherwise an error result code occurs. The at&t3 command ...

  • Page 21

    0049-0300-xxx miu/power port series – user guide 08/04/2010 rev. A page 17 of 26 &t6 initiate remote digital loopback (see figure 4) the command is valid only if the modem is in the command state with a connection established. Configure the modem under test with an at&t4 command so that it will hono...

  • Page 22

    0049-0300-xxx miu/power port series – user guide 08/04/2010 rev. A page 18 of 26 enter at&t7 at the local modem and it will send a digital loopback request to the remote modem. After the rdl acknowledgment signal is received from the remote modem, dsr is turned off (if &s1 is in effect), the on-line...

  • Page 23

    0049-0300-xxx miu/power port series – user guide 08/04/2010 rev. A page 19 of 26.

  • Page 24

    0049-0300-xxx miu/power port series – user guide 08/04/2010 rev. A page 20 of 26.

  • Page 25

    0049-0300-xxx miu/power port series – user guide 08/04/2010 rev. A page 21 of 26.

  • Page 26

    0049-0300-xxx miu/power port series – user guide 08/04/2010 rev. A page 22 of 26 additional test / diagnostics commands %l received signal level returns a value (-dbm) which indicates the received signal level at modem data pump interface. This value is determined by the loss/gain of modem telco int...

  • Page 27

    0049-0300-xxx miu/power port series – user guide 08/04/2010 rev. A page 23 of 26 13 other modem did not respond after many transmissions of the same message. Modem made 10 attempts then hung up. 14 protocol violation occurred. 15 compression failure. Note: multiple occurrences may contribute to a no...

  • Page 28: Notes

    0049-0300-xxx miu/power port series – user guide 08/04/2010 rev. A page 24 of 26 notes.

  • Page 29

    0049-0300-xxx miu/power port series – user guide 08/04/2010 rev. A page 25 of 26 raymar information technology, inc. Limited warranty one year limited hardware warranty raymar information technology, inc., dba raymar-telenetics, warrants their products against defects in hardware, material and workm...

  • Page 30

    0049-0300-xxx miu/power port series – user guide 08/04/2010 rev. A page 26 of 26 raymar information technology, inc. Return merchandise authorization (rma) procedure before returning any raymar-telenetics product, an rma number must be obtained. The most convenient way to obtain an rma number for a ...