    0049-1200-xxx rm16m – user’s guide 12/29/2010 rev. C rm16m vdc-r / rm16m vac-r user’s guide.

  • Page 2

    0049-1200-xxx rm16m – user’s guide 12/29/2010 rev. C page i raymar information technology, inc. 7325 roseville road sacramento, ca 95842 800-695-1951 fax: 916-783-1952.

  • Page 3

    0049-1200-xxx rm16m – user’s guide 12/29/2010 rev. C page ii the products and programs described in this user’s guide are licensed products of raymar-telenetics. This user’s guide contains proprietary information protected by copyright, and this user’s guide and all accompanying hardware and documen...

  • Page 4

    0049-1200-xxx rm16m – user’s guide 12/29/2010 rev. C page iii regulatory information fcc requirements this equipment complies with fcc rules part 68. Located on the equipment is the fcc registration number and ringer equivalence number (ren). You must provide this information to the telephone compan...

  • Page 5

    0049-1200-xxx rm16m – user’s guide 12/29/2010 rev. C page iv table of contents 1. Introduction........................................... ………………….Page 1 2. Installation............................................ ……………….…page 5 3. Operation .................................................. …………………....

  • Page 6: Chapter One – Introduction

    0049-1200-xxx rm16m – user’s guide 12/29/2010 rev. C page 1 of 27 chapter one – introduction the raymar-telenetics rm16m universal data shelf tm is a heavy-gauge steel-plated modem rack chassis. It measures 7 inches high and 10.75 inches deep, and mounts in a standard 19- or 23-inch rack. The data s...

  • Page 7

    0049-1200-xxx rm16m – user’s guide 12/29/2010 rev. C page 2 of 27 back panel interface connectors all dte, telco and power connections are made at the back panel of the data shelf. The dte connectors can be: • individual 25-pin modular jacks – one for each pc card (standard) the telco connectors can...

  • Page 8

    0049-1200-xxx rm16m – user’s guide 12/29/2010 rev. C page 3 of 27 single row rj45 connectors dual rows of rj45 connectors figure 1-2. Examples of back panels with 25-pin dte connectors and 8-pin modular telco jacks figure 1-3. Example of back panel with 25-pin eia dte connectors and mass termination...

  • Page 9

    0049-1200-xxx rm16m – user’s guide 12/29/2010 rev. C page 4 of 27 contact information for more information about raymar-telenetics universal data shelves, or other raymar-telenetics solutions, contact us using any of the following methods. Voice mails we welcome your calls at +1 (916) 783-1951, mond...

  • Page 10: Chapter Two – Installation

    0049-1200-xxx rm16m – user’s guide 12/29/2010 rev. C page 5 of 27 chapter two – installation this chapter describes how to install the data shelf. Unpacking and inspecting the equipment unpack the equipment and compare the contents to the packing list. Inspect the equipment for any damage that may h...

  • Page 11

    0049-1200-xxx rm16m – user’s guide 12/29/2010 rev. C page 6 of 27 figure 2-1. Data shelf cabinet installation procedures service personnel should be familiar with the complete installation procedure before installing the shelf. Required tools and equipment special tools or test equipment are not req...

  • Page 12

    0049-1200-xxx rm16m – user’s guide 12/29/2010 rev. C page 7 of 27 mechanical assembly the data shelf mounts into a standard 19-inch cabinet and requires 7 inches of vertical panel space. The 19-inch data shelf also fits into a 23-inch cabinet. This installation requires the rack- mounting brackets t...

  • Page 13

    0049-1200-xxx rm16m – user’s guide 12/29/2010 rev. C page 8 of 27 dc power (rm16m vdc-r data shelf) power for the dc version of the power shelf (rm16m vdc-r) is provided by an incoming power source that connects to ps1, ps2 (or both) on the back of the data panel (see figure 2-4). Facing the front o...

  • Page 14

    0049-1200-xxx rm16m – user’s guide 12/29/2010 rev. C page 9 of 27 digital eia-232 interface the 16 eia-232c or d digital input connectors are labeled and shown in figure 2-6. For a description of the active pin connectors, refer to appendix b. Figure 2-6. Table 2-1 shoes the eia-232 levels from the ...

  • Page 15

    0049-1200-xxx rm16m – user’s guide 12/29/2010 rev. C page 10 of 27 telephone line interfaces the data shelf is fcc certified for connection to the dial-up public switched telephone network (pstn). The following sections describe the standard and optional ways for connecting to the communications lin...

  • Page 16

    0049-1200-xxx rm16m – user’s guide 12/29/2010 rev. C page 11 of 27 • a red 3.5 amp light on the front panel • a 115 or 230 vac connector on the back of the module table 2-3 lists the connector pin functions on the ac power module. Table 2-3. Power connector pin functions pin contact function 1 and a...

  • Page 17

    0049-1200-xxx rm16m – user’s guide 12/29/2010 rev. C page 12 of 27 dc power module the dc power module is a single-slot module designed for the rm16m dcv-r data shelf. The rm16m dcv-r data shelf can hold up to two dc power modules. When two dc power supply modules are used, any loss of supply or ope...

  • Page 18

    0049-1200-xxx rm16m – user’s guide 12/29/2010 rev. C page 13 of 27 removing power modules to remove power modules: 1. Remove the power source from the back of the data shelf. 2. If there is a holding screw on rear of the housing, loosen the screw. 3. Lower the hinged front panel. 4. Grasp power modu...

  • Page 19: Chapter Three – Operation

    0049-1200-xxx rm16m – user’s guide 12/29/2010 rev. C page 14 of 27 chapter three – operation the data shelf accepts leased line, pstn, and dds-type modems. Leased line modems operate on conditioned or unconditioned leased lines. Pstn-type modems operate on the dial-up network and have features that ...

  • Page 20: Chapter Four – Maintenance

    0049-1200-xxx rm16m – user’s guide 12/29/2010 rev. C page 15 of 27 chapter four – maintenance this appendix provides maintenance information for pc cards and power modules. Pc cards if a pc card becomes inoperative, replace it. Field repair is not recommended. Contact raymar- telenetics for instruct...

  • Page 21: Notes

    0049-1200-xxx rm16m – user’s guide 12/29/2010 rev. C page 16 of 27 notes.

  • Page 22

    0049-1200-xxx rm16m – user’s guide 12/29/2010 rev. C page 17 of 27 appendix a – specifications eia standard: compliant with eia standard eia-310-c width: 19 inches (48.3 cm) depth: 10.75 inches (27.3 cm) height: 7 inches (17.8 cm) weight: 20 lbs. (9.1 kg), shipped 50 lbs. (22.7 kg), loaded single sw...

  • Page 23

    0049-1200-xxx rm16m – user’s guide 12/29/2010 rev. C page 18 of 27 appendix b – digital interface descriptions this appendix lists the digital interface descriptions. The information in this appendix may vary, depending on modem type. Consult the manual for the particular pc card you are using. Tabl...

  • Page 24

    0049-1200-xxx rm16m – user’s guide 12/29/2010 rev. C page 19 of 27 pin no. Eia-232c ccitt signal name description 14 sba 141 sec. Transmit data transmitted data on a secondary channel. 15 db transmit clock (dce) a transmit data clock output for use by an external data source. Positive clock transiti...

  • Page 25

    0049-1200-xxx rm16m – user’s guide 12/29/2010 rev. C page 20 of 27 table b-2. Digital interface signal descriptions (232d) pin no. Eia-232c ccitt signal name description 1 101 shield no connection 2 ba 103 transmit data serial digital data (to be modulated) from a data terminal or other digital data...

  • Page 26

    0049-1200-xxx rm16m – user’s guide 12/29/2010 rev. C page 21 of 27 pin no. Eia-232c ccitt signal name description 17 dd 115 receive clock a receive data rate clock output for use by the external data sink. Positive clock transitions correspond to data transition. 18 141 local loopback (loop 3) contr...

  • Page 27

    0049-1200-xxx rm16m – user’s guide 12/29/2010 rev. C page 22 of 27 appendix c – telephone line cables table c-1 lists the function of the modular jacks on the back panel of the data shelf. The figure that follows table c-1 shows a typical telephone-line cable configuration. The last two figures show...

  • Page 28

    0049-1200-xxx rm16m – user’s guide 12/29/2010 rev. C page 23 of 27 figure c-1. Programmable cable 8-pin connector figure c-2. Leased line cable 8-pin connector figure c-3. Example 1: dds cable (cable is also used for dial backup-type modems).

  • Page 29

    0049-1200-xxx rm16m – user’s guide 12/29/2010 rev. C page 24 of 27 figure c-4. Example 2: dds cable (cable is also used for dial backup-type modems) table c-2. Telco connections dsp9612 / mot202t rear panel v.3600 rear panel telco dial telco pin signal direction rj45 rj45 3 ring 1 (input) 3 r1 1 r 6...

  • Page 30

    0049-1200-xxx rm16m – user’s guide 12/29/2010 rev. C page 25 of 27 mass termination connector as an option, a 50-pin mass termination connector may be specified for the telco connection. The adapter for conversion from modular connectors to mass termination also has wire-wrap pins for telco connecti...

  • Page 31

    0049-1200-xxx rm16m – user’s guide 12/29/2010 rev. C page 26 of 27 raymar information technology, inc. Limited warranty one year limited hardware warranty raymar information technology, inc., dba raymar-telenetics, warrants their products against defects in hardware, material and workmanship under n...

  • Page 32

    0049-1200-xxx rm16m – user’s guide 12/29/2010 rev. C page 27 of 27 raymar information technology, inc. Return merchandise authorization (rma) procedure before returning any raymar-telenetics product, an rma number must be obtained. The most convenient way to obtain an rma number for a product purcha...