    Nmea multiplexer owner’s handbook document number: 81250-1 date: february 2005.

  • Page 2

    © copyright raymarine (uk) ltd 2005.

  • Page 3

    I preface congratulations on having bought a raymarine nmea multiplexer. This enables you to combine nmea outputs from up to four devices, to provide a combined output to four other devices. Caution: electrical safety make sure you have switched off the power supply before you start installing this ...

  • Page 4

    Ii for optimum emc performance, it is recommended that wherever possible : • raymarine equipment and cables connected to it are: • at least 3 ft (1 m) from any equipment transmitting or cables carrying radio signals e.G. Vhf radios, cables and antennas. In the case of ssb radios, the distance should...

  • Page 5

    Iii contents preface ........................................................................................ I caution: electrical safety ........................................ I important information ........................................................... I emc installation guidelines .........

  • Page 6

    Iv.

  • Page 7

    1 introduction the raymarine nmea multiplexer combines data from up to four nmea-0183 devices to provide a single, multiplexed nmea output. Inputs & outputs the nmea multiplexer has: • four nmea inputs (listener-ports), nmea in 1, 2, 3 & 4 . • one nmea output (talker-port), nmea out • one common ter...

  • Page 8

    2 nmea inputs each nmea in (listener) port is a differential pair across terminals a and b , and can receive nmea data from one device. The speed of each listener port is fixed at 4800 baud. Nmea data on listener ports 1 and 2 is multiplexed in real time (i.E. Unbuffered). Nmea data on listener port...

  • Page 9

    3 installation mounting as the nmea multiplexer is not waterproof, it must be fitted in a location where it will not come into contact with water. Secure the nmea multiplexer to a suitable surface, as shown in the following illustration. D7556-1 data overflow nmea-0183 multiplex er data overflow nme...

  • Page 10

    4 connections real-time or buffered inputs before connecting nmea inputs to your nmea multiplexer, consider whether they should be connected as real time or buffered inputs: • data running at a fast rate and consisting of single sentences, particularly time-critical data, should be connected to eith...

  • Page 11

    5 nmea out connect the a and b terminals of the nmea out connector to the listening ports of up to four devices to which you wish to transmit multiplexed data. The manner in which the connections nmea out - nmea multiplexer nmea out + device with single-ended nmea output ground nmea multiplexer note...

  • Page 12

    6 are made depends on whether the device has a differential or single ended output, as follows: power supply the nmea multiplexer operates from a dc supply voltage in the range 8 v to 30 v and provides protection against reversed polarity. It is recommended to connect the nmea multiplexer to the sam...

  • Page 13

    7 • 24 awg single-strand wire. • 7/0.2 multi-strand wire, i.E. 7 strands, each of 0.2 mm diame- ter caution: electrical safety before connecting power to the nmea multiplexer, turn off the power supply. Connect either a 24 v or 12 v power supply, via a 0.5 a fuse, as follows: securing cables when yo...

  • Page 14

    8 partially received sentences will be discarded, to ensure that the nmea multiplexer only passes complete and valid sentences. You may be able to resolve this overflow situation if you: • set up the devices on the listener ports to send less data or data at greater intervals. If possible, disable n...

  • Page 15

    9 specifications supply voltage: 8 v to 30 v dc, protected against reversed polarity. Supply protection: 0.5 a fuse supply connection: minimum requirement either: 24 awg single-strand wire. Or 7/0.2 multi-strand wire. Current consumption: 70 ma maximum, with fully loaded talker ports. Inputs: 4 x nm...

  • Page 16

    10 raymarine uk ltd, quay point, northarbour road portsmouth, hampshire po6 3td, united kingdom. Tel: +44 (0) 23 9269 3611 fax: +44 (0) 23 9269 4642 www.Raymarine.Com raymarine inc, 22 cotton road, unit d, nashua, new hampshire 03063-4219, usa. Tel: +1 603.881.5200 fax: +1 603.864.4756 www.Raymarine...