Raymarine ST60+ SPEED INSTRUMENT Owner's Handbook Manual - 2.1 Maintenance

Manual is about: Graphic Display

Summary of ST60+ SPEED INSTRUMENT

  • Page 1

    St60+ speed instrument owner’s handbook document reference: 81261-1 date: december 2005 81261_1.Book page i tuesday, november 29, 2005 12:42 pm.

  • Page 2

    Raymarine, st60+ and seatalk are trademarks of raymarine uk limited © handbook contents copyright raymarine uk limited 2005 81261_1.Book page ii tuesday, november 29, 2005 12:42 pm.

  • Page 3: Preface

    I contents preface important information safety notices emc conformance all raymarine equipment and accessories are designed to the best industry standards for use in the recreational marine environment. The design and manufacture of raymarine equipment and accessories conform to the appropriate ele...

  • Page 4: Product Disposal

    Ii st60+ speed instrument owner’s handbook product disposal waste electrical and electronic (weee) directive the weee directive requires the recycling of waste electrical and electronic equipment. Whilst the weee directive does not apply to some of raymarine's products, we support its policy and ask...

  • Page 5: Contents

    Preface iii preface contents preface ................................................................................................................................ I important information ............................................................................................ I safety notices ...

  • Page 6

    Iv st60+ speed instrument owner’s handbook 1.4 pop-up pilot ......................................................................................................6 1.5 remote control .................................................................................................6 chapter 2: mainten...

  • Page 7

    Preface v caution: protect the power supply ...................................................... 22 3.3 switching on .................................................................................................. 23 warning: calibration requirement .................................................

  • Page 8

    Vi st60+ speed instrument owner’s handbook 81261_1.Book page vi tuesday, november 29, 2005 12:42 pm.

  • Page 9: Introduction

    Preface vii preface introduction thank you for purchasing a raymarine product. We are sure your st60+ instrument will give you many years of trouble-free operation. This handbook describes how to install and use the raymarine st60+ speed instrument. This instrument provides accurate speed, log, trip...

  • Page 10: Remote Control

    Viii st60+ speed instrument owner’s handbook to all other equipment on the seatalk network. A repeater instrument is not directly connected to a transducer but displays information provided by other equipment in the seatalk network. The st60+ speed instrument can fulfil both master and repeater role...

  • Page 11: Parts Supplied

    Preface ix parts supplied unpack your st60+ instrument and check that the following items are present: • item 1, st60+ speed instrument fitted with standard bezel for surface mounting. • item 2, fixing studs (2). • item 3, thumb nuts (2). • item 4, gasket. • item 5, speed transducer, plus bung (not ...

  • Page 12

    X st60+ speed instrument owner’s handbook 1 3 2 4 8 5 3 2 6 7 9 10 st60+ speed instrument owner's handbook d8140-1 speed trip timer reset quick start guide st60+ speed instrument 81261_1.Book page x tuesday, november 29, 2005 12:42 pm.

  • Page 13: Chapter 1: Operation

    1 chapter 1: operation 1.1 getting started displayed information your st60+ speed instrument provides the following: • speed information. • log, trip and water temperature information. • count-up and race-start timers. Switching on and off all the time that power is applied to the instrument, you ca...

  • Page 14

    2 st60+ speed instrument owner’s handbook speed information when power is switched on, the speed button gives you access to current speed, maximum speed, average speed, velocity made good ( vmg ) and speed over ground ( sog ) information. Refer to the speed information flow diagram to access the inf...

  • Page 15

    Chapter 1: operation 3 recorded speed since the last reset. This screen times-out to current speed if no user action occurs for 7 seconds. Average speed the average speed reading is reset at power up. You can also reset it manually by pressing the reset button for 3 seconds. The display shows the av...

  • Page 16

    4 st60+ speed instrument owner’s handbook trip the trip distance is the distance covered since the last reset. It is reset to zero at power up, and if you press the reset button for 3 seconds. Note: the trip distance can be reset only if the instrument is a master, i.E. Connected to a speed transduc...

  • Page 17

    Chapter 1: operation 5 race-start timers you can set each race-start timer to any whole-minute value from 1 to 15 minutes. Note: when the instrument is first installed, the race-start timers are set to 4 and 5 min- utes respectively. To set a race-start timer: 1. Use the timer button as shown in the...

  • Page 18: 1.3 Display Settings

    6 st60+ speed instrument owner’s handbook 1.3 display settings illumination when the instrument is first powered up, the display illumination is set to its lowest level, to facilitate initial access to the buttons. To adjust the illumination level: 1. Hold down the speed button for approximately one...

  • Page 19: 2.1 Maintenance

    7 chapter 2: maintenance & troubleshooting 2.1 maintenance servicing and safety • raymarine equipment should be serviced only by authorised raymarine ser- vice technicians. They will ensure that servicing procedures and replacement parts used will not affect performance. There are no user-serviceabl...

  • Page 20: 2.2 Troubleshooting

    8 st60+ speed instrument owner’s handbook cabling examine all cables for chafing or other damage to the outer shield, and where necessary, replace and re-secure. 2.2 troubleshooting preliminary procedures changes in the electronic environment may adversely affect the operation of your st60+ equipmen...

  • Page 21

    Chapter 2: maintenance & troubleshooting 9 technical support raymarine provides a comprehensive customer support service, on the world wide web and by telephone help line. Please use either of these facilities if you are unable to rectify a problem. World wide web please visit the customer support a...

  • Page 22

    10 st60+ speed instrument owner’s handbook to find out the software version number of your st60+ speed instrument: 1. During normal operation, hold down the speed and trip buttons for approx- imately 4 seconds, to display the version screen. 2. Note the software version number, then hold down the sp...

  • Page 23: Chapter 3: Installation

    11 chapter 3: installation this chapter describes how to install the st60+ speed instrument, and associated speed transducer. The transducer is fitted in the hull of the vessel and signals from it are connected by cable, to the rear of the instrument. The actual type of transducer depends on the typ...

  • Page 24

    12 st60+ speed instrument owner’s handbook other transducer types are also available for specific requirements. For further details, contact your local raymarine dealer. For accurate speed readings the transducer should be sited within the clear water flow areas indicated by the shaded areas in the ...

  • Page 25

    Chapter 3: installation 13 there must also be a viable route for the transducer cable to be routed to the instrument. Instrument st60+ instruments can be fitted either above or below deck, provided the rear of the instrument is sited where it is protected from contact with water. Each instrument mus...

  • Page 26

    14 st60+ speed instrument owner’s handbook emc installation guidelines all raymarine equipment and accessories are designed to the best industry standards for use in the recreational marine environment. Their design and manufacture conforms to the appropriate electromagnetic compatibility (emc) stan...

  • Page 27: 3.2 Procedures

    Chapter 3: installation 15 connections to other equipment if your raymarine equipment is to be connected to other equipment using a cable not supplied by raymarine, a suppression ferrite must always be attached to the cable near the raymarine unit. 3.2 procedures as it is not practical to describe p...

  • Page 28

    16 st60+ speed instrument owner’s handbook surface mounting to surface mount your st60+ instrument (see the surface mounting illustration): 1. Ensure that: • the selected location is clean, smooth and flat. • there is sufficient space behind the selected location to accommodate the rear of the instr...

  • Page 29

    Chapter 3: installation 17 flush mounting the flush mounting kit uses a flush mount bezel to reduce the fitted profile of the instrument, to approximately 0.25 in (6 mm) above the panel fascia. Fitting the flush mount bezel in order to flush-mount your st60+ instrument, you must first replace the st...

  • Page 30

    18 st60+ speed instrument owner’s handbook bezel together. Fit the screws from the rear of the instrument and tighten them sufficiently to secure the instrument and bezel together. Do not over- tighten. Flush mounting procedure flush mount your instrument (see the flush mounting illustration) as fol...

  • Page 31

    Chapter 3: installation 19 4. Cut out the aperture (3) for the assembled instrument and bezel and remove the template. 5. Peel off the protective sheet from the self-adhesive gasket (4) then stick the gasket into position on the rear of the bezel. 6. Screw the two fixing studs (1) into the threaded ...

  • Page 32

    20 st60+ speed instrument owner’s handbook fitting transducer the st60+ speed instrument is supplied, with a through-hull speed transducer. The speed transducer is supplied with detailed instructions for installation and maintenance. Before attempting to install the speed transducer, read these inst...

  • Page 33

    Chapter 3: installation 21 connecting the instrument types of connection the st60+ speed instrument, can be connected: • as a stand-alone, master instrument connected directly to the speed trans- ducer. • as a seatalk repeater. • to fulfil both repeater and master roles by being connected both to th...

  • Page 34

    22 st60+ speed instrument owner’s handbook power supply connections seatalk systems ensure that the power supply for the seatalk bus is protected by a 5 a fuse or circuit breaker. Systems with a large number of instruments on the seatalk bus may require connections to the power supply from each end ...

  • Page 35: 3.3 Switching On

    Chapter 3: installation 23 to fit a power cable: 1. Ensure the intended power source is switched off. 2. Run the power cable from the instrument to a suitable 12 v dc power source. 3. If the cable has not already been trimmed at the power supply end: i. Cut the cable to length and trim back an appro...

  • Page 36

    24 st60+ speed instrument owner’s handbook 81261_1.Book page 24 tuesday, november 29, 2005 12:42 pm.

  • Page 37: Chapter 4: Calibration

    25 chapter 4: calibration 4.1 introduction the st60+ speed instrument is set up with factory-programmed default settings, so in order to optimise the performance of the instrument on board a particular vessel, the procedures in this chapter must be carried out immediately after the completion of ins...

  • Page 38

    26 st60+ speed instrument owner’s handbook set resolution select resolution of either 0.01 or 0.1 as required. Set log units select either nm (nautical miles), sm (statute miles) or km (kilometers), as required. Setting the correct speed set the displayed (current) speed using one of the following m...

  • Page 39

    Chapter 4: calibration 27 user calibration speed resolution speed units set log units hold down for approximately 2 seconds speed trip and + reset timer speed speed speed speed speed if sog available from seatalk if sog not available temperature units timer buzzer pop-up pilot temperature calibratio...

  • Page 40

    28 st60+ speed instrument owner’s handbook adjust cal factor the adjust cal factor screen enables you to manually adjust the calibration factor. It shows the current calibration factor in the top right of the display, and the current speed as large figures (12.4 in the illustration). Use the timer o...

  • Page 41

    Chapter 4: calibration 29 speed calibration this speed calibration procedure involves carrying out two runs over a measured distance, to enable a calibration factor to be determined and applied to your st60+ speed instrument, to ensure optimum accuracy. Each calibration run comprises outward and ret...

  • Page 42

    30 st60+ speed instrument owner’s handbook from intermediate calibration (instrument status display ) this is the end of the first cal run you can now either carry out a second cal run or exit speed calibration calibration run length reset timer + or use either reset timer to set length of calibrati...

  • Page 43

    Chapter 4: calibration 31 5. At the end of the outward leg, press the trip button again so that: • the text return is flashing at the top of the screen. • the displayed distance freezes. Note that this value may not be the same as the measured distance, due to errors introduced by tidal flow. 6. Tur...

  • Page 44: 4.4 Dealer Calibration

    32 st60+ speed instrument owner’s handbook • if you want to carry out a second calibration run: i. Press trip to start the second calibration run (see sheet 2 of the speed calibration flow chart). Ii. Use the procedure described above in steps 4 to 7, to complete the second run. At the end of the se...

  • Page 45

    Chapter 4: calibration 33 response settings the response values for both speed and vmg determine the frequency at which information is updated. A low number provides a smooth response and a high number a much livelier update. Use the timer (decrement) and reset (increment) buttons to set the require...

  • Page 46

    34 st60+ speed instrument owner’s handbook boat show mode ensure that the boat show mode is set to off . If necessary, use the timer or reset button to achieve this. Factory defaults you can use this screen to reset the operating parameters to the factory default values. Use the timer and reset butt...

  • Page 47: Glossary

    35 glossary app apparent ave average awa apparent wind angle (relative to the vessel) aws apparent wind speed btw bearing to waypoint cmg course made good cog course over ground dmg distance made good dtw distance to waypoint emc electro magnetic compatibility eta estimated time of arrival gps globa...

  • Page 48

    36 st60+ speed instrument owner’s handbook m magnetic or meters mag magnetic mob man overboard mph miles per hour nm nautical mile(s) response the sensitivity of an instrument, to data changes rf radio frequency seatalk raymarine proprietary communication system which links products, to provide a si...

  • Page 49: Index

    37 index a average speed , 3 b backlighting adjustment , 6 boat log , 3 boat show mode , 34 boat speed , 2 buzzer , 5 c calibration requirement , 1 , 23 cleaning , 7 condensation , 7 contrast adjustment , 6 d dealer calibration , 32 display setup , 6 disposing of the product , ii e emc information ,...

  • Page 50

    38 st60+ speed instrument owner’s handbook resolution , 26 speed units , 25 temperature reading , 28 temperature units , 28 user calibration access , 32 site requirements instrument , 13 transducer , 11 software version , 10 , 28 speed calibration methods , 26 procedure , 29 speed information , 2 av...

  • Page 51

    Surface mount template for st60+ instruments 1.185 in (30.1 mm) 1.18 in (30.0 mm) surface mount template sun cover edge d8157-1 cut hole 3.54 in (90 mm) diameter drill hole, 3/16 in (5 mm) diameter in 2 positions 1.77 in (45.0 mm) 1.76 in (44.6 mm) remove material from shaded areas only top instrume...

  • Page 52

    81261_1.Book page 40 tuesday, november 29, 2005 12:42 pm.

  • Page 53: Flush Mount

    4.3 in (109 mm) 4.47 in (113.5 mm) sun cover edge instrument edge remove material from shaded area only drill hole, 1/4 in (6.5 mm) diameter in 4 positions top control unit flush mount template flush mount template for st60+ instruments 81261_1.Book page 41 tuesday, november 29, 2005 12:42 pm.

  • Page 54

    81261_1.Book page 42 tuesday, november 29, 2005 12:42 pm.