Raypak 1292 Installation And Operating Instructions Manual - Raypak Commercial

Manual is about: Commercial Swimming Pool Heaters

Summary of 1292

  • Page 1

    Raypak commercial swimming pool heaters part 1: safety warning part 2: models 538 to 4224 part 3: warranty.

  • Page 2: Contents

    3 contents part 1: for your safety this installation and operating instructions manual is provided with the necessary information for the proper installation, operation and maintenance of your raypak heater. Please review and follow these procedures carefully. Keep this manual in a safe and accessib...

  • Page 3: Warning

    Part 1 - for your safety 4 keep this manual in a safe and accessible place for easy reference in the future. This installation and operating instructions manual is provided with the necessary information for the proper installation, operation and maintenance of your raypak heater. Please review and ...

  • Page 4: Caution!

    Part 1 - for your safety 5 ceramic firetile refractory is used in raypak heaters possible risks of irreversible effects harmful by inhalation may be irritating to the skin, eyes and respiratory system. When handling • minimise airborne dust. • wear an approved mask or respirator. • avoid any contact...

  • Page 5: Raypak Commercial

    6 raypak commercial swimming pool heaters part 2: models 538 to 4224.

  • Page 6

    7 part 2 - section i - installation instructions before commencing installation: 1. Read these instructions in full ! 2. Check that the heater you have been supplied is suitable for the type of installation and the gas available. The gas supply pressure must be between the minimum and maximum shown ...

  • Page 7

    Part 2 - section i - installation instructions 8 raypak recommends a minimum length of vertical flue of three (3) metres to ensure correct draft. Outdoor installations. An outdoor heater must not be installed inside any roofed structure or under eaves, roof overhangs, or pool decks. It should also b...

  • Page 8

    9 part 2 - section i - installation instructions pump selection the filtration pump must be sized to provide an adequate water flow for the filtration system and the heater. In some cases however, this can cause a high back pressure which reduces the filtration capacity and in this case it would be ...

  • Page 9

    Commissioning warning: commissioning must only be undertaken by a properly authorised and in some cases appropriately licensed person who is familiar with safe commissioning procedures. The commissioning may require inspection by the gas supply authority, check if this is applicable. Recommended com...

  • Page 10

    To turn off the heater 1. Turn the heater on/off power isolation switch to the "off" position. Emergency shut-down 1. Turn "off" the power supply to the heater 2. Turn "off" the gas isolation valve fitted close to the heater or the main gas supply. After start-up warning should overheating occur or ...

  • Page 11

    Part 2 - section ii - operating instructions location of controls 1. Flame failure reset: this is a combination rest button and indicator lamp. It indicates, when illuminated, that the ignition system has shutdown on its safety control. 2. Alarm fail & mute button: this is an optional extra, which w...

  • Page 12

    13 part 2 - section ii - operating instructions location of controls rl1 mtr12 instructions for use of lae electronic thermostats. Raypak uses the mtr12t1res series thermostats which is programmed to operate in the heating mode. The only adjustments that should normally be required are:- set point (...

  • Page 13

    14 part 2 - section ii - operating instructions models which are connected to a microzone system if the heater(s) are operated by a microzone system, there will be a rotary type control knob fitted which should be aligned to the desired temperature. High limit switch. All heaters are fitted with a m...

  • Page 14

    15 part2 - section ii - operating instructions recommended service procedures it is a raypak requirement that all raypak supplied equipment is serviced at least annually. In some installations, due to the appliance location and/or workload it may be necessary to perform a service every six months. R...

  • Page 15: Warning!

    16 warning! Corrosive water voids warranty for your health and the protection of your pool equipment, it is essential that your water is chemically balanced. For years of trouble-free use of your raypak heater, the following levels may be used as a guide: recommended fibreglass fibreglass other type...

  • Page 16

    17 part 4 - warranty raypak warranty for commercial swimming pool heaters. Raypak australia pty ltd* will: a) repair or, if necessary, replace any raypak pool heater; or b) replace any component (or, if necessary, arrange the installation of a new pool heater), which falls within the warranty period...

  • Page 17

    18 notes.

  • Page 18

    Rheem service 131 031 www.Rheem.Com.Au quality system quality endorsed company manufactured by raypak australia 7 geddes st. Mulgrave vic 3170 ph. (03) 9535 3333 fax (03) 9560 4974 jan 2003 p/no 96209131.