Raypak RHP100 Owners And Installation Manual

Manual is about: RHP Series Swimming Pool and Spa Heat Pump

Summary of RHP100

  • Page 1

    Raypak ® rhp series swimming pool and spa heat pump owner and installation manual this manual should be maintained in legible condition and kept adjacent to the heat pump or in a safe place for future use. For additional information call: (800) 260-2758 manual effective date: 3/1/2003 replaces: all ...

  • Page 2: Caution

    I product safety signs and labels this manual, as well as the pool/spa heat pump itself, contains ansi-approved product safety signs and labels. Please read these signs and labels, as they convey important safety information about hazards that may be potentially present in and around the heat pump. ...

  • Page 3

    Ii rhp series swimming pool and spa heat pump owner and installation manual contents introduction. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 i. Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ....

  • Page 4: Warning

    1 introduction this pool/spa heat pump is an electromechanical machine that incorporates a pressurized refrigerant gas in a sealed system. Only trained and qualified service personnel should attempt to install or service this equipment. Without proper training and knowledge of such equipment, any at...

  • Page 5: Warning

    2 • each side of the unit must be located at least 1 ft from walls, pipes, or other obstructions for unrestricted air intake and service access. Do not install the unit within 3 ft of fossil fuel burning heaters. Air intake along the sides of this heat pump could disturb the combustion process of th...

  • Page 6: Caution

    3 iii. Water connections the heat pump inlet and outlet connections are not interchangeable. They must be connected as instructed below. 1. Connect the heat pump in the return water line between the pool filter and the pool. See page 10, plumbing diagrams. 2. Connect the filter outlet to the fitting...

  • Page 7

    4 indicator lamps: there are 6 indicator lamps located on the unit control panel: • power (amber lamp): when lit, indicates power is applied to the unit. Note: the heat pump will not run when the remote position is selected and there is no remote control system attached. • water flow (green lamp): w...

  • Page 8

    5 note: the heat pump will be off when the remote position is selected on the pool/spa selector switch and there is no remote control system attached. 4.Allow the heat pump to operate for a few minutes to stabilize operating pressures and to allow various component temperatures to normalize. 5. Veri...

  • Page 9

    6 viii. Summer shutdown if you do not plan to use the pool heat pump during the summer months, secure and protect it as follows: 1. From the control panel, turn the control switch to remote (off). 2. Turn the heat pump circuit breaker or disconnect switch to off. 3. Leave the valves set the way they...

  • Page 10

    7 2. B. Cabinet care (optional) - the cabinet is designed for outdoor use and requires little care. However, you can clean it if you wish. 1. 2. Wash the cabinet with soap and water. C. Condensate drainage - the heat pump extracts humidity from the air as it passes through the coil, similar to the w...

  • Page 11

    8 operation. After the desired temperature is reached, return the system to normal operation of 8-10 hours per day. • is airflow through the unit being obstructed? Restrictions such as shrubbery, tall grass, dirty coils, or any other obstruction to airflow will reduce performance. • is the pool blan...

  • Page 12

    9 power supply • verify that all circuit breakers are reset and working properly. • if the power lamp on the control panel still does not light, contact the installing dealer, since it may be a power problem requiring an electrician. Water flow • verify that the filter is clean to provide good flow....

  • Page 13

    10 plumbing diagrams for systems with pumps of less than 2 hp (under 80 gpm), no external bypass is required. Connections are 2-inch pipe slip. Plumb the heat pump after the filter and before any chlorinators. Water in (from pool or spa) water out (to pool or spa) filter for systems with pumps of 2 ...

  • Page 14

    11 heat pump schematic 1 2 34 a b c d 4 3 2 1 d c b a title num b er r evision size a date: 27-jan-2003 sheet of file: c :\pool fact\poofact\poofact.Ddb drawn b y : 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 tb1 control panel interface d4 d ela y a ctiv e d5 a ctiv e d6 pressure ...

  • Page 15

    12 control panel assembly replacement parts list 12 4 7 13 11 10 16 11 9 15 2 5 8 14 3 6 1 item qty description part no. 1 1 control panel 83-10002 2 1 contactor compressor 54-10002 3 1 fan relay 50-10010 4 1 control board 24volt 50-10007 5 1 thermostat 50-10003 6 1 transformer 50-10014 7 1 timer im...

  • Page 16

    13 control panel cover assembly replacement parts list 1 4 4 4 7 6 7 6 8 8 5 front item qty description part no. 1 1 control panel cover 81-30152 2 2 pot 50-10004 3 1 switch type a403 50-10005 4 3 knob 56-10001 5 1 label control panel 84-10017 6 2 lamp green 53-10001 7 2 lamp red 53-10003 8 2 lamp a...

  • Page 17

    14 heat pump assembly replacement parts list - rhp 100 11 15 13 12 5 9 18 2 7 7 7 6 8 1 4 10 3 17 14 9 19 rhp 100 16 0207 *see assembly drawing in this manual item qty description part no. 1 1 assembly base 81-20140 2 1 evaporator coil 40-10002 3 1 access panel 81-50141 4 1 power input panel 81-4015...

  • Page 18

    15 heat pump assembly replacement parts list - rhp 115 11 15 13 12 5 9 2 9 16 7 7 18 14 6 7 3 17 19 4 10 1 8 rhp 115 *see assembly drawing in this manual item qty description part no. 1 1 assembly base 81-20140 2 1 e vaporator coil 40-10002 3 1 access panel 81-50141 4 1 power input panel 81-40151 5 ...

  • Page 19

    16 11 12 15 13 18 9 2 16 9 7 7 7 6 8 1 4 3 17 14 10 19 5 *see assembly drawing in this manual rhp 160 ite m qty description part no. 1 1 assembly base 81-20140 2 1 e vaporator coil 40-10003 3 1 access panel 81-50142 4 1 power input panel 81-40152 5 1 cover, top 81-10140 6 1 compressor, scroll 30-100...