Rion NL-62 Quick Instruction Manual

Manual is about: Sound Level Meter

Summary of NL-62

  • Page 1

    Sound level meter nl-62 quick instruction manual (ver.1.0) rion co., ltd. Technical support division, sound and vibration measuring instruments business department november 9 th , 2012 hu0-01 sound level meter (with low-frequency sound measurement function) class 1 nl-62.

  • Page 2

    1 contents 1 controls and functions ...................................................................................................................................... 3 1-1. Front panel, operation key panel ............................................................................................

  • Page 3

    2 9-4. Key lock .................................................................................................................................................. 40 9-5. Eco setting (power-saving mode) ....................................................................................................

  • Page 4

    3 1.controls and functions 1-1.front panel, operation key panel this sound level meter has the following display and key panel. Several settings such as frequency weighting, time weighting and other parameters for measurement are set from the menu list. The display supports various languages, and en...

  • Page 5

    4 1-2.input/output connectors a variety of i/o connections 1-3.measurement screen display the illustration below shows all elements of the display for explanation purposes. In actual operation, such a screen will not be shown..

  • Page 6

    5 2.preparations 2-1.power on/off power on : hold down the power key until the power-on screen appears (at least 1 second). Power off : hold down the power key until the unit is turned off (several seconds). 2-2.menu list screen ① when the measurement screen is displayed, pressing the menu/enter key...

  • Page 7

    6 especially when the unit is connected to a level recorder, data recorder or frequency analyzer, it is necessary to consider the dynamic range. For example, when the unit is connected to a level recorder, whose dynamic range is maximum 50 db, if the full scale output of the unit is set to 130 db, t...

  • Page 8

    7 2-6.internal calibration (electrical calibration) before and after a measurement, the unit must be calibrated. Calibration is carried out using a signal generator (1 khz, sinusoidal wave) built into the unit. The procedure for internal calibration is described below. ① press the cal key. Verify th...

  • Page 9

    8 ⑥ verify that “acoustic calibration” is displayed in the upper part of the screen. If “internal calibration” is shown in the upper part of the screen, press the display key. The calibration mode will change to “acoustic calibration”. Use the △/▽ keys to adjust the reading of the nl-62 to the value...

  • Page 10

    9 2-8.setting of the frequency weighting and the time weighting ① press the menu/enter key to bring up the menu list screen. ② on the touch screen, select the frequency weighting characteristic for the main channel. Each press on the “freq” field with the finger cycles through the following settings...

  • Page 11

    10 3.measurement 3-1.sound level measurement ① press the menu/enter key and select the frequency weighting characteristic on the touch screen. ② set the frequency weighting as described below. ・a-weighted sound pressure level: “a” setting. ・c-weighted sound pressure level: “c” setting. ・z-weighted s...

  • Page 12

    11 on or off 3-2.store operation (1) manual mode store operation all processed data except sound level are considered as a single data set, and the operator stores the data sets one-by-one manually. When the operator performs the store operation after a measurement, each processed value and measurem...

  • Page 13

    12 ③ bring up the menu list screen and select [store]. Manual mode setting is as follows. The store name only appears when a sd memory card is inserted. Setting item setting store mode manual store name number of four digits measurement time 10 s / 1 min / 5 min / 10 min / 15 min / 30 min / 1 h / 8 ...

  • Page 14

    13 ④ back to the measurement screen, the currently selected address is shown on the screen. The △/▽ keys can be used to specify the address in the range from 0001 to 1000. (if the address is shown in red, it already contains data. Take care not to overwrite data that you want to keep.) ⑤ press the s...

  • Page 15

    14 (2) auto mode operation an sd memory card should be inserted in the card slot. The data will automatically be stored on the card. With the auto mode, l p store and l eq store are executed simultaneously (separate operation is also possible). ・ l p store this is useful when recording the sound lev...

  • Page 16

    15 on or off ● the procedure for auto store operation is as follows: ① measurement settings as described in chapter “3-1 sound level measurement” must be completed beforehand. ② to select the measurement values l eq , l e , l max , l min and l n (n = 05, 10, 50, 90, 95)you want to display, set the d...

  • Page 17

    16 ④ press the start/stop key to start the measurement. While the measurement is in progress, the symbol flashes and the elapsed time is displayed. In addition, the indicator led flashes red. The measurement values will be stored on sd memory card automatically at every interval set for the l eq cal...

  • Page 18

    17 on or off (3) timer auto mode operation ● about timer auto mode operation an sd memory card should be inserted. Auto store is executed using a set start time, stop time and, if set, a timer auto interval. Refer to the figure below. With the timer auto mode, l p store and l eq store are executed s...

  • Page 19

    18 timer auto mode number of four digits l p store interval l eq processing interval start time stop time timer auto interval sleep mode ③ bring up the menu list screen and select [store]. Make the settings as follows: setting item setting store mode timer auto store name number of four digits l p s...

  • Page 20

    19 while the measurement is in progress, the symbol flashes and the elapsed time is displayed. In addition, the indicator led flashes press the start/stop key to start the measurement while the measurement is in progress, the symbol flashes and the elapsed time is displayed. In addition, the indicat...

  • Page 21

    20 4.data recall 4-1.recalling stored data on the screen of the sound level meter ● about data recall this is the function to read out the stored data from the internal memory or sd memory card. ● the procedure is as follows: ① press the menu/enter key and select [recall] on the menu list screen. Th...

  • Page 22

    21 ・ recall screen of l p store data in auto mode.(sd auto l p ) (a) numeric screen of l p store data (b) time-level screen of l p store data press the display key, the screen will switch to time-level screen. ・ recall screen of l eq store data in auto mode.(sd auto l eq ) ⑥ pressing the pause/cont ...

  • Page 23

    22 4-2. recalling stored data on a computer ● outline stored data can be recalled on a computer. The unit will be recognized as a removable disk when connected to a computer. To make the connection, use a generic usb cable (standard a male to mini b male connector). In this case, select [i/o] from t...

  • Page 24

    23 ● the procedure to open data in spreadsheet software is as follows: ① start spreadsheet software (for example excel) and click “file open”. ② select the folder containing the data file, make sure to select “all files” at file type. ③ select a stored data file displayed in the dialog box and click...

  • Page 25

    24 ⑥ the selected data file will be opened. 《manual store data, opened in excel》 《auto store l p store data, opened in excel》 《auto store l eq store data, opened in excel》.

  • Page 26

    25 5.delay time, pause, back erase 5-1.delay time ● outline a delay in starting a measurement from the point of pressing the start/stop key can be set. This function is useful for excluding the operating sound made when pushing the start key or the sound of the operator's footsteps. Refer to the fig...

  • Page 27

    26 5-2.pause, back erase ● outline note: only when the store mode is manual, the pause and back erase functions are available. When the store mode is auto or timer auto, these functions are not available. ・ pause during a measurement, the pause/cont key can be used to exclude unwanted events from pr...

  • Page 28

    27 ● the procedure for setting the back erase time is as follows ① select [store] from the menu list and select [store mode]. Select the manual mode. (when the store mode is auto or timer auto, the pause and back erase functions are not available.) ② select [measure] from the menu list and select [b...

  • Page 29

    28 6.marker ● outline when the store mode is set to auto or timer auto, and the l p store interval is specified, a marker can be added to the data. Pressing △ key or ▽ key will add the corresponding marker to the data. If the marker is added to a target event, the marker helps to distinguish between...

  • Page 30

    29 7. Sub channel and additional processing value measurement ● outline when the sub channel is set to on, the sub channel l p value can be displayed with the main channel l p value on the measurement screen. When the sub channel is set to on, one of the following additional processed quantities is ...

  • Page 31

    30 ※ caution ・ when data store is executed with the sub channel set to on and the additional processing function set to on, the main processing values and the additional processing values are saved as manual stored data or auto stored l eq data. All the stored data can be displayed by the recall ope...

  • Page 32

    31 8. Waveform recording function ● outline when the waveform recording program nx-42wr is installed, this function enables users to record a sound pressure waveform on sd card as a wave file of pcm form, together with the stored numerical data. The recorded wave files can be played on computer and ...

  • Page 33

    32 ■ playback and analysis of recorded files ・playback of recorded files recorded files can be played with wave file playback software (on public sale) or with the waveform analysis software da-20pa1, da-40viewer or as-60 from rion. Playback on the nl-62 is not possible. ・analysis of recorded files ...

  • Page 34

    33 ● store format of waveform recording data ■ store destination folder files are saved in the sub folder sound which is created in the store folder specified by the store name. Example: manual_0123/sound (with manual store) auto_0123/sound (with auto store) ■ file name of waveform recording data.

  • Page 35

    34 8-1. Manual recording ● outline manual recording allows recording of the sound pressure waveform for any duration during auto store operation. This type of recording is suitable when the operator is able to control the recording function manually as necessary. ● operation procedure ① set [store m...

  • Page 36

    35 8-2. Level recording ● outline when level recording is set to “on”, recording executes while the level exceeds the trigger level. It is used in order to record only high sound levels. ● operation procedure ① set [store mode] in the store menu list screen to “auto” or “timer auto”, and make the re...

  • Page 37

    36 ※note ・ when the maximum recording time is set to “off”, files are divided at 1 hour. ・ when the maximum recording time is set to 10 minutes, recording will stop after 10 minutes, also when sound still continues to exceed the trigger level for a longer time (such as the sound of an idling car). T...

  • Page 38

    37 8-3. Interval recording ● outline when interval recording is set to “on”, recording starts at preset intervals. The interval is can be selected as 10 or and 1 hour. The recording time can be selected as 15 seconds or 1 minute. This function can be used to record environmental sound on certain fix...

  • Page 39

    38 8-4. Total recording ● outline of total waveform recording in auto store mode, the sound waveform will be recorded continuously during measurement. In manual store mode, the sound waveform is recorded during the entire measurement and stored after finishing the measurement. ● operation procedure ...

  • Page 40

    39 ・ in case of auto store or timer auto store when you press the start/stop key to start auto store, waveform recording also starts simultaneously. Files are created and saved for each recording period. To stop recording, press the start/stop key. During auto store, the pause/cont key (pause functi...

  • Page 41

    40 9-4. Key lock pressing the and keys together activates the key lock. A lock symbol appears in the bottom left corner of the display, and the operation keys except for the light key are disabled. If a key other than the light key is pressed, a key lock indication appears. Pressing the and keys tog...

  • Page 42

    41 10. Menu lists 10-1. Nl-62 menu list items 10-2. Nx-42wr menu list items.