• Byusingthespeedselector
,youcansetthespeedofthefan:
FastSpeed: Hi
SlowSpeed: Low
Timer operation
Byusingthebutton
,theusercanprogramaperiodofoperationbetween1hand24h.At
the end of the programmed period the device stops completely.
Duringthetimerperiod,thedisplayshowsthetimeprogrammed,andtheindicator
is illu-
minated, indicating that the device is programmed to function for a limited time period.
Self-defrost cycle
Thenormaloperatingtemperaturerangeis+5ºC/+32ºC.Operationofthedeviceoutsidethis
range is not recommended.
Theself-defrostfunctionisinitiatedautomaticallybythedeviceitself.Itisactivatedforaperiod
of5minutesiftheambienttemperatureisbelow15ºCapproximately.Whenthisfunctionis
activated, the self-defrost indicator light
illuminates.
Self reset function
Thedeviceisequippedwithaselfresetfunction.Intheeventthatthepowersupplyiscut
temporarily for any reason, the unit resets itself automatically, retaining the parameters set by
theuserbeforethepowercut.
REMOVAL OF WATER
Removal of water by means of the tank
1.Anintermittentsoundsignalaccompaniedbytheilluminationoftheredlight
, indicate
thatthewatertankisfull.Thedevicewillceasetooperateuntiltheuseremptiesit(Fig.3).
2.Onceemptied,replaceitinsidetheunit.Whentheindicator
goes out, this indicates that
the tank has been replaced correctly.
Precautions: Donotremovethetanktoooften.Ifthisactionisrepeatedoveraseriesofshort
periods,damagecanbecausedtothecompressor.Waituntilthetankiscompletelyfull.
Continuous water drainage
1.Removethewatertank,sothatyoucanconnectthepipetothewateroutlettube(Fig.3).
2.ConnectaPVCpipewithaninteriordiameterof14mmtothewateroutlettubeandsecure
itwithanylonhoseclip.Theextractiontubemustalwaysbeflattothefloorandfreeofany
kinkthatmightobstructtheflowofwater.
3.Replacethewatertankintheunit,andthelatterwillrestartoperatingafter3minutesap-
prox.