S.R.Smith WetDek Installation Instructions And Owner's Manual

Manual is about: S.R. Smith WetDek splash pad

Summary of WetDek

  • Page 1

    06-901 © s.R. Smith llc 2008 dec09 wetdek corporate headquarters western sales and manufacturing plant p.O. Box 400 ● 1017 sw berg parkway canby, oregon 97013 (503) 266-2231 ● fax (503) 266-4334 www.Srsmith.Com installation instructions and owner’s manual.

  • Page 2

    2 introduction the wetdek is designed for use as a residential splash pad. Proper installation, use, and maintenance are essential for optimal performance and to reduce the risk of accident or injury. These instructions are developed and intended for use with either the stand alone or poolside versi...

  • Page 3

    3 (1) (2) (3) (4) (5) (7) (9) (10) (6) (8) wetdek parts list poolside stand alone item no. Qty. Part no. Description x x 1 1 30011 wetdek aquadirector controller x x 2 6, 9, 12 31000 brass nozzles x x 3 4 30005 1” hpv valves x x 4 4 30006 1” valve manifold tee x x 5 1 30007 1” globe valve x x 6 1 30...

  • Page 4

    4 wetdek installation guidelines the wetdek can be installed as a stand alone product or as a poolside feature. Each model requires variations in installation. There is also a section of common installation requirements and a section for optional additions that can be added to the system. Backyard s...

  • Page 5

    5 5. The middle fitting is designated for the recirculation/bypass line returning from the valve manifold. 6. The top fitting on the reservoir should be connected as an overflow pipe or as an auto-fill. If used as an overflow pipe, it should run to a french drain or other overflow area. 7. The ¾ hp ...

  • Page 6

    6 poolside model 1. The proper layout for the wetdek poolside plumbing is located in figure 5. 2. The poolside version of the wetdek should run off of an independent pump from the rest of the pool. This independent pool pump will need to provide the following gallons per minute (gpm): a six nozzle m...

  • Page 7

    7 9. It is also important to insure that the valves are all in the same orientation before attaching the manifold tees (4) as shown in figure 6. 10. The manifold tees (4) should first be wiped with a pvc primer and then given a liberal amount of pvc glue on one of the surfaces before connecting the ...

  • Page 8

    8 optional installation add-ons the following items are not provided with your wetdek kit but can be purchased additionally from many local suppliers. 1. Additional globe valves: to help control the height of each individual zone it is required that a 1” globe valve (5) be placed after each 1” hpv v...

  • Page 9

    9 4. Auto-fill: another optional item for the stand alone version of the wetdek, an auto-fill can be attached to the top 1 ½” fitting on the reservoir to regulate the water level in the tank, as shown in figure 10. This is recommended for wetdeks located in hot climates where evaporation will have a...

  • Page 10

    10 1. Figure 11 shows the internal wiring for the wetdek aquadirector controller. The wetdek controller is manufactured to handle 120v input; this diagram shows how to install the standard configuration for 120v power. Please read this section carefully to prevent damage to the circuit board. All ci...

  • Page 11

    11 the following images show the pipe layouts for the nozzles for various pad configurations. These are some stock examples, but custom designs are encouraged to give each project a unique feel. Nozzles should be divided evenly amongst the three zones (two nozzles per zone for a 6 nozzle kit, three ...

  • Page 12

    12 pad size a* b* 12’ x 12’ (6 nozzles) 24 84 14’ x 14’ (9 nozzles) 36 108 16’ x 16’ (12 nozzles) 48 132 table 3 *all dimensions given in inches figure 14.

  • Page 13

    13 pad size a* b* c* 12’ x 8’ (6 nozzles) 96 6 24 14’ x 10’ (9 nozzles) 120 12 36 16’ x 12’ (12 nozzles) 144 18 48 table 4 *all dimensions given in inches figure 15.

  • Page 14

    14 operating the controller the control box that operates the wetdek has three buttons, which are used to control the system, and four lights, as well as a four digit numerical display. The three buttons are labeled “sel”, “inc/+”, and “dec/-“. The four lights are labeled “program select”, “run time...

  • Page 15

    15 wetdek care & maintenance there are a couple of areas of the wetdek that require regular maintenance: water, plumbing, and the pump. Routine checks will help prolong the life of all components of the wetdek. Water testing it is recommended that you test your wetdek water regularly with an accurat...