S2P KS2P-18A31 Owner's Manual

Manual is about: EVAPORATIVE AIR COOLER

Summary of KS2P-18A31

  • Page 1

    Evaporative air cooler 1 11. 26 owner’s manual read and save these instructions read all instructions carefully before setting up and operating this unit. This manual is designed to provide you with important information needed to setup, operate, maintain, and troubleshoot your cooler. Failure to fo...

  • Page 2

    Evaporative air cooler 2 11. 26 preface we really appreciate you credit and support in advance. Our evaporative air cooler will bring you breeze health with least energy. Adopting the most advanced evaporative cooling technology in the world and the contemporary production management system, this in...

  • Page 3

    Evaporative air cooler 3 11. 26 evaporative air coolers features (1) well designed system ensures best cooling effect; (2) energy efficient and environmental friendly saving more than 80% of electricity as compare with conventional air conditioners; (3) the patented filter pad has over 90% of soak r...

  • Page 4

    Evaporative air cooler 4 11. 26 spare parts main components: motor:  high efficiency, low noise, strong power volume  full protection against over current, over voltage and overload  unsurpassed reliability water level probe:  water level control  precisely and accurately checks the water level...

  • Page 5

    Evaporative air cooler 5 11. 26 drain valve:  automatic water draining every 8hours  prevents algae growth  maintains clean unit  clean and dry function inlet valve:  new type, smart designed, permanent magnetic valve  small buoy, unsurpassed reliability water pump:  professionally manufactur...

  • Page 6

    Evaporative air cooler 6 11. 26 important notes 1. The best effect is achieved when the unit is used in a well ventilated and dry place, where the unit takes in 100% fresh air from outside and no re-circulation occurs. 2. Avoid discharging cool air into an closed space. There must be enough space fo...

  • Page 7

    Evaporative air cooler 7 11. 26 (1) wall: (2) roof:.

  • Page 8

    Evaporative air cooler 8 11. 26 (3) diagram of bracket:.

  • Page 9

    Evaporative air cooler 9 11. 26 (4) diagram for duct adaptor notes: as shown above the four installation holes at the bottom of the cooler are fixed on the four steel tubes welded on the bracket to the cooler from moving out of place..

  • Page 10

    Evaporative air cooler 10 11. 26 circuit diagram of control box of ks2p-18a31 tips for better duct work (1).The duct uses zinc coated steel, glass steel and plastic duct also can be used. (2).The air diffuser should be installed in the places where the temperature actual need to be cooled. It depend...

  • Page 11

    Evaporative air cooler 11 11. 26 (5).The air duct should not be too long, the maximal length is 20m. (6).Keep the duct in a straight line is much better. To reduce the pressure drop, some unnecessary elbow and branch should be refrained. (7).Try to use motor driven diffuser in the plane layout. The ...

  • Page 12

    Evaporative air cooler 12 11. 26 picture 2-1show the current time picture 2-2 change hours picture 2-3 change minutes 3. Fan (note: ks2p-18a31 do not support exhaust function) the button is used to select vent(fresh air been delivered into rooms, but the air doesn ’t been cooled). Press button can t...

  • Page 13

    Evaporative air cooler 13 11. 26 picture 3-1 turn on vent picture 3-2 turn on exhaust 4. Cool cool function will make the pump to work, take out water from tank to wet cooling pad. Cooled air will be delivered. Press button can turn on and turn off cool unction. When you press button, if the water l...

  • Page 14

    Evaporative air cooler 14 11. 26 will pause automatically to protect pump, and running again when drain stop and water filled enough. Picture 5-1 turn on vent, cool and clean 6. Auto-cleaning when fan and cool functions work together for n hours(n can be set), air cooler will open the clean function...

  • Page 15

    Evaporative air cooler 15 11. 26 press button can turn on and turn off swing unction. Picture 7-1turn on vent, cool, and swing 8. Timer can turn on/turn off the timing function, the wall controller will work according to the last setting before shutdown. Timer function can work on any working modes,...

  • Page 16

    Evaporative air cooler 16 11. 26 picture 8-1timing turn on picture 8-2 setting hours picture 8-3 setting minutes picture 8-4finish the setting 8.2 timing turn off the processes are as follows: 1)press the button, and the screen will show “18:40”, “on” is flashing, means the machine will be turned on...

  • Page 17

    Evaporative air cooler 17 11. 26 picture 8-5 setting of timing turn on picture 8-6 setting of timing turn off picture 8-7 setting hours picture 8-8 setting minutes picture 8-9 finish the settings of timing turn on/off 8.3 cancel timing the processes are as follows: 1)press the button, the screen sho...

  • Page 18

    Evaporative air cooler 18 11. 26 4) press button, timing function been canceled, the screen just shows current time 18:35, no any timing setting. Picture 8-10 setting of timing turn off picture 8-11 cancel the setting picture 8-12 timing function been cancel 9. Mode ( ks2p-18a31 do not support rtc) ...

  • Page 19

    Evaporative air cooler 19 11. 26 press button for 3 seconds, can switch air c ooler’s working modes, that is manual, auto℃, auto%. 9.1 manual mode with the wall controller on, press the button until manual is shown on the top left corner of screen. Current temperature and relative humidity will be s...

  • Page 20

    Evaporative air cooler 20 11. 26 picture 9-5 finish the setting 9.3 auto% mode under the mode of auto%, the wall controller will adjust fan speed and pump’s work to maintain the relative humidity. When the mode switch to auto%, the icons of auto%, fan and cool will be shown on screen, fan and cool f...

  • Page 21

    Evaporative air cooler 21 11. 26 picture 9-8 finish the setting 10. Pre-cooling mode if your wall controller is designed to allow for the saturation of the cooler’s cooling pads before the fan is switched on. The default of pre-cooling mode is closed. On the state of shutdown, press the buttons of a...

  • Page 22

    Evaporative air cooler 22 11. 26 picute10-3 pre-cooling function is running 11. Intelligent cleaning mode (note: ks2p-18a31 do not support this feature) note: this feature does not apply to all machines, it will be taken effect only for evaporative air coolers with exhaust function. We suggest you c...

  • Page 23

    Evaporative air cooler 23 11. 26 12. Shutdown cleaning mode if your wall controller is designed to shutdown cleaning mode, the cooler will open the clean function automatically when shutdown. The default of shutdown cleaning mode is closed. On the state of shutdown, press the button of and for 5 sec...

  • Page 24

    Evaporative air cooler 24 11. 26 picture 14-1 over-current e2 ”e2” flashing indicates, the voltage supply to air cooler is over-voltage (more than 265v). Please break the power off, and check the power supply. E3 ”e3” flashing indicates, the voltage supply to air cooler is under-voltage, (lower than...

  • Page 25

    Evaporative air cooler 25 11. 26 water and power supply (1).The water must be clean, tap water is often used and water source pressure should more than 1.0kgf/cm. (2).There should be a stop valves in the hose and obligate a pine joint. (3).Keep the voltage only between 210-250v. (4).There should be ...

  • Page 26

    Evaporative air cooler 26 11. 26 troubleshooting the following troubleshooting guide is intended to address the most common symptoms and is by no means exhaustive. If symptoms persist, call a qualified serviceman. Only a certified electrician should complete electrical work. Turn off all power to th...