Sacred Sun sp series Technical Manual

Summary of sp series

  • Page 2: Contents

    Contents security instruction ..............................................................................................................01 chapter one product introduction 1. Product characteristics ....................................................................................................

  • Page 3: Curity

    Se curity instr uction security instruction please read these instructions carefully in order to make correct, safe, and effective operation. This manual provides you with very important installation and operation guidelines, which will guarantee 01 your equipment an optimal performance and longer s...

  • Page 4: Prod

    Prod uct int roduc ti on chapter one product introduction product characteristics 02 basic characteristics agm valve regulated technology, high-tin-low-calcium multielement special alloy, poor electrolyte design, negative adsorptive theory, restrain hydrogen separate out effectively, reduce the elec...

  • Page 5: Prod

    Prod uct int roduc ti on main applications ups/eps 03 telecommunication and power supply equipment security system alarm system medical treatment electrical tool portable instrument signal light solar and wind energy storage battery structure.

  • Page 6: Prod

    Eight (kg) 2.15 2.4 2.7 3.6 5.30 8.0 8.0 10.5 9.5 12.0 13.5 12.9 16.1 20.5 21.7 23.2 29.8 36.0 42.5 59.0 61.9 69.6 w otal height 98 98 98 100 166 125 125 163 175 170 170 170 201 175 175 179 223 231 240 223 237.5 225 t ) mm height 94 166 125 125 158 175 165 170 165 201 175 175 179 215.5 222 240 218 2...

  • Page 7: Prod

    2 2 4 2 4 4 2 2 prod uct int roduc ti on working principle the electrochemical reaction of batteries in charge and discharge process as follows: 05 discharge pbo 2 +2h 2 so 4 + pb pbso 4 + 2h 2 o + pbso 4 charge in the final stage of charge process, active substance in positive plate transformed to ...

  • Page 8: Ech

    T ech nical cha racteri stics chapter two technical characteristics discharge curve 06 all series common curves figure 2-1 discharge capacity and temperature curve figure 2-2 discharge capacity and storage time curve.

  • Page 9: Ech

    T ech nical cha racteri stics all series characteristic curves figure 2-3 discharge characteristic curve under different discharge rates(25 ℃) 07 3c figure 2-4 cycle times and depth of discharge curve.

  • Page 10: Ech

    T ech nical cha racteri stics charge curve 08 figure 2-5charge characteristic curve peace) charge figure 2-6 floating charge service life characteristic curve---below 24ah batteries v/cell.

  • Page 11: Ech

    T ech nical cha racteri stics figure 2-7 floating charge service life characteristic curve---24ah and above batteries 09 v/cell.

  • Page 12: Ech

    T ech nical cha racteri stics 10 internal resistance and short circuit current the internal resistance is dynamic nolinear parameter, it continuously varies with the temperature, charge state and service duration. The internal resistance is the lowest when the battery is fully charged. Below tables ...

  • Page 13: Operati

    Operati on and maint ena nce chapter three operation and maintenance parameters 11 ambient temperature is -15 ℃~45℃ and the optimal operation temperature is 25℃±5℃. Ambient humidity less than rh92% altitude less than 4500m,if operation altitude more than 4500m,please make special reminder when confi...

  • Page 14: Operati

    Operati on and maint ena nce figure 3-1 service life and temperature curve---sp series 18 figure 3-2 service life and temperature curve---ssp series 12.

  • Page 15: Operati

    Operati on and maint ena nce charge floating charge 13 charge method: 2.27v / cell with limited current of 0.3 c 20 (a). Charge voltage should be adjusted according to ambient temperature,temperature compensation coefficient is -3mv / cell / ℃. Floating charge voltage at different ambient temperatur...

  • Page 16: Operati

    Storage temperature the interval of supplementary charge methods(choose either one) below 25 ℃ per 6 months charge with 0.25c a limited current and 2.27v/cell 20 constant voltage for 2~3 days. Charge with 0.25c 20 a limited current and 2.45v/cell constant voltage for 10-16 hours. 25~30 ℃ per 4 month...

  • Page 17: Operati

    Operati on and maint ena nce check whether safety valve is twisted tightly or not perform a discharge test to check the exact load every year, discharge 30%-40% of the rated capacity. 15 three yearly maintenance after three years operation,battery capacity should be tested,if battery bank actual cap...

  • Page 18

    No.1,shengyang road,qufu city,shandong province,273100,p.R.China tel:0086-537-4438666-6028 fax:0086-537-4411936 e-mail:sales@sacredsun.Cn.