Saey 194 Installation And Operation Manual - page 15
15
Airbox System: the combustion air is supplied via 1 opening on the stove and
distributed via airducts inside the stove. An airbox can be mounted on the air inlet.
On this inlet, you can mount a tube with a diameter of 100mm. When using smooth
tubes, you can connect up to 12 meters of tubes. When applying accessories such
as elbows, you need to reduce the maximum length of 12m by 1 meter per
accessory (e.g. 10m tubing + 2 elbows = 12m tubing)
Mounting the airbox:
9.4. Clearance around the stove to be respected
Fire safety measures concerning inflammable or temperature-sensitive floor
coverings:
The surface under the stove must have a fire-resistant, non-inflammable
covering (e.g. cast iron plate, marble or tile)
English
1. Remove the protection plate at the back
of the stove by means of two screws.
2. Remove the split-pin.
3. Loosen the screws on the air regulation
handle and dismount it
4. Unscrew the air regulation axle.
5. Move the airsliders to the outer left
position (maximum supply of combustion
air)
6. Mount the airbox with the joints.
7. Remount the axle of the air regulator
through the hole in the airbox
8. Put the shortest end of the regulation axle in
the air regulation handle and fix it with the
split-pin.
9. Remount the air regulation handle on the
back of the stove.
10. Move the airsliders left and right to check..
11.
Remount the protectionplate onto the
backside of the stove.