  • Page 1

    Contents 1. G eneral information .............................................................................................................45 2. T echnical characteristics ...................................................................................................45 3. D imensions of the s...

  • Page 2

    12. K indling ............................................................................................................................... ....54 13. S toking up of the fire with wood – f irewood ....................................................................55 14. S toking up of the fire wi...

  • Page 3

    Height mm 700 width mm 662 width with fully open right external wall mm 990 depth mm 510 height up to lower edge of connector pipe mm 485 outside diameter of the connector pipe Ø mm 150 connector pipe for combustion air Ø mm 100 height up to lower edge of ventilation pipe mm 225 small filler door op...

  • Page 4: Harmful

    Minimal pressure pa 12 minimal pressure at 0,8 times the nominal thermal capacity pa 8 46 3. Dimensions of the stove 4. Fuel the saey scope wood-burning stove is intended exclusively for burning and heating with wood, and is equipped with a grate. Wood: all types of dry firewood. Dry wood means soli...

  • Page 5

    The chimney comply with the locally applicable regulations (for germany: din 18160); the dimensions must be calculated if necessary. Before the stove is built in , the qualified chimney sweep must be asked whether the chimney and the combustion air supply are suitable. 6. Combustion air the saey sco...

  • Page 6

    From the side walls of the stove: at least 60 cm from the rear: at least 30 cm within the radiation range of the glass: at least 80 cm floor protection in front of the appliance: at least 50 cm floor protection at the sides: at least 30 cm 49 8. Connection of the stove to the chimney the stove can b...

  • Page 7

    When the heating appliance is used for the very first time, it must first dry out completely. For this purpose, heat it for one hour with a small quantity of fuel. Set the air inlet to “ i “. During this phase, a slight odour may be given off due to the curing of the primer used. Keep an eye on the ...

  • Page 8

    The control handle is inserted horizontally in the centre of the door, in the groove between the left side wall and the door in the sealer plate, and is pushed up against the lining. Now pull the control handle upwards, and the door will open. If desired, the left side wall can be opened slightly in...

  • Page 9

    A primary air inlet is situated on the rear of the appliance to facilitate regulation of the air supply and the post-combustion air via the openings above the glass. These can be regulated by means of the knob of the air slider on the right, behind the cover plate. Another marking is visible on the ...

  • Page 10

    Control handle, as indicated in the illustration. In position “0” the cast-iron knob is fully recessed in the sidewall, and in position “l” it is fully extended (see: division on inner surface of the side wall). Removing the ash pan before cleaning depending on the quantity of ash, the ash pan must ...

  • Page 11

    Once per heating season (preferably at the end of the season), the inspection cover must be removed from the appliance in order to remove the ash powder from the backflow preventor. The inspection cover must also be removed if you decide to use the top outlet instead of the one on the rear of the ap...

  • Page 12

    If necessary, an additional connector pipe for the combustion air (special attachment) can be attached to the rear of the wood-burning stove, so that the combustion air will not be supplied centrally. To do this, the radiation plate must first be loosened from its 4 anchor points. In addition, the c...

  • Page 13

    Substances is kept to a minimum, you must follow the following heating method after kindling the fire: place 3-4 small pieces of wood, max. 2,5 kg in size, in the appliance in two l ayers; set the primary air inlet to position “l”. The combustion air inlet in the sidewall must also be open. Top up f...

  • Page 14

    19. Faults malfunctioning cause solution wood too moist check; max. Residual moisture 20% wrong fuel use only the fuel allowed for the appliance chimney draught too weak: (minimal pressure: 10pa at the heating gas connector pipe) check the air-tightness of the outlet light a kindling fire in the chi...