SAF Lumina Series Configuration Manual

Manual is about: Full Outdoor Unit

Summary of Lumina Series

  • Page 1

    Cfip lumina series full outdoor unit technical description & configuration guide product code: i0dgetd1  saf tehnika jsc 2013.

  • Page 2: Table Of Contents

    Table of contents 1 overview .......................................................................................................................................... 5 1.1 cfip full outdoor units..........................................................................................................

  • Page 3

    4.2.4 upgrade software ................................................................................................................................... 55 4.2.5. Service information ......................................................................................................................

  • Page 4

    9.2.1 discovery of ip address and firmware version in case the subnet of cfip unit is unknown .............. 111 9.2.2 discovery of ip address and firmware version in case the subnet of cfip unit is known .................. 112 9.2.3 discovery of ip address and firmware version of remote cfip unit c...

  • Page 5

    Proprietary notice the information presented in this guide is the property of saf tehnika, jsc. No part of this document may be reproduced or transmitted without proper permission from saf tehnika, jsc. The specifications or information contained in this document are subject to change without notice...

  • Page 6

    • frequency bands: 6 / 7 / 8 / 10 / 11 / 13 / 15 / 17 / 18 / 23 / 24 / 26 / 38 ghz • green radio – 25-40w (standard power) and 29-52w (high power) power consumption per radio • acm and atpc with qos four priority queues • 802.1q vlan support 1.2.2 mechanical features • compact unit, 285x285x80mm (11...

  • Page 7

    Figure 1.2: optical cfip lumina fodu connectors figure 1.3: electrical cfip lumina fodu connectors figure 1.4: hybrid cfip lumina fodu connectors rssi port twin bnc odc port (lan1) odc port (lan2) dc connector rj-45 port (lan4) rj-45 port (lan3) rj-45 port (lan3) odc port (lan2) the cfip lumina seri...

  • Page 8

    1.3 radio parameters • cfip lumina is a good example of latest achievements in modem and transceiver development, providing both excellent radio parameters (system gain), due to use of qam modulations and efficient despite it consumes small amount of power tx/rx part of the system. • rsl threshold a...

  • Page 9

    Figure 1.6 cfip lumina 2+0 link aggregation 1.4.3 cfip lumina east/west chain figure 1.7 cfip lumina east/west chain 1.4.4 cfip lumina ring topology • utilization of stp protocol allows cfip lumina operation in ring topology the cfip lumina series full outdoor unit technical description and configur...

  • Page 10

    Figure 1.8 cfip lumina operation in ring topology 1.5 technical specifications iii cfip lumina fodu technical specification frequency range (ghz) 6 7/8 10/11 13/15 17 18/23 24 26 38 channel bandwidths (mhz) 1 14 - 56 modulation 4qam / 16qam / 32qam / 64qam / 128qam / 256qam capacity (mbps) 24 – 366 ...

  • Page 11

    Iii ethernet switch type managed gigabit ethernet layer 2 max frame size 9728 bytes mac table 4k entries; automatic learning and aging packet buffer 128kb; non-blocking store&forward flow control 802.3x vlan support 802.1q (up to 4k vlan entries) qinq (double tagging) yes qos 64 level diffserv (dscp...

  • Page 12

    Iii cfip lumina rx sensitivity, payload capacity bw 1 , mhz modulation fec 2 6 ghz 7 ghz 8 ghz 10 ghz 11 ghz 13 ghz 15 ghz 17 4 /18 ghz 23 ghz 24 ghz 26 ghz 38 ghz capacities, mbps 20 4qam strong -92 -91 -90.5 -90 -91 -91 -90.5 -91.5 -90.5 -90.5 -92.5 -86.5 24 16qam strong -84.5 -84.5 -84.5 -84 -85 ...

  • Page 13

    Iii cfip lumina rx sensitivity, payload capacity bw 1 , mhz modulation fec 2 6 ghz 7 ghz 8 ghz 10 ghz 11 ghz 13 ghz 15 ghz 17 4 /18 ghz 23 ghz 24 ghz 26 ghz 38 ghz capacities, mbps 28 4qam strong -90.5 -89.5 -89 -88.5 -89.5 -89.5 -89 -90 -89 -89 -91.5 -85 35 16qam strong -84.5 -83 -83 -82.5 -83.5 -8...

  • Page 14

    Iii cfip lumina tx power modulation standard/high tx power, dbm 6, 7, 8 ghz 10, 11, 13, 15 ghz 17 ghz 4,5 18, 23, 26 ghz 24 ghz 4,5,6 38 ghz 4qam +19 / +27 +19 / +25 -25…+5 +19 -20…0 +17 16qam +18 / +26 +18 / +24 -25…+4 +18 -20…-1 +16 32qam +17 / +25 +17 / +23 -25…+3 +17 -20…-2 +15 64qam +15 / +23 +...

  • Page 15

    (!) power connector can be soldered in any polarity layout. Optional accessory power adapter cable with screw terminal (p/n i0acge04/i0acge05 (0.3/1.0m)) does not require soldering and can accept power cable up to awg14 with maximum cable length up to 745m / 2444ft (35w): awg lmax @ 50w lmax @ 35w l...

  • Page 16

    Cfip lumina high power 1.8 sfp (small form-factor pluggable transceiver) initial version of cfip lumina is equipped with internal 1310 nm single-mode transceiver, (1000base- lx) sfp module (p/n i0aom001) with following features: - compliant with ieee 802.3z gigabit ethernet standard; - compliant wit...

  • Page 17

    Part number product name wavelength media distance application tx power rsl threshold temp i0amom01 sfp 850nm mm transceiver 1000base- sx 3.3v 850 nm mmf 550 m / 1800 ft. 1000base-sx -9.5..-4 dbm -20..+85c - 4..185f i0aom001 sfp 1310nm sm transceiver1000base- lx 3.3v 1310 nm smf 10 km / 6.21 miles 1...

  • Page 18

    Figure 1.14. Electrical cfip lumina site figure 1.15. Electrical cfip lumina site 1.11 labelling the label can be found on the front side of the unit. The label contains the following information (see samples in the picture below): the cfip lumina series full outdoor unit technical description and c...

  • Page 19

    - model name (“cfip-18-lumina”). The fodu model name example is: - cfip-18-lumina for 18ghz fodu, - cfip-23-lumina for 23ghz fodu, etc - product number (i18gut05lb): product number contains information in which band side (l, h) the fodu operates. Letters a, b, c or d indicate specific subband. - uni...

  • Page 20

    K – capacity limitation up to 184mbps “03” designates the version number of the unit; “l” designates the band side in which fodu operates (h, l); please note that frequency range is set from the central frequency of the first 20 mhz channel to the central frequency of the last 20 mhz channel (see th...

  • Page 21

    2 installation and configuration there are four ways to adjust and read settings and operation parameters of the cfip lumina equipment: 1. Using web terminal (ethernet interface), 2. Using telnet terminal (ethernet interface), 3. Using nms or snmp terminal (ethernet interface), or 4. Using ascii con...

  • Page 22

    7 figure 2.1. Assembling weatherproof dc power connector 1. You will need: (1-6) dc connector components and (7) ready 2-wire dc power cable. 2. Wider sealing rubber ring should be fitted inside from the front end of (6). 3. Narrower sealing rubber ring should be fitted inside from the rear end of (...

  • Page 23

    Figure 2.3. Interconnection of power over ethernet injector, splitter and cfip lumina 2.3 attaching cfip lumina fodu to antenna you need only tightening one tool to attach cfip lumina to the antenna. Use two guidance pins for fixing polarization and 4 side lockings for attachment. Lockings should be...

  • Page 24

    (!) in case of 6ghz (n-type connectors) polarization is determined by antenna and should be same on both ends of the link. Examples: 7ghz (vertical polarization) 23ghz (horizontal polarization) (!) lockings should be positioned in way it is shown on picture. Unlicensed frequency bands 17/24 ghz pair...

  • Page 25

    2.4 resetting the cfip lumina depending on the method used, the user may reset the whole terminal or the management controller individually, see table below for details. Reset action unplugging power source. Restarts both the multiplexer module and the management module. Resets all management counte...

  • Page 26

    Figure 2.4. 2) find ‘local area connection’, click right mouse button on it and choose ‘properties’ figure 2.5. 3) click on ‘internet protocol (tcp/ip)’ from the list in the dialog box and then click on ‘properties’ figure 2.6. 4) in the dialog box enter the following values (so that your pc is in t...

  • Page 27

    Figure 2.7. Now you are ready to connect to web gui or establish telnet connection. 2.5.3 connecting to web interface it is recommended to use the following web-browsers (and all later versions): • ie v. 6.0 • mozilla firefox v. 2.0.0.11 • safari v. 3.0 • opera v. 9.50 • google chrome after web brow...

  • Page 28

    If the ip address is correct and you have suitable browser version, you will see confirmation text. After confirmation you will be redirected to web interface page. In case of not valid ip address you will not obtain the configuration interface. In case your browser is not accepted, you will see the...

  • Page 29

    2.5.4 interface description web interface consists of four parts, they are: 1. Top panel, that allows to log out and gives information about device type, software version, device name, ip, serial number and uptime; 2. Menu panel that is used to open links to other pages; 3. Status summary for local ...

  • Page 30

    2. Sub-header of single type configuration parameters; 3. Configuration parameter name; 4. Configuration parameter current value; 5. Execution controls related to a single type configuration parameters. 6. Write to config file button, which generates “cfg write” cli command, which saves changed conf...

  • Page 31

    Go to control panel network connections local area connection properties internet protocol (tcp/ip) properties): – ip address 192.168.205.1; – netmask 255.255.255.0; – everything else is blank. Figure 2.12. The next step is to connect to cfip lumina by entering ip in the browser address line – which...

  • Page 32

    To start simple configuration process, you must proceed with the configuration wizard which will set up the main parameters of the link to make it work. So, the first step is to go to ‘configuration configuration wizard’as shown below in the figure 2.14. Figure 2.14. Starting configuration wizard. I...

  • Page 33

    Figure 2.15. Step 1. Defining system name and passwords for “guest” and “admin” accounts. After accepting and pressing ‘next step >>’ button, you will be redirected to the second configuration wizard screen, where you will be asked to define the network ip settings by entering ip address, ip mask an...

  • Page 34

    The final screen allows checking the selected settings and applying them. The optional settings are as follows: – clear cfg file before the new settings will take place – resetting or keeping all the other parameters, not mentioned here, after configuration execution – set local machine time – uses ...

  • Page 35

    2.6.1 rs-232 serial management port rs-232 serial management port provides terminal management via connected pc or another terminal device or modem. The terminal connected to serial management port provides the same management functionality as telnet interfaces (refer to chapter 2.3.2). In order to ...

  • Page 36

    4. Choose port (com1 or com2). Figure 2.21. 5. Set port settings (bits per second: 19200, data bits: 8, parity: none, stop bits: 1, data flow control: none). Figure 2.22. 6. Press ok the cfip lumina series full outdoor unit technical description and configuration guide • rev. 1.10 • © saf tehnika js...

  • Page 37

    7. Press enter. Password is disabled by default. If successfully connected, the prompt should appear as in the picture below. See chapters 3-7 for available commands. Figure 2.23. 2.6.2 telnet connection telnet connection to cfip lumina is carried out using ethernet management connection. Please ref...

  • Page 38

    3) if the ethernet management connection is configured properly, you will see a window similar to the one shown below, where you will be asked to enter login and password. Default login is identical to web login name – user name is admin and password – changeme. Figure 2.24. After you have correctly...

  • Page 39

    – tx power with the command ‘radio txpower []’; – tx frequency with the command ‘radio freq []’; – channel bandwidth and modulation with the command ‘modem set ’, where you can choose among 14, 20, 28, 30, 40, 50 or 56 mhz values; – name of cfip lumina with the command ‘system name ’. Default name i...

  • Page 40

    3 status in web gui status menu and submenu items in web gui summarize current system status and configurations, alarm status, ethernet 2+0/1+1 aggregation/protection status, inventory information and provide ability to download troubleshooting data. Following information is available both for admin...

  • Page 41

    5. Shows short summary of the main operational parameters of local and remote system. • rx level (or rsl) at both ends must not differ significantly from the previously calculated value. • modulation indicates which modulation mode is used. For better operation the same modulation must be set at bot...

  • Page 42

    25. Acm engine – shows if acm (adaptive coding and modulation) engine is running (command line – modem status or status); 26. Current modulation rx / tx – shows the modulation modes currently utilized (command line – modem status); 27. Current link capacity rx / tx – shows the current capacities in ...

  • Page 43

    Figure 3.2 ldpc decoder structure ldpc stress value thresholds @ ber 1.0⋅10 -6 : - for strong fec mode ~ 4.0⋅10 -2 ; - for weak fec mode ~ 1.0⋅10 -3 as long as ldpc stress value is under the specified thresholds, the amount of errors (and ber itself) on the output of ldpc remains at zero level. 3.2 ...

  • Page 44

    4. Max n/d time: - displays maximum disconnection time between devices; 5. Alarms - displays alarm notifications: − local modem airloss – there is no radio connection between local and remote device − lan1-4 link down – media is disconnected; − no data from device nr.1-4 – media is connected but not...

  • Page 45

    4 configuration in web gui configuration section in web interface allows customizing your system to suit your specific needs. 4.1 main configuration the main configuration window provides the configuration of most vital system parameters, including the ones in configuration wizard as well as some ot...

  • Page 46

    8. Pressing „execute configuration” applies changes made to the corresponding section only for the local side cfip lumina. If „rollback on” is selected, configuration will be reverted in case of erroneous configuration changes applied. 9. Pressing „execute for both” applies changes made to the corre...

  • Page 47

    Atpc algorithm acm can be implemented together with automatic transmit power control (atpc), complimentary features that enhance overall system performance. Atpc reduces the average transmitted power as well as cci and adjacent-channel interference (aci), which is caused by extraneous power from a s...

  • Page 48

    1. Modem data status – shows if management cpu was able to read data from modem; 2. Bandwidth – allows choosing between 14, 20, 28, 30, 40, 50 and 56 mhz etsi and ansi (fcc) bandwidths available. The default value is 14 mhz (for p/n i**g******/i**s******) or 20mhz (for p/n i**n******/i**h******). Ba...

  • Page 49

    Full modulation range: 256qam, 128qam, 64qam, 32qam, 16qam, 4qam traffic can be mapped into different priorities, which define the level of service for each application. Figure 4.3 illustrates how different services – such as rich voice and video – are mapped into different classes of availability (...

  • Page 50

    Figure 4.3. Link availability and classes of services in comparison similar system using 256qam and providing similar capacity would provide only 99,687% of availability. Besides, lack of acm would not provide higher availability. You would have to decrease the distance, decrease modulation or incre...

  • Page 52

    Figure 4.5. Cfip lumina radio frequency loopback graph for example, if radio frequency loopback indicated rx level = -55dbm, cfip lumina can operate with tx power up to 0dbm. Additional radio and modem configuration commands in telnet/serial interface command description modem status shows the statu...

  • Page 53

    4.2 system configuration the system configuration window provides the configuration of web access, telnet and ftp interfaces; allows changing system name, web data refresh time and system time. Explanation of customization fields: 4.2.1 user configuration 1. Guest – enter new password (length: 4..30...

  • Page 54

    4.2.2 names configuration 1. System name (max length: 16 characters) – allows entering preferable system name. Maximum length of the system name cannot exceed 16 symbols. Default name is ‘saf’ (command line – system name ); 2. Location name (max length: 16 characters) – allows entering preferable sy...

  • Page 55

    4.2.4 upgrade software 1. Choose file – allows choosing location of software upgrade file (e.G. Cfipl153.Elf.Ezip) stored on your hard disk. Software upgrade file must have *.Elf.Ezip extension. 4.2.5. Service information 1. Open full system information page / download system information – allows to...

  • Page 56

    4.3 ip configuration window the ip configuration window provides configuration of the ethernet management port addressing, ip services and routes. Settings listed here are essential for building a network or other specific traffic purposes. Explanation of customization fields: 4.3.1 ethernet managem...

  • Page 57

    4.3.3 static route configuration 1. Static routes – shows the list of existing static routes, as well as allows you to choose specific route you are willing to change or delete. By default there is one route which depends on earlier entered ip settings (command line – net route); 2. Network address ...

  • Page 58

    Below is the explanation of the procedure of network ip configuration in case of network ip class area change. For the purpose of illustration, we use b class ip network address 10.0.10.11 for the remote side cfip and 10.0.10.10 for the local side cfip, while the ip address of our management pc lan ...

  • Page 59

    4) go to the remote side web gui, choose “tools  configuration file” and press “cfg write”. 5) repeat step 4) for the local side web gui. 4.4 ethernet configuration the ethernet configuration window provides the speed settings for all four lan ports of ethernet switch as well as shows the current s...

  • Page 60

    9. Tx state – shows if egress activity is allowed; 10. Speed (set) – shows current operation mode of each port and allows to set manual speed setting (10hdx/10fdx/100hdx/100fdx/1000fdx) (command line – ethernet set connection >); 11. Ethernet flowcontrol – allows manually disabling or enabling flow ...

  • Page 61

    1. Do not interconnect cfip lumina with each other and do not plug cfip lumina into switches before you have finished the configuration. 2. Choose one link which will operate as “master”. Other link will operate as “slave” 3. Configure each link separately in mode you would like to operate. All cfip...

  • Page 62

    1. Role – choose “master”; 2. Mode – choose “aggregation” for link aggregation 2+0 or “protection” for link protection 1+1; 3. Revertive mode – in case of “enabled” setting link will automatically reconfigure back to 2+0 operation when unit/cable/link failure is resolved. In case of “disabled” setti...

  • Page 63

    A ip address of master unit (directly connected to slave unit b) b ip address of slave unit (you are configuring) c link id for master link (same link id should be set on second master unit) d link id for slave link (same link id should be set on second slave unit) e lan port number which will be us...

  • Page 65

    To ensure correct operation of vlans, both individual vlan ids and general 802.1q vlan should be enabled. 4.6.1 ethernet switch port status and settings figure 4.6. Switch lan ports 1, 2, 3 and/or 4 (depends on cfip lumina model) are connected to lan interface. Switch wan port is connected to wan in...

  • Page 66

    Ext. Switch 1 int. Switch 1 cpu 1 int. Switch 2 cpu 2 cfip1 cfip2 user dat a mm dat a port 1 port 2 port 3 mng(6) lan 1,2,3 ,4 wan(5) wan(5) lan 1,2,3 ,4 mng(6) ext. Switch 2 user dat a mm dat a port 1 port 2 port 3 figure 4.8. System with vlans system with two separate vlans – a and b. Figure 4.9. ...

  • Page 67

    Ext. Switch 1 int. Switch 1 cpu 1 int. Switch 2 cpu 2 cfip1 cfip2 user dat a user dat a port 1 port 2 port 3 mng(6) wan(5) wan(5) mng(6) ext. Switch 2 user dat a user dat a port 1 port 2 port 3 vlan a vlan b&c vlan a vlan b vlan c vlan c vlan b vlan b&c vlan a management data management data vlan a ...

  • Page 68

    Figure 4.11. Vlan configuration on one cfip lumina lan port on right side of the link and on two cfip lumina lan ports on left side of the link 4.7 qos 4.7.1 general configuration qos status provides control over main qos parameters, accordingly allowing enabling or disabling qos 802.1p, diffserv or...

  • Page 70

    If any queues are empty, the highest non-empty queue gets one more weighting. For example, if q2 is empty, q3:q2:q1:q0 becomes (8+1):0:2:1. In case of fixed queuing mode, highest priority buffer (q3) will pass packets as long as its buffer is full. By default weighted priority queuing mode is enable...

  • Page 71

    1. Dscp mapping – allows assigning queues for different dscp classes. You may have up to 64 different traffic dscp classes; 2. Pressing „execute configuration” applies changes made to the corresponding section only for the local side cfip lumina. If „rollback on” is selected, configuration will be r...

  • Page 72

    4.8.1 spanning tree configuration bridge configuration - values 2-4 take effect only if a given bridge is root: 1. Bridge id – value from (0..61440); this parameter and mac address determine whether a given bridge is root bridge. Advantage is given to the combination of priority and address, which i...

  • Page 73

    18. P5 (wan) – stp parameters of wan port: - priority (0..240) – port priority. Combination of priority, port number and path cost determines whether the port will be selected as root port or will be blocked on the occasion of loop, etc; - path cost (1..200000000) – this parameter setting depends on...

  • Page 74

    4. By pressing „execute configuration” changes made to the corresponding section apply only for the local side; 5. Vlan (1 – 4094) – map vlan id or vlan ids range for each instance. Up to seven instances; 6. Write to config file - saves to configuration file all the changes made on the whole page (c...

  • Page 75

    4.9 snmp v1/v2 configuration the snmp v1/v2 configuration pages provide configuration of snmp communities, host and trap addresses. Saf nms system will work only when snmp is properly configured. Explanation of customization fields: 4.9.1 snmp community configuration 1. Read - specifies snmp v1/v2 c...

  • Page 76

    Connected to the cfip lumina is not added to the cfip snmp v1/v2 host table, cfip lumina will not respond to the snmp requests from that host. If „rollback on” is selected, configuration will be reverted in case of erroneous configuration changes applied. 2. Allows to add or delete snmp host ip addr...

  • Page 77

    5 performance and alarm management 5.1 alarm management 5.1.1 alarms and events structure all alarms and events are placed in indexed table. Low level raw alarms and events are placed in the first table. Raw alarms and events are merged in groups, which are placed in the second indexed group table. ...

  • Page 78

    12 12 system temperature fault temperature is out of defined range 13 13 no data from main psu adc no data from the main psu adc 14 14 main supply voltage failure main supply voltage is out of defined range 15 15 main supply current failure main supply current is out of defined range 16 16 main supp...

  • Page 79

    45 36 command from interface message about command execution from particular interface 46 37 message of event informative message 47 38 eth interface ethernet lan port state change 48 39 aggregation state was changed event of aggregation state change in aggregation 2+0 or protection 1+1 configuratio...

  • Page 80

    Figure 5.3. Alarm log window 5.1.5 alarm and alarm threshold configuration the alarm configuration screen allows you to configure alarm representation. You have a choice to see specific alarm groups globally in alarm status (global), in alarm log (log) or in nms system (snmp). By default all alarms ...

  • Page 81

    Figure 5.4. Alarm configuration window alarm threshold configuration screen allows you to define specific threshold levels to bound alarms to desirable values, so that you are able to adapt alarm system to your individual needs. Alarms in bold font represent group alarms and alarms in normal font – ...

  • Page 82

    Figure 5.5. Alarm threshold configuration window 5.1.6 alarm management commands to manage alarms in command prompt, the commands are as follows: alarm management commands command description log show [] the management controller maintains event log, - events include configuration changes, managemen...

  • Page 83

    5.2 performance management the main aim of the performance management is to register mostly critical device performance event values in predefined time intervals. 5.2.1 performance management data collection the performance parameters are collected within time intervals of 1 min., 15 min. And 1 hour...

  • Page 84

    Figure 5.6. Functional architecture for data collection, history and thresholding treatment 5.2.2 performance values threshold seconds (ts) the ts is defined as one second period during which the detected value is outside of predefined thresholds. The current value of the counter associated with ts ...

  • Page 85

    Figure 5.7 selecting performance log parameters figure 5.8 performance log window time interval can be chosen between 1 min, 15 min or 1 hr. You can also define the start time and the start date. When start values are defined, it is also possible to define the end time and the end date. Ts (threshol...

  • Page 86

    Figure 5.9 performance log configuration window the main advantage in terms of demonstration means is obtained from ‘performance graphs’, which are found in ‘performance  performance graph’ section. You are able to choose between 8 parameters – rx level, tx level, radial mse, ldpc stress, modem tem...

  • Page 87

    1. Time scale selector. User can select the scale and accuracy (1 / 15 / 60 minutes). The lower the accuracy, the longer period will be available for data (mechanism of the performance management system) 2. Updates the performance graph; the latest data is shown 3. Shows / hides period settings (poi...

  • Page 88

    Figure 5.12. Non-coherent single frequency interference (4qam) 3) phase noise is displayed as rotationally spreading constellation points: figure 5.13. Phase noise (4qam) 4) amplitude compression causes the corner points to move towards the centre: figure 5.14. Amplitude compression (64qam) examples...

  • Page 89

    Figure 5.15. Constellation diagram – 4qam, 16qam, 32qam, 64qam, 128qam, 256qam 5.2.5 adaptive equalizer cfip lumina features adaptive equalizer, which is a filter that automatically adapts to time- varying properties of a communication channel with selective fading, having a target to compensate the...

  • Page 90

    During normal operation frequency response curve is smooth and the only equalizer tap towers are in the centre of equalizer taps graph, otherwise frequency response curve will appear jagged and many equalizer taps will become visible. The latter case most probably will indicate to multipath issue, w...

  • Page 92

    5.3 ethernet modem statistics ethernet modem statistics window shows the full ethernet and framing statistics of cfip modem since unit start or statistics reset. All statistics are also accessible using command prompt command ethernet statistics all. Explanation of fields: 1. Shows time period durin...

  • Page 93

    17. Code errors – one or more nibbles are signalled as errors during reception of the packet; 18. False carrier errors – indicates that following the last received statistics vector, a false carrier was detected, noted and reported with next received statistics. The false carrier is not associated w...

  • Page 94

    5.4 ethernet switch statistics ethernet switch statistics window shows the full ethernet statistics of cfip switch since unit start or statistics reset. All statistics are also accessible using command prompt command ethernet counters . Explanation of fields: 1. Shows the time during which statistic...

  • Page 95

    6. Txbroadcastpkts - the number of good packets transmitted by a port that are directed to a broadcast address. This counter does not include errored broadcast packets or valid multicast packets; 7. Txmulticastpkts - the number of good packets transmitted by a port that are directed to a multicast a...

  • Page 96

    Counter and the rxexcesssizedisc counter are incremented for packets of 1537 bytes and higher; 30. Rxjabbers – the number of packets received by a port that are longer than 1522 bytes and have either an fcs error or an alignment error; 31. Rxalignmenterrors - the number of packets received by a port...

  • Page 97

    6 miscellaneous controls in web graphic user interface these controls are located in the navigation panel under the “tools” item. 6.1 ethernet/configuration files this section allows working with cfip system and ethernet configuration script. The management module has ram and eeprom chips onboard. W...

  • Page 98

    1. Download cfg file – allows downloading system configuration file and saving it on your hard drive. The cfip lumina series full outdoor unit technical description and configuration guide • rev. 1.10 • © saf tehnika jsc 2013.

  • Page 99

    2. Upload configuration file - allows uploading system configuration file to cfip lumina flash memory. In order to load configuration file from system memory, cfg restore should be used (refer to number 9); 3. Saved configuration file - shows contents of system configuration file saved in eeprom mem...

  • Page 100

    16. Saved configuration file - shows contents of system configuration file saved in eeprom memory. Commands contained in this configuration file are executed at every system start-up; 17. Running configuration file - shows currently running system configuration file (command line – eth config). In o...

  • Page 101

    1. License status – shows if management cpu was able to read license data (command line – license status); 2. Version – shows what the license version of selected license key is. 1 – license without ethernet rate limiting, 2 – license with ethernet rate limiting (command line – license status); 3. L...

  • Page 102

    16. System returned – in case of error or incorrectly entered parameter value, or other problems on the whole page – info message will be displayed here.. Otherwise it says “ok”. 6.3 command line in the command line you are able to execute all the commands to manage the cfip lumina which are availab...

  • Page 103

    7 file system the software used by the cfip management controller is organized in files, which are stored on flash disk. Firmware and boot configuration files the following files are required for the cfip to start: – ‘boot.Ini’ file, - device boot configuration file. This file is a text file and con...

  • Page 104

    Management controller. Tfs edit edits the specified file. This command is applied for editing configuration backup files and boot configuration file (boot.Ini). For example, edit boot.Ini,be – file ‘boot.Ini’ will be opened for editing. ‘be’ specifies that this file will be saved with attributes ‘b’...

  • Page 105

    8 software update to simplify the firmware update process, saf tehnika jsc provides special update package, as a new version is available. This update pack is available as archive (e.G. Zip), which includes firmware file (with *.Elf.Ezip,ec extension), upgrade instructions, release notes and mib fil...

  • Page 106

    – ttftp.Exe 192.168.205.10 put cfipl000.Elf.Ezip,ec uploads firmware file named ‘cfipl000.Elf.Ezip’ with attribute flags ‘e’ and ‘c’ to host cfip with ip address 192.168.205.10. – start tftp on both link sides in ‘configuration  ip configuration’: – run ‘send.205.Xx.Cmd’ to perform update, where „x...

  • Page 107

    Where: ‘-i’ – key which specifies that file must be transferred in binary image transfer mode; ‘192.168.205.11’ – cfip ethernet management port ip address (host); ‘c:\files\cfipl000.Elf.Ezip’ – firmware file (source); ‘cfipl001.Elf.Ezip’ –file name in the cfip flash memory (destination); ‘ec’ – file...

  • Page 108

    2. Start ftp client by entering “ftp” command (“ftp>” prompt will appear). 3. Connect to cfip ftp server using command “open ”. Type in username and password when prompted (by default username is admin and password is changeme). 4. Enter the command “type binary” to make sure the binary transfer mod...

  • Page 109

    When upload is complete, the following information will be displayed (figure 7.2.): figure 7.2. 5. Enter ‘reset’ command to exit from micromonitor mode and restart the cfip. 6. Proceed with steps 5. And 6. In chapter 7.1. The cfip lumina series full outdoor unit technical description and configurati...

  • Page 110

    9 cfip discovery protocol discovery protocol is layer 3 network protocol. This feature allows gathering information from connected cfip devices. The protocol discovers the ip address and software version of connected cfip unit. Discovery protocol uses udp packets sent on port 78. Discovery protocol ...

  • Page 111

    9.2 discovery protocol performance examples 9.2.1 discovery of ip address and firmware version in case the subnet of cfip unit is unknown for this purpose the command “dp sight ” should be executed in ‘cmd’. Instead of place the ip address of your pc ethernet adapter that is connected to cfip unit. ...

  • Page 112

    9.2.2 discovery of ip address and firmware version in case the subnet of cfip unit is known for this purpose the command “dp scan ” should be executed in ‘cmd’. Instead of place the ip address of your pc ethernet adapter that is connected to cfip unit and instead of place the broadcast address of sp...

  • Page 113

    9.2.3 discovery of ip address and firmware version of remote cfip unit connected to router in case one ip address of remote units is known for this purpose the command “dp remote ” should be executed in ‘cmd’. Instead of place the ip address of your pc ethernet adapter that is connected to router/cf...

  • Page 114

    10 rssi port rssi (received signal strength indicator) port is used to adjust the alignment of antenna for best performance (for both rough and fine adjustment); this can be done using digital multimeter which is connected to the rssi port. The output of the rssi port is dc voltage and varies depend...

  • Page 115

    11 pinouts 11.1 odc connector optical interface of cfip lumina is available using odc connector. Pinout is shown in figure 9.1. Figure 9.1. Cfip lumina odc connector pinout 11.2 rj-45 connector the pinouts of that socket are as follows: figure 9.2. Cfip lumina rj-45 connector pinout 11.3 twin bnc co...

  • Page 116

    11.4 dc power connector dc power connector can be connected in any preferable layout: figure 9.4. Dc power connector pinout 1 +/– 2 –/+ 1 2 the cfip lumina series full outdoor unit technical description and configuration guide • rev. 1.10 • © saf tehnika jsc 2013.

  • Page 117

    12 available accessories fodu rj-45 connector 8p shield solid p/n foacnr02 sfp 850nm mm transceiver 1000base-sx 3.3v p/n: i0amom01 sfp 1310nm sm transceiver 1000base-lx 3.3v p/n: i0aom001 test equipment for further details see chapter 11.2 o-ring - rubber gasket to be fitted between 0.25m antenna an...

  • Page 118

    Hermetic connector for power cable p/n: i0acnp01 cfip lumina lc-odc cable 3m sm p/n: i0aco001 3m mm p/n: i0acm001 10m sm p/n: i0aco002 10m mm p/n: i0acm002 50m sm p/n: i0aco003 50m mm p/n: i0acm003 coaxial attenuator 40 db p/n cla40a01 saf adapted omt for arkivator 0.3/0.6/0.99/1.2m antenna for dual...

  • Page 119

    Fodu cable twin bnc - db9 (2m). P/n foactw01 12.1 ac/dc power adapters power (w) injector (p/n) power adapter (p/n) connector supplied standard 60 - i0ab4806 terminal block etsi, eu plug 60 - i0ab4805 terminal block fcc, usa plug 60 - i0ab4817 terminal block aus plug 60 i0atpi07 i0ab4812 - etsi, eu ...

  • Page 120

    Ubr-pbr waveguides omt omt (arkivator) 7ghz p/n: c07om31001i 7ghz omt (orthomode transducer) saf adapted for direct mount to arkivator 0.3, 0.6, 0.99 and 1.2m antennas omt (arkivator) 11ghz p/n: c11om31001i 11ghz omt (orthomode transducer) saf adapted for direct mount to arkivator 0.3, 0.6, 0.99 and...

  • Page 121

    13 list of abbreviations ac – alternating current aci – adjacent-channel interference acm – adaptive coding and modulation ascii - american standard code for information interchange atpc – automatic transmit power control ber – bit-error ratio bnc connector - bayonet neill-concelman coaxial connecto...

  • Page 122

    Snmp - simple network management protocol snr – signal-to-noise ratio stp – spanning tree protocol tcp/ip – internet protocol suite (transmission control protocol / internet protocol) tdm – time-division multiplexing tftp – trivial file transfer protocol tm – tide mark tp – twisted pair ts – thresho...

  • Page 123

    14 saf tehnika jsc contacts saf tehnika a/s technical support can be reached by: - email: techsupport@saftehnika.Com - telephone: +371 67046840 - fax: +371 67046809 the cfip lumina series full outdoor unit technical description and configuration guide • rev. 1.10 • © saf tehnika jsc 2013.