Safety Technology International STI-34108 Installation And Operation Manual

Summary of STI-34108

  • Page 1

    — 1 — installation and operation manual sti 8-channel receiver thank you for purchasing this fine product. Your satisfaction is very important to us. Please read this manual carefully to get the most from your new product. How the product works sti offers multiple wireless products designed to alert...

  • Page 2: Installation Guide

    — 2 — installation guide surface installation: 1. Ensure mounting screws are removed. 2. Insert rubber feet (provided) into holes on bottom cover. 3. Route wires under the product. Wall mounted installation: 1. Ensure rubber feet are removed. 2. Remove front cover screw. 3. Remove cover (be careful ...

  • Page 3

    — 3 — component descriptions (top side): switches (1- 8) - for reference, information is also written on the receiver case (located under zone id list). 1 - mirror master off/on 2 - normal/enroll 3 - auto restore/latch 4 - siren time/mirror# 5 - siren time/mirror# 6 - chime off/on 7 - normal/delete ...

  • Page 4

    — 4 — normal operation the receiver receives 433 mhz radio signals from numerous sti sensors enrolled to the receiver. It provides feedback in the form of led colors, onboard sounder annunciation, onboard sounder siren, switched on or off output terminals (form c contacts), a 3 second 12 vdc @ 75ma ...

  • Page 5

    — 5 — enrolling sensors into zones: 1. Check that the module is not in delete mode (sw7 off). 2. If the zone should have “latching” set (sw3 on). 3. Enable enroll mode set (sw2 on). 4. Checkthatthezoneflashinggreeniscorrect,andnotethezone(s)withredleds. 5. Change the status of the sensor to be enrol...

  • Page 6

    — 6 — mirrored receiver operation: the leds, the sounder, the siren time and the 12vdc output activation will duplicate the sensor settings enrolled on the master receiver. If a sensor is enrolled to a mirrored receiver instead of the master, a transmission from the master receiver will override the...

  • Page 7

    — 7 — enrolling sensors into master + mirror receiver systems (with or without latching): when using a master + mirror receiver system, the latching feature is set independently on the master and/or mirror receivers. Latching on the master and/or mirrored receivers is only set for a zone at the time...

  • Page 8

    Safety technology international, inc. 2306 airport rd • waterford, mi 48327 phone: 248-673-9898 • fax: 248-673-1246 info@sti-usa.Com • www.Sti-usa.Com safety technology international (europe) ltd. Unit 49g pipers road • park farm industrial estate • redditch worcestershire • b98 0hu • england • tel:...