Safety Technology International STI-6400 Exit Stopper Instruction Manual - page 3
3
S
PECIFICATIONS
Polycarbonate Enclosure:
Dimensions
5.375” W x 5.375” H x 2 “ D (137mm x 137mm x 51mm)
Flammability:
UL94 V-2
Wall Thickness:
0.12 in (3.05mm)
Electronics: STI-6400 - All Units
9 VDC Alkaline or 9V-24VDC wired
Class II UL Listed transformer
Horn Volume at 1 ft.
95 dB low / 105 dB high
Relay Output
Form C Dry Contacts 0-30 VDC or VAC, 1 Amp
Stand by Current
10uA
Alarm Current
130mA at 95 dB / 200mA at 105 dB
Electronics: STI-6403 and STI-6404 - Remote Horn Unit
Power Source
9 VDC Operating Power* only
Horn Volume at 1 ft.
95 dB low / 105 dB high
Stand by Current
0 A
Alarm Current
50mA at 95 dB/ 200 mA at 105 dB
*Power source for the STI-6403 Remote Horn uses a separate power source from the STI-6400
alarm. The Remote Horn contains an internal 9 volt battery. Horn operates when the Form C
contact at main unit is activated on alarm.
Power Source