Safety Technology International STI-V34104 Manual

Summary of STI-V34104

  • Page 1

    - 1 - 4-channel voice receiver sti-v34104 how the product works the 4-channel voice receiver is a multipurpose long-range receiver that works with a wide range of sti wireless alert series sensors. Most products can achieve up to 1,000’ receiver range (line of site). Four zone indicators light up to...

  • Page 2

    - 2 - before you start review detailed product specifications (fig. 1 and 2) antenna jack · internal antenna with product · use external for maximum range volume control lamp controller output · works with sti lamp controller (sti-30104) · 3.5mm mono jack, center negative · 12vdc, 75ma 3 sec power s...

  • Page 3

    - 3 - zone programming procedures only receives wireless signals from the sti wireless alert series products. Program up to 4 sensors or keyfobs. Does not allow programming into an occupied zone. Cannot program the same sensor into more than one zone. The unit will state, “please change to normal mo...

  • Page 4

    - 4 - programming 1. Plug in receiver. 2. Listen to verbal voice commands. They will guide you through programming. Notes · firmly press acknowledge button at any time to stop voice. · make sure battery is installed in sensor. · each sensor provides an initial sound (dong). (see chart 2 below) · eac...

  • Page 5

    - 5 - advanced programming 1. Make sure switch is in program mode 2. Press zone/message selection button intended for sensor advanced programming 3. Move dip switches to correct position for selected word 4. Press zone/message selection button to accept word (repeat for up to four words/tones) cauti...

  • Page 6

    - 6 - 3 4 5 6 7 8 english spanish 0 0 0 1 0 0 4-note chime carillon de 4 notas 0 0 0 1 0 1 8-note chime carillon de 8 notas 0 1 1 0 1 0 alert alerta 0 1 1 1 0 1 assistance asistencia 1 1 0 0 0 1 barn granero 1 0 1 0 1 1 basement sotano 0 0 1 0 0 1 bell campana 1 1 0 1 1 1 button boton 0 0 1 0 1 0 bu...

  • Page 7

    - 7 - delete sensor 1. In program mode simultaneously press and hold the acknowledge button and zone/ message selection button for three seconds. 2. Successful when receiver states, “zone [number] is empty,” and green led is off. Low battery / tamper / out of range alert the 4-zone led light indicat...

  • Page 8

    - 8 - inst. V34104 sept2015 printed in usa important notice this product has been tested and complies with the specifications for a class b digital device, pursuant to part 15 of the fcc rules. These limits are designed to provide reasonable protection against harmful interference in a residential i...