Safety Track UCIT 4 Installation And Configuration Manual

Other manuals for UCIT 4: User Manual

Summary of UCIT 4

  • Page 1

    Safety track 249 main street belleville, mi 48111 888-286-9829 1 safety track ucit 4 channel dvr installation and configuration manual version 1.0.2 august, 2013.

  • Page 2

    Safety track 249 main street belleville, mi 48111 888-286-9829 2 table of contents product features………………………………………………………………………………………………………………………………3 specifications………………………………………………………………………………………………………………………………….. 4 product diagram………………………………………………………………………………………………………………………………5 front panel…………………...

  • Page 3

    Safety track 249 main street belleville, mi 48111 888-286-9829 3 product features • 4 channel mobile dvr system with live streaming video, audio, and gps tracking. • indoor and outdoor cameras to give true 360° viewing coverage. • video output for external monitor/in-dash stereo connectivity. • indu...

  • Page 4

    Safety track 249 main street belleville, mi 48111 888-286-9829 4 specifications item description video format ntsc pal video input 4ch input bnc/ harness connector audio input 1ch input / harness connector video output 1ch output bnc / harness connector audio output 1ch output rca / harness connecto...

  • Page 5

    Safety track 249 main street belleville, mi 48111 888-286-9829 5 product diagram front panel rear panel ir receiver compact flash 1 compact flash 2 power indicator recording indicator gps indicator ir extension bnc video in video out usb gps antenna audio out aux power in 12-28v ‘alarm’ input 4-pin ...

  • Page 6

    Safety track 249 main street belleville, mi 48111 888-286-9829 6 wiring diagrams 12-28v alarm input (alarm functionality outlined on page 14) audio input/output 1. Alarm input 1 2. Alarm input 2 3. Alarm input 3 4. Alarm input 4 5. Chassis ground 1. Chassis/signal ground 2. Audio output (to speaker ...

  • Page 7

    Safety track 249 main street belleville, mi 48111 888-286-9829 7 4-pin video cable harness power harness *note: when connecting wiring harness, the chassis ground should be an isolated connection to a true chassis ground not tapped into an existing ground circuit. The signal ground connections can b...

  • Page 8

    Safety track 249 main street belleville, mi 48111 888-286-9829 8 unit installation mounting dvr mount the dvr unit inside the vehicle, with the below considerations: • unit should be mounted in an area that has no exposure to potential moisture • when mounting unit, choose a location that will deter...

  • Page 9

    Safety track 249 main street belleville, mi 48111 888-286-9829 9 system configuration unit remote overview menu screen overview the below images are the menu options of the dvr which will be outlined in the following sections. Channel 3 channel 4 mute channel 1 channel 2 record start/stop quad view ...

  • Page 10

    Safety track 249 main street belleville, mi 48111 888-286-9829 10 encoding settings the encoding settings determine the video quality and compression for live streaming. These settings will be set by safety track prior to shipment, and should not be modified at any time. Modifying these settings can...

  • Page 11

    Safety track 249 main street belleville, mi 48111 888-286-9829 11 plate number the plate number setting is not used on the dvr, it is set on the back end by safety track. This setting is to give the dvr a unique identifier (e.G. Truck 38) for easy identification. Compact flash card format the format...

  • Page 12

    Safety track 249 main street belleville, mi 48111 888-286-9829 12 power management the power management setting is used to set the time the dvr will continue to record after the vehicle has been shut off. By default, safety track sets this time to 15 minutes. The maximum time the dvr will record aft...

  • Page 13

    Safety track 249 main street belleville, mi 48111 888-286-9829 13 dvr serial number the dvr serial number option shows the sn of the device. This number is how the dvr identifies itself with the streaming servers at safety track. This option will only be used during device troubleshooting with suppo...

  • Page 14

    Safety track 249 main street belleville, mi 48111 888-286-9829 14 12-28v ‘alarm’ input the alarm input setting is for dvrs that have an external monitor. This option is to tell the osd to train to one camera when a voltage input is received. This option can be used for backup cameras, blind spot cam...

  • Page 15

    Safety track 249 main street belleville, mi 48111 888-286-9829 15 on screen display (osd) camera views by default, the osd will display the default setting that was defined in the osd settings in the dvr menu. To change the osd to fix on a particular camera, press the corresponding channel key on th...

  • Page 16

    Safety track 249 main street belleville, mi 48111 888-286-9829 16 playback mode for dvrs with an external monitor, the video files stored on the cf card can be viewed directly from the device. Accessing playback mode to access the playback mode of the dvr, press the play button on the dvr remote. Re...

  • Page 17

    Safety track 249 main street belleville, mi 48111 888-286-9829 17 support safety track would like to thank you again for your purchase of our ucit mobile dvr. We are confident our device will provide you streaming video for years to come with the proper care. Should you have any technical issues or ...