Sagitter HYP006WW User Manual

Manual is about: LED WASH LIGHT (C+W)

Summary of HYP006WW

  • Page 1

    1 light( c+w) user manual le d was h.

  • Page 2: 1.Before You Begin

    2 1.Before you begin what is included Ø 1 x fixture Ø 1 x power cable with plug Ø 1 x user manua unpacking instructions immediately upon receiving a fixture, carefully unpack the carton; check the contents to ensure that all parts are present, and have been received in good condition. Notify the shi...

  • Page 3

    3 safety instructions ! Warning! Please read these instructions carefully, which includes important information about the installation, usage and maintenance of this product.. The following symbols are used to identify important safety information on the product and in this manual: ! ! Danger! Safet...

  • Page 4: 2.Introduction

    4 2.Introduction specifications l voltage rating: ac100v 240v 50-60hz l power rating: 90w l led quantity: 36 psc leds(18cool white+18 warmwhite) l led: 670ma l beam angle: 20°/30° /40°(option) l ingress protection: ip65 /indoor(option) l product size: 255 x 205 x290mm l package size: 315x280x345 mm ...

  • Page 5: Product Overview

    5 product overview power in power out dmx in dmx out control board safety dimensions hanging bracket/ floor stand bracket adjustment knob 290

  • Page 6: 3.Setup

    6 3.Setup installation requirement l this product can be used in a variety of situations, can hang and put on the ground. L if hanging the fixture for over head use, then please follow the below steps. L please choose the suitable location to put or hang the light when installing it. You must use th...

  • Page 7

    7 connection of dmx signal wire 1 please use the fixture controller wire specially when use the dmx512 controller. Connect the (male) 3 pin connector side of the dmx cable to the output (female) 3 pin connector of the first fixture. 2 connect the end of the cable coming from the first fixture which ...

  • Page 8: 4.Operating Instructions

    Main function sub- function selection 000~255 (0 ~ 100%) 00~20 01~03 001~512 07ch 02ch 03ch on~off on~off off dim1/2/3/4 password 1.31 instruction select strobe frequency 3 auto programs available set dmx start address sets the operating mode for the fixture:to receive signal from a dmx controller (...

  • Page 9: Control Panel Functions

    9 control panel functions button mode enter up down function exits from the current menu or function enables the currently displayed menu or sets the currently selected value in to the selected function navigates upwards through the menu list and increases the numeric value when in a function naviga...

  • Page 10: Dmx512 Controller Mode

    10 dmx512 controller mode 1 dmx operate mode setting access control panel function by pressing mode until is displayed. Press enter, press up/down buttons until the is displayed. Press enter, press mode return to menu 2 setting dmx512 address Ü 001--512 access control panel function by pressing mode...

  • Page 11: Dmx512 Channel Values

    11 03 channels note:channels 2, 3 control the intensity ratio of each of the cool & warm white leds. Channels 1&2 &3 can be combined together to create multiple white ct color combinations channel 1 dimming 2 cool white 3 warm white value 000~255 000~255 000~255 description 0-100% 0-100% 0-100% chan...

  • Page 12

    12 id address selection value 000~009 010~019 020~029 030~039 040~049 050~059 060~069 070~079 080~089 090~099 100~109 110~119 120~129 130~139 140~149 150~159 160~169 170~179 180~189 190~199 200~209 210 211 function all ids id1 id2 id3 id4 id5 id6 id7 id8 id9 id10 id11 id12 id13 id14 id15 id16 id17 i...

  • Page 13: Id Address Instructions

    13 master dimmer channels 1 controls the intensity of the currently projected color when the slider is at the highest position (255), then the intensity of the output is at themaximum. Cool white and warm white selection channels 2, 3 control the intensity ratio of each of the cool & warm white leds...

  • Page 14: Master/slave Control Mode

    14 select 07channel on fixture's control panel (please refer to dmx512 channels selection). The figure above shows a simple dmx layout which has used three units at each dmx address. The three units have different id addresses. In the dmx address: 001, the user can control the first three lights sim...

  • Page 15: 5. Appendix

    15 5. Appendix service maintenance guide symptom(s) 1 or more led's are not illuminating possible solution(s) clean the fixture regularly to avoid any such failure. This fixture is convection cooled, which means that if the surface is kept clean and free of debris, then proper cooling will be allowe...

  • Page 16: Blow-Out Diagram.

    16 blow-out diagram. 1 2 3 4 5 6 7 8 9 10 11 12 13 description glass cover led lens assembly led metal-core pcb assembly electronic transformer led driver pcb (master) display pcb display clear plastic cover display watertight seal house power socket dmx socket bracket assembly bracket adjustment me...