Sailor AP5065 Installation Manual

Manual is about: Alarm Panel

Summary of AP5065

  • Page 1

    Sailor ap5065 alarm panel installation manual.

  • Page 3: Contents

    1 0824 disclaimer any responsibility or liability for loss or damage in connection with the use of this product and the accompanying documentation is disclaimed by thrane & thrane. The information in this manual is provided for information purposes only, is subject to change without notice, may cont...

  • Page 4

    2 0715.

  • Page 5: Introduction

    3 0736 introduction general description the gmdss distress alarm panel is used for remote initiation of distress alert transmissions and visible and audible indication of incoming distress and urgency calls on vhf, mf/hf, and inmarsat-c. Normally it is installed on the bridge at the conning position...

  • Page 6: Technical Data

    4 0715 technical data general illuminated red distress button with transparent cover for each section. Indicator alarm panel with distress annunciator and status information for each connected unit. Audible alarm for indication of distress alert transmission in progress, or distress or urgency calls...

  • Page 7: Operation

    5 0736 operation distress sending distress alert open the key cover and press the ‘distress’ push button for minimum 5 seconds. The alert button and the selection annunciator for the active unit flashes, and the buzzer sounds periodically. When the distress alert transmission starts, the distress bu...

  • Page 8: General

    6 0715 general test the alarm panel pressing and holding the test button will make all light indicators and alarm buttons flash. Pressing any other button while holding the test button, will sound the buzzer enabling verification of the buttons and the audible indicator. Note that this only tests th...

  • Page 9: Installation

    7 0824 installation connector overview 40708 option vhf 2 vhf 1 mf/hf dc supply inm-c 1 inm-c 2 the alarm panel will connect to 5 transceiver units (2 × vhf, 2 × inmarsat-c, and 1 × mf/ hf) each of which is provided a dedicated connector on the rear side of the alarm panel. Auxiliary interfaces the ...

  • Page 10

    8 0736 interconnecting more alarm panels 40715 24v 24v interconnected panels cable length 24v 24v 24v 24v inmarsat-c 1 vhf 1 inmarsat-c 2 vhf 2 mf/hf alarm panel 1 alarm panel 2 alarm panel 3 up to 3 alarm panels can be interconnected and placed in different locations on the vessel. Interconnected a...

  • Page 11

    9 wiring interconnected alarm panels 40714a alarm panel 1 alarm panel 2 alarm panel 3 10 11 12 13 22 23 24 25 8 9 option dc supply option option inter s inter c inter h inter l * 120 10 11 12 13 22 23 24 25 10 11 12 13 22 23 24 25 120 * * note: the terminator resistor must match the cable used 120 i...

  • Page 12: Wiring To Vhf 1 Or Vhf 2

    10 wiring to vhf 1 or vhf 2 40712 l e n a p m r a l a 3 x ' f h v ' y a w 9 b u s - d n o i t a n g i s e d f h v s u b - c r a p s y a w 5 1 b u s - d t n e m m o c 3 + s u b - c r a p s 2 r i a p d e t s i w t 5 - s u b - c r a p s 3 2 d n g 6 9 v 2 1 + 7 ² m m 5 . 0 x 2 x 2 : e p y t e l b a c m ...

  • Page 13: Wiring to Mf/hf

    11 wiring to mf/hf 40711 l e n a p m r a l a 4 x ' f h / f m ' y a w 9 b u s - d n o i t a n g i s e d f h / f m x u a y a w 9 b u s - d t n e m m o c 3 + s u b - c r a p s 1 r i a p d e t s i w t 5 - s u b - c r a p s 6 2 d n g 5 9 v 4 2 + 7 ² m m 5 . 0 x 2 x 2 : e p y t e l b a c m 0 0 1 . X a m :...

  • Page 14

    12 wiring to inmarsat-c 1 or inmarsat-c 2 (mini-c) 40710 alarm panel mini-c inm-c designation comment d-sub 9 way j302 1,2 gnd gnd 3,7 data + data + 4,5 data - data - 8,9 vcc in +9v cable type: min. 2 x 2 x 0.2mm2 screened. Length: max 250m twisted pair note 1: the cable shield must be connected to ...

  • Page 15: Wiring to 24V Dc Supply

    13 0736 wiring to 24v dc supply 40716a alarm panel alarm panel dc supply designation option d-sub 9 way connector 6 dc - 7 dc + 8 inter-cout 12 (note) 9 inter-sout 13 (note) cable type: 2 x 0.5mm2 screened. Length: max. 100m wiring: 2 x 0.2mm2. Length: 0.15 - 0.2m note: interface supply used only if...

  • Page 16: Outline and Dimension

    14 outline and dimension 40674a 100 128 100 141 60.5 31.5 space for cable entry min. 150 mounting option drilling plan 40722 86 30 109.2 45 7.5 11.6 tilting ± 45 ° 4 x ø 4.5 dimensions are in mm. Weight: ap5065 0.8 kg 0736.

  • Page 17

    15 alarm panel with mounting bracket 40723b 140 120 panel mounting kit (option) part no 405065a-920 9.6 space for cable entry min. 150 drilling plan 105 105 6 108 128 6 4 x ø5 17.5 7.5 4 x ø3.5 uns for m3 iso 14581 20 20 4 pcs m4x30 4 pcs m3x30 3 pcs m3x8 cut out drilling plan 0736.

  • Page 18

    16 appendix a - the aux interface the ap5065 alarm panel is equipped with an auxiliary rs-422 line with a separate rx and tx port, that can be connected to external equipment for monitoring of the alarm panel state. The two ports are called the aux-listener (rx) and the aux-talker (tx), and each has...

  • Page 19

    17 the alr sentence used in ap5065 the talker port sends out an alr sentence every 5 seconds for each for the connected and active systems (i.E., systems that show up on the front display of the alarm panel). If all five systems are active, this gives a combined rate of one sentence every second; if...

  • Page 20

    18 the ack sentence used in ap5065 the alarm panel accepts the following sentence on the listener port: $aaack,id*hh • is the talker id. This is disregarded by the alarm panel and may be set to any two- letter combination. • is the alarm number id. This is also disregarded by the alarm panel and may...

  • Page 24

    Thrane & thrane a/s • info@thrane.Com • www.Thrane.Com tt-98-125065-thr-d issue: 0824.