Sailor RT2047 Technical Manual - page 63
Other manuals for RT2047:
User Manual, Technical Manual
Manual is about: compact 2000 programme
of
124
2 CIRCUIT DESCRIPTION
RT2047 DSC - PART II
2.9
FILTER UNIT MODULE 9/900
The function of the Filter unit is to protect the set against RF interference from equipment installed near
the set. The two options AUX II and SELCALL RELAY requires the relays RE1-9 and RE2-9. These relays
are not a standard feature and can, if needed, be acquired from SP-Radio ( order number 21.300 ).
The function of jumper P34-9 is described in part I, section 2.9 Special Options.
PAGE 2-29