SAINT-GOBAIN PFD4 AstiPure Operating Instructions Manual

Manual is about: series 3

Summary of PFD4 AstiPure

  • Page 1

    Pfd4/pfs4 – operating instructions index date n° 03 22/04/02 dc04020us pump pfd4/pfs4 operating instructions saint-gobain performance plastics asti saint-gobain performance plastics asti (headquarters) (factory) 41, boulevard des bouvets e.A.D.A.C. Des berthilliers f-92741 nanterre cedex f-71850 cha...

  • Page 2

    Pfd4/pfs4 – operating instructions index date n° 03 22/04/02 dc04020us index page i – general 2 i.1 – introduction i.2 – materials i.3 – operation i.4 – pump data ii – quick checklist 2 ii.1 – shipment ii.2 – receipt iii – installation and operation 3 iii.1 – testing iii.2 – set up iii.3 – connectio...

  • Page 3

    Pfd4/pfs4 – operating instructions index date n° 03 22/04/02 dc04020us 2/8 thank you for choosing our saint-gobain performance plastics asti astipure™ model pfd4 pump, series 3 (or pfs4: slurry applications). I – general i.1 – introduction the model pfd/pfs is a pneumatically operated teflon ® pump....

  • Page 4

    Pfd4/pfs4 – operating instructions index date n° 03 22/04/02 dc04020us 3/8 ii.2 – reception upon receipt of the pump, please check that: • the carton has not been damaged in transit. If there is any visible damage, immediately contact the carrier. • the pump is not damaged. If there are signs of dam...

  • Page 5

    Pfd4/pfs4 – operating instructions index date n° 03 22/04/02 dc04020us 4/8 • pfd4 325 or pfs4 325 : incorporates a flanged fitting pn10 dn25. Both the inlet and outlet fittings can be turned over if necessary, by loosening the nuts on the inlet and outlet manifolds (p/n 2430m or 2435m, mark g). For ...

  • Page 6

    Pfd4/pfs4 – operating instructions index date n° 03 22/04/02 dc04020us 5/8 iv.4 – applications the pfd4/pfs4 pump is a volumetric pump. Each impulse delivers a constant unit stroke (about 900 cc/unit stroke). A leak detector (in case of bellows failure) can be fitted on each pump body (female thread...

  • Page 7

    Pfd4/pfs4 – operating instructions index date n° 03 22/04/02 dc04020us 6/8 before dismantling the pump, check the following: • the air/nitrogen supply is off, • the chemical and discharge lines are empty, and there is no pressure, • all in line valves are closed, • you follow your local health and s...

  • Page 8

    Pfd4/pfs4 – operating instructions index date n° 03 22/04/02 dc04020us 7/8 vi – dismantling and repair attention: part numbers quoted in this manual are those used on a “standard” pfd/pfs pump. Before ordering, please check the spare parts list, the section view of the pump and the part numbers tabl...

  • Page 9

    Pfd4/pfs4 – operating instructions index date n° 03 22/04/02 dc04020us 8/8 caution : to tighten the 16 nuts, you need a torque wrench (tightening couple: 7 n.M - cross tightening) . Vi.3.3 – replacing the central shaft and shaft o.Rings disassemble the shuttle valve system (see vi.3.1, step 3) and f...

  • Page 10

    Pfd4/pfs4 – spare parts list index date n° 03 22/04/02 dc04020us saint-gobain performance plastics asti 41 boulevard des bouvets f- 92000 nanterre tel: +33 (0) 1.55.68.59.59 fax: +33 (0) 1.55.68.59.68 http://www.Astipure.Com http://www.Plastics.Saint-gobain.Com pfd4 pump (series 3) & pfs4 part numbe...

  • Page 11

    Pfd4/pfs4 – sapre parts list index date n° 03 22/04/02 dc04020us saint-gobain performance plastics asti 41 boulevard des bouvets f- 92000 nanterre tel: +33 (0) 1.55.68.59.59 fax: +33 (0) 1.55.68.59.68 http://www.Astipure.Com http://www.Plastics.Saint-gobain.Com pfd4 pump (series 3) & pfs4 part numbe...

  • Page 12

    Pfd4/pfs4 – maintenance kits index date n° 03 22/04/02 dc04020us saint-gobain performance plastics asti 41 boulevard des bouvets f- 92000 nanterre tel: +33 (0) 1.55.68.59.59 fax: +33 (0) 1.55.68.59.68 http://www.Astipure.Com http://www.Plastics.Saint-gobain.Com pump pfd4 (series 3) – maintenance kit...

  • Page 13

    Pfd4/pfs4 – maintenance kits index date n° 03 22/04/02 dc04020us saint-gobain performance plastics asti 41 boulevard des bouvets f- 92000 nanterre tel : +33 (0)1.55.68.59.59 fax : +33 (0)1.55.68.59.68 http://www.Astipure.Com http://www.Plastics.Saint-gobain.Com pump “pfd4…g” – maintenance kit p/n “p...

  • Page 14

    Reference indice dessiné par : en date du : designation j.Be astipure pump 4 app4ref 01 saint-gobain performance plastics asti 41 boulevard des bouvets 92000 nanterre - france tel: +33 (0)1 55 68 59 59 fax: +33 (0)1 55 68 59 68 http://www.Astipure.Com tm 14/09/01 vérifié par : en date du : 4x 2633 2...

  • Page 15

    Part numbers table piloting fluid size connection sealing option a b c d e f g h i pf (standard) d 4 2493 6530 2491s 2629 2630 2 x 2632s 2471 2 x 2632k s 4 2309s 2629a 2630a 2 x 2632s 2 x 2632k 322 2430m ms11" 325 2435m w 6530 2593 4 x 2592 2591m or 2599m k 6530 2491k 4 x 2632k g 6530 2593 2430g or ...

  • Page 16

    Reference indice dessiné par: validé par: date: designation fm 12/07/00 astipure pump 4 app 4 ext 00 s s s sg g g gp p p pp p p pl ll l a a a as s s st t t tiiii 41 boulevard des bouvets f-92741 nanterre cedex france tel: +33 (0)1 55 68 59 59 fax: +33 (0)1 55 68 59 68 264m m 10. 39" 360.8mm 14.20" 2...

  • Page 17

    Astipure™ pfd4 pump flow rate characteristics 0 0,5 1 1,5 2 2,5 3 3,5 4 4,5 900 1400 1900 2400 2900 3400 3900 4400 4900 5400 flow rate (l/h) discharge head (bar) air supply 5 bar air supply 4 bar air supply 3 bar air supply 2 bar.

  • Page 18

    Astipure™ pfs4 pump flow rate characteristics 0 0,5 1 1,5 2 2,5 3 3,5 4 4,5 400 900 1400 1900 2400 2900 3400 3900 4400 4900 flow rate (l/h) discharge head (bar) air supply 5 bar air supply 4 bar air supply 3 bar air supply 2 bar.

  • Page 19

    Reference indice dessiné par: validé par: date: designation fm 13/07/00 astipure pump 4 app 4 cab 00 s s s sg g g gp p p pp p p pl ll l a a a as s s st t t tiiii 41 boulevard des bouvets f-92741 nanterre cedex france tel: +33 (0)1 55 68 59 59 fax: +33 (0)1 55 68 59 68 refoulement fluide fluid outlet...