Sakura HBK-18?23AB Operation / installation / service manual

Manual is about: LCD wall-pad remote controller Hand-held remote controller

Summary of HBK-18?23AB

  • Page 1

    Sakura air conditioner user-friendly, earth-friendly evaporative air cooler (operation / installation / service manual) hbk-18・23ds / b ref, s- 116 / 03 / 10 hbk-18・23as / b hbk-18・23bs / b lcd wall-pad remote controller hand-held remote controller.

  • Page 2

    Contents 1 . Safety precautions…………..………………………… 1 2 . Product introduction………………………………… 1 3 . Specifications……………………………..……………… 2 4 . Applicable range………………………………………… 3 5 . Operating environment…………………..…………… 3 6 . Unit parts identifications………………….………… 4 7 . Packing list……………………………………….………… 4 8 . S...

  • Page 3

    1.Do not put your hand or other stuff in the air outlet of the operatin machine.Otherwise,it may cause injury. 2.Do not place heavy object on the unit,keep child away from the unit 3.Do not put gas cooker in the place which the unit can blow directly. Otherwise,it may cause carbon monoxide poisoning...

  • Page 4

    Outdoor air fan cold air water pump evaporation heat exchanger water tank sketch map of operating principle model no . Hbk-18ds/b hbk-23ds/b hbk-18bs/b hbk-23bs/b hbk-18as/b hbk-23as/b max air volume 18000m³/h 23000m³/h 18000m³/h 23000m³/h 18000m³/h 23000m³/h voltage/frequency 380v/50hz current 2.2a...

  • Page 5

    Due to the features of evaporative air cooler,like cooling,humidifing,air exchanging,it's mainly applicable for the places need to be cooling and ventilating,like: 1.Electronic,shoes,printworks,plastic,clothes,printing,packing factories,etc. 2.Texitle,machine,ceramics,chemicals,glasses,hardware,leat...

  • Page 6

    Item name qty. 1 evaporative air cooler 1 2 user's manual 1 to provent injury to the user or other people or property damage,the following instructions must be followed: this symbol indicates caution this symbol indicates never do this this symbol indicates always do this 4 sakura – total air condit...

  • Page 7

    5 sakura – total air conditioning solution.

  • Page 8

    No using in the environment of explosive and flammable meterials keep the unit working in a flat place make the air outlet&inlet not close to wall,curtain,etc.,it may affect the performance only authorised service technician are allowed for repair or maintenance 6 sakura – total air conditioning sol...

  • Page 9

    1.Connect with the power, and the unit will be in stand-by condition. , and press to stop . 2.To cool the air, press 3.To ventilate, press , press to stop. 4.To clean the unit, press , press to stop. . 5.Under the condition of ventilation or cooling, if need swing function,press press it again to st...

  • Page 10

    . Installation methods: 1 installation drawing for down discharge unit 8 sakura – total air conditioning solution 12 installation.

  • Page 11

    Installation drawing for side discharge unit 9 sakur total air conditioning solution a –.

  • Page 12

    Installation drawing for up discharge unit 10 sakura – total air conditioning solution.

  • Page 13

    Mounting bracket planform mounting bracket side view 11 sakur total air conditioning solution a –.

  • Page 14

    2 make sure to read th . Important notice for installation e use instructions and carry out the work by strictly complying with the sed space, the air outlet should be installed, so as to keep the balance of air outlet ( 2 )b stalled horizontally, and the space between machine and wall ( 3) 23ds/b,2...

  • Page 15

    Clean cooling pad disconnect the power,unscrew the 6 screws on the shutter,then pulls the shutter slightly,and ke off the cooling pads assy. Ta attention: do not make too high water pressure,not use acidity or alkalinity detergent ◆ r tank utton after power on and power off after 2 minutes nnect pow...

  • Page 16

    Problem possible causes what to do air cooler does not start 1.The air cooler is unplugged 2.Swithch button does not work 4.Too low voltage 1.Check the power 2.Replace the main control board phase 4.Check the voltage 3.Check the 3.Lack of phase 1.Submerged pump broken 1.Replace the pump fuse blown f...