Salda SIG 6-17 Installation And Maintenance Manual

Manual is about: BRINE-WATER HEAT PUMPS

Summary of SIG 6-17

  • Page 1

    Subject to technical modifi cation sig 6-17 brine-water heat pumps installation and maintenance manual.

  • Page 2

    2 sig 6-17 www.Salda.Lt table of contents 1. Basic information...........................................................................................................3 1.1. Safety notes.............................................................................................................3 1...

  • Page 3

    3 sig 6-17 www.Salda.Lt • setup, installation, confi guration, and initial start up of the heat pump system must be carried out by a qualifi ed tech- nician applying the relevant statutory rules, regulations, and guide- lines, as well as the operating instructions. • the use of the heat pump must be r...

  • Page 4

    4 sig 6-17 www.Salda.Lt our warranty does not cover damages caused by or due to the following reasons: • unsuitable or improper use or operation; • incorrect setup, adjustment, or incorrect initial startup by buyer or third parties; • installation of third party parts; • operating the equipment unde...

  • Page 5

    5 sig 6-17 www.Salda.Lt before every transport, make sure the lifting or transport equipment has the lifting power needed to transport the re- spective equipment weight. All of the tasks described here must be carried out based on the relevant safety standards. This applies to tasks associated with ...

  • Page 6

    6 sig 6-17 www.Salda.Lt the unit may only be installed indoors in rooms with low humidity on a level, smooth and horizontal surface. The en- tire base of the frame should lie directly on the fl oor to ensure a good soundproof seal. If this is not the case, additional sound insulation measures may be ...

  • Page 7

    7 sig 6-17 www.Salda.Lt antifreeze protection for installation locations prone to frost the antifreeze function of the heat pump controller is active whenever the controller and the heat circulating pumps are ready for operation. If the heat pump is taken out of service or in the event of a power fa...

  • Page 8

    8 sig 6-17 www.Salda.Lt attention! Setup, installation, confi guration, and initial start up of the heat pump system must be carried out by a qualifi ed technician applying the relevant statutory rules, regulations, and guidelines, as well as the operat- ing instructions. Electrical circuit diagrams a...

  • Page 9

    9 sig 6-17 www.Salda.Lt all electrical components required for the operation of the heat pump are located on the control panel.For detailed instructions concerning the connection and functioning of the heat pump controller refer to the operating manual sup- plied with the controller. An disconnectin...

  • Page 10

    10 sig 6-17 www.Salda.Lt the ingress of oxygen into the heating water circuit may result in the formation of oxidation products (rust), particu- larly if steel components are used. This oxygen enters the heating system via the valves, the circulating pumps and/or plastic pipes. It is therefore essen...

  • Page 11

    11 sig 6-17 www.Salda.Lt attention! The dirt trap must be inserted in the heat source inlet of the heat pump to protect the evaporator against the ingress of impurities. Clean the dirt trap’s fi lter screen one day after start-up and subsequently in weekly intervals. If no more signs of contamination...

  • Page 12

    12 sig 6-17 www.Salda.Lt before removing the heat pump, disconnect it from the power source and close all valves. Observe all environmen- tally-relevant requirements regarding the recovery, recycling and disposal of materials and components in accordance with all applicable standards. Particular att...

  • Page 13

    13 sig 6-17 www.Salda.Lt pic. 10.1 outside temperature sensor temperature sensor.

  • Page 14

    14 sig 6-17 www.Salda.Lt -6 -4 -2 0 2 4 6 8 10 12 3 4 5 6 7 8 heating capacity heating tout – 35º c heating tout – 50ºc brine in cº po w e r, kw -6 -4 -2 0 2 4 6 8 10 12 1 1,5 2 power consumption heating tout – 35ºc heating tout – 50ºc brine in cº p o w e r ,k w -6 -4 -2 0 2 4 6 8 10 12 2 3 4 5 6 co...

  • Page 15

    15 sig 6-17 www.Salda.Lt -6 -4 -2 0 2 4 6 8 10 12 3 4 5 6 7 8 9 10 11 12 heating capacity heating tout – 35º c heating tout – 50ºc brine in cº po w e r, k w -6 -4 -2 0 2 4 6 8 10 12 1 1,5 2 2,5 power consumption heating tout – 35ºc heating tout – 50ºc brine in cº p o w e r ,k w -6 -4 -2 0 2 4 6 8 10...

  • Page 16

    16 sig 6-17 www.Salda.Lt -6 -4 -2 0 2 4 6 8 10 12 6 7 8 9 10 11 12 13 14 heating capacity heating tout – 35º c heating tout – 50ºc brine in cº po w e r, k w -6 -4 -2 0 2 4 6 8 10 12 1 1,5 2 2,5 3 3,5 power consumption heating tout – 35ºc heating tout – 50ºc brine in cº p o w e r ,k w -6 -4 -2 0 2 4 ...

  • Page 17

    17 sig 6-17 www.Salda.Lt -6 -4 -2 0 2 4 6 8 10 12 6 8 10 12 14 16 18 heating capacity heating tout – 35º c heating tout – 50ºc brine in cº po w e r, k w -6 -4 -2 0 2 4 6 8 10 12 1 1,5 2 2,5 3 3,5 4 power consumption heating tout – 35ºc heating tout – 50ºc brine in cº p o w e r ,k w -6 -4 -2 0 2 4 6 ...

  • Page 18

    18 sig 6-17 www.Salda.Lt -6 -4 -2 0 2 4 6 8 10 12 8 10 12 14 16 18 20 heating capacity heating tout – 35º c heating tout – 50ºc brine in cº po w e r, k w -6 -4 -2 0 2 4 6 8 10 12 2 2,5 3 3,5 4 4,5 power consumption heating tout – 35ºc heating tout – 50ºc brine in cº p o w e r ,k w -6 -4 -2 0 2 4 6 8...

  • Page 19

    19 sig 6-17 www.Salda.Lt -6 -4 -2 0 2 4 6 8 10 12 2 3 4 5 6 7 coefficient of performance heating tout – 35ºc heating tout – 50ºc brine in cº c o p -6 -4 -2 0 2 4 6 8 10 12 10 12 14 16 18 20 22 24 heating capacity heating tout – 35º c heating tout – 50ºc brine in cº po w e r, k w -6 -4 -2 0 2 4 6 8 1...

  • Page 20

    20 sig 6-17 www.Salda.Lt pic. 10.4.1.

  • Page 21

    21 sig 6-17 www.Salda.Lt pic. 10.4.2.

  • Page 22

    22 sig 6-17 www.Salda.Lt pic. 10.4.3.

  • Page 23

    23 sig 6-17 www.Salda.Lt marking title quantity s circuit breaker 3p c16 1 s1 circuit breaker 1p c6 1 s2, s3 circuit breaker 1p c2 2 a1 softarter solarstar17 1 q1 thermal relay ns2-25k 9-14a 1 q1 aux contact ns2-ae11 1 fr phase sequence relay rm4 tg20 1 tr1 transformers 230vac/24vdc 1 r1-r6 relay rt...

  • Page 24

    24 sig 6-17 www.Salda.Lt pic. 10.5.1 pic. 10.5.2 domestic hot water direct heating system.

  • Page 25

    25 sig 6-17 www.Salda.Lt pic. 10.5.3 pic. 10.5.4 heating system with buffer tank or hydraulic separator and circulation pump heating system with buffer tank or hydraulic separator, mixing valve and circulation pump.

  • Page 26

    26 sig 6-17 www.Salda.Lt pic. 10.5.5 pic. 10.5.6 domestic hot water and heating systems domestic hot water and heating systems with buffer tank or hydraulic separator and circulation pump.

  • Page 27

    27 sig 6-17 www.Salda.Lt pic. 10.5.7 domestic hot water and heating systems with buffer tank or hydraulic separator, mixing valve and circulation pump.

  • Page 28

    Uab “salda” ragainės g. 100, lt-78109 Šiauliai, lithuania tel. (+370 41) 540415 fax. (+370 41) 540417 offi ce@salda.Lt www.Salda.Lt hereby confi rm that the design and construction of the product(s) listed below, in the version(s) placed on the market by us, conform to the relevant requirements of the...

  • Page 29

    29 sig 6-17 www.Salda.Lt.