Salicru SPS 1000 ADV R User Manual

Manual is about: SPS ADVANCE R Series, SPS ADVANCE T Series, 0,75.. 1,5 kVA & 0,85.. 3 kVA

Summary of SPS 1000 ADV R

  • Page 1

    Sps advance r & t 0,75.. 1,5 kva & 0,85.. 3 kva uninterruptible power supply systems (ups) user manual.

  • Page 2

    2 salicru.

  • Page 3

    3 general index. 1. Introduction. 1.1. Thank you letter. 2. Safety information. 2.1. Using this manual. 2.1.1. Conventions and symbols used. 3. Quality assurance and standards. 3.1. Statement by the management. 3.2. Standards. 3.3. Environment. 4. Presentation. 4.1. Views. 4.1.1. Views of the device...

  • Page 4

    4 salicru salicru 1. Introduction. 1.1. Thank you letter. We thank you in advance for the trust placed in us in the pur- chasing of this product. Read this instruction manual carefully in order to familiarize yourself with its content, since the more you know and understand the equipment the greater...

  • Page 5

    5 2. Safety information. 2.1. Using this manual. The documentation of any standard equipment is available to the customer on our website for download (www.Salicru.Com) . • for devices “powered by socket”, this is the website for obtaining the user manual and “safety instructions” ek266*08. • for dev...

  • Page 6

    6 salicru 3. Quality assurance and standards. 3.1. Statement by the management. Our goal is customer satisfaction, therefore this management has decided to establish a quality and environment policy, through the implementation of a quality and environmental management system that will enable us to c...

  • Page 7

    7 4. Presentation. 4.1. Views. 4.1.1. Views of the device. Fig. 1 and fig. 2 correspond to sps advance r devices and fig. 3 and fig. 4 to sps advance t devices. However, because the product is constantly evolving, discrepancies or slight contra- dictions may arise. If in any doubt, the labelling on ...

  • Page 8

    8 salicru 4.1.1.2. Views of the sps advance t device. 850 to 2000 va models. Control panel with lcd display plastic front trim front view of the device. 3000 va models. Control panel with lcd display plastic front trim front view of the device. Batteries modules for 1000 to 2000 va models. Plastic f...

  • Page 9

    9 850 to 2000 va models. Fan iec ac output sockets smart slot protective cover rs232 com port for connection to external epo ac power protection breaker iec ac input connector usb com port rear view of the standard device. 1000 to 2000 va b1 models. Fan iec ac output sockets smart slot protective co...

  • Page 10

    10 salicru battery modules for 1000 to 2000 va devices. Vdc protection cover module input connector module output connector rear view of the battery module. Battery module for 3000 va devices. Vdc protection cover module input connector cover module output connector cover rear view of the battery mo...

  • Page 11

    11 note related to b1 batteries: (b1) device with a more powerful charger, which does not have a battery pack, nor the possibility of in- stalling them in the same box. If an accumulator module is required, it will need to be ordered as a separate item, which will be connected to the ups using the s...

  • Page 12

    12 salicru model type input/output type sps 850 adv t standard single-phase / single-phase. Sps 1000 adv t sps 1500 adv t sps 2000 adv t sps 3000 adv t sps 1000 adv t (b1) long backup with additional charger sps 1500 adv t (b1) sps 2000 adv t (b1) sps 3000 adv t (b1) tab. 2. Sps advance t standardis...

  • Page 13

    13 5. Installation. • read and respect the safety information, described in chapter 2 of this document. Failure to obey some of the instructions described in this manual can result in a serious or very serious accident to persons in direct contact or in the vicinity, as well as faults in the equipme...

  • Page 14

    14 salicru 5.1.4.1. Rack-type mounting in a 19” cabinet (sps advance r devices). • proceed as follows (see fig. 7): using the supplied screws, fix the two adapter angles for use as handles on each side of the ups, respecting its mounting orientation. To install the device in a rack cabinet, it is ne...

  • Page 15

    15 • this device is suitable for installation in networks with tt, tn-s, tn-c or it power distribution sys- tems, taking into account at the time of installation the particularities of the system used and the national elec- trical regulations of the destination country. • advance r and t models feat...

  • Page 16

    16 salicru model rated voltage of batteries minimum values, fast type fuses dc voltage (v) current (a) sps 1000 adv t (12 v x 2 ) = 24 v 125 50 sps 1500 adv t 63 sps 2000 adv t 100 sps 3000 adv t (12 v x 4 ) = 48 v 63 tab. 3. Protection features between device and battery module. • before starting t...

  • Page 17

    17 5 1 9 6 2 1 3 4 fig. 10. Db9 connectors for rs232 and usb. 5.2.7. Smart slot for the integration of an electronic communication unit (snmp). • the corresponding documentation is supplied with the op- tion. Read it before starting installation. Installation. • remove the protective cover from the ...

  • Page 18

    18 salicru 6. Operation. 6.1. Startup. 6.1.1. Checks before start-up. • make sure that all of the connections have been made cor- rectly, following the instructions on the labelling of the de- vice and in chapter 5. • make sure that all loads are ‘off’. Check that all loads are ‘off.’ do not start t...

  • Page 19

    19 7. Control panel with lcd display. 7.1. Composition of the control panel with lcd display. • the control panel consists of: two buttons with the functions described in tab. 6. An lcd display with backlighting. Sps advance r display. On/off sps advance t display. On/off fig. 11. View of the sps ad...

  • Page 20

    20 salicru tables 7, 8 and 9 show the information that appears on the display depending on the working mode of the ups. • information represented in line mode. Select sw button state of the ups level value input voltage backup time battery level output voltage charge level start v x x - v v v v 1st ...

  • Page 21

    21 • information represented in battery mode. Select sw button state of the ups level value input voltage backup time battery level output voltage charge level start x v x - v v v v 1st click x v x - v v v 2nd click x v x - v v v v 3rd click (return to start) x v x - v v v v press > 3 sec (disable a...

  • Page 22

    22 salicru 8. Maintenance, warranty and service. 8.1. Battery maintenance. • pay attention to all of the safety instructions concerning batteries indicated in section 1.2.3 of manual ek266*08. • the service life of the batteries greatly depends on the am- bient temperature and other factors such as ...

  • Page 23

    23 symptom possible cause solution a66 epo activated: open epo terminals connect epo terminals a68 overtemperature: ambient temperature too high. Disconnect non-essential loads from device. Check that fan is working correctly and that ups’s air inlets and outlets have not been blocked. A86 low inver...

  • Page 24

    24 salicru 9. Annexes. 9.1. General technical specifications. Models. Advance r available power ratings (va / w). 750va / 450w 1000va / 600w 1500va / 900w technology. Line-interactive with sine-wave output. Input. Input type. Single-phase. Number of cables. 3 cables - phase r (l) + neutral (n) and e...

  • Page 25

    25 models. Advance r available power ratings (va / w). 750va / 450w 1000va / 600w 1500va / 900w marking. Ce quality and environmental management. Iso 9001 and iso 140001 (certified by sgs) tab. 14. Advance r general technical specifications. Models. Advance t available power ratings (va / w). 850va ...

  • Page 26

    26 salicru models. Advance t available power ratings (va / w). 850va / 595w 1000va / 700w 1500va / 1050w 2000va / 1400w 3000va / 2100w relative humidity. 0..90 % non-condensing. Protection rating. Ip20 dimensions (mm) depth × width × height. Ups modules. 327 x 140 x 191 416 x 196 x 342 optional batt...

  • Page 27

    27 diodes, whether solid state semiconductors, vacuum valves or gaseous valves, such as those containing mercury va- pour. Depending on the characteristics of the ac power that they use, they are classified as single-phase when they are powered by a mains phase or three-phase when they are powered b...

  • Page 28

    Avda. De la serra 100 08460 palautordera barcelona tel. +34 93 848 24 00 fax +34 93 848 22 05 services@salicru.Com salicru.Com www.Linkedin.Com/company/salicru @salicru_sa product range uninterruptible power supplies (ups) lighting flow dimmer-stabilisers dc power systems static inverters photovolta...