Salicru SPS SOHO+ series User Manual

Summary of SPS SOHO+ series

  • Page 1

    Uninterruptible power supply (ups) + lighting flow dimmer stabilizers (iluest) + switch mode power supply + static inverters + photovoltaic inverters + voltage stabilizers and power line conditioners sps soho+ series user’s manual uninterruptible power supply.

  • Page 3: General Index

    3 salicru general index 1. Introduction. 1.1. Acknowledgement letter. 1.2. Using this manual. 1.2.1. Conventions and used symbols. 1.2.2. For more information and/or help. 1.2.3. Safety instructions. 1.2.3.1. General safety warnings. 1.2.3.2. To keep in mind. 1.2.3.3. Safety warning regarding batter...

  • Page 4: 1.  Introduction.

    4 salicru 1. Introduction. 1.1. Acknowledgement letter. We would like to thank you in advance for the trust you have placed in us by purchasing this product. Read this instruction manual carefully before starting up the equipment and keep it for any possible future consult that can arise. We remain ...

  • Page 5

    5 salicru • the equipments provided with power cord with plug and outlets, can be connected and used by personnel without any kind of experience. The equipments with power blocks have to be installed by qualified personnel and it can be used by personnel with not specific training, just with only he...

  • Page 6

    6 1.2.3.2. To keep in mind. • do not try to dismantle or change any part of the equipment, if this action is not contemplated in this document. Manipulation inside the sps due to any modifica- tion, reparation or any other cause, can make an electrical discharge of high voltage and it is restricted ...

  • Page 7

    7 salicru for an optimum and efficient operating, the battery set has to be located as close as possible to the equipment. • the battery voltage can involve the risk of electric shock and can produce high short circuit currents. Ob- serve the following preventive measures before manipulating any ter...

  • Page 8: 2.  Quality And Standard

    8 2. Quality and standard guarantee. 2.1. Declaration of the management. Our target is the client’s satisfaction, therefore this management has decided to establish a quality and environmental policy, by means of installation a quality and environmental management system that becomes us capable to c...

  • Page 9: 3.  Presentation.

    9 salicru 3. Presentation. 3.1. Views. 3.1.1. Views of the equipment. Figures 1 to 4 show the illustrations of the equipment according to the case format and depending on the power of the model. Nevertheless and due to the constant evolution of the product, some discrepancies or small contradictions...

  • Page 10

    10 3.2. Synoptic with lcd display. As it is possible to be observed in the following figure, the equip- ment has a standart lcd display, where are reflected the input tension and frequency, output voltage and frequency and the fault indicators, load level, battery capacity, line and battery modes. I...

  • Page 11: 4.  Installation.

    11 salicru 4. Installation. • check the safety instructions, from section 1.2.3. • check that the data in the nameplate are the required by the installation. • a wrong connection or manoeuvring, can make faults in the sps and/or loads connected to itself. Read carefully the in- structions of this ma...

  • Page 12

    12 4.3. Communication ports. 4.3.1. Description and features. New series soho+ incorporates a port usb with which to com- municate with the outside. 4.3.2. Software. • free software download - winpower. Winpower is a sps monitoring software, which makes a user-friendly interface of monitoring and ma...

  • Page 13: 5.  Operation.

    13 salicru 5. Operation. 5.1. Preliminary controls. • make sure that all connections have been done properly, and respecting the labelling of the equipment and the instructions of chapter 4. • check that the power supply is correct. • check that the sps is off (shutdown). • make sure that all loads ...

  • Page 14

    14 • battery capacity definition: battery bar indication battery voltage ≤ 11 v 11 v ≤ battery voltage ≤ 11,5 v 11,5 v ≤ battery voltage ≤ 12,5 v battery voltagea ≥ 12,5 v battery level table 2. Battery level. • when over load, the mark will flicker every 1 second. • when battery low, the mark will ...

  • Page 15: Service.

    15 salicru 6. Maintenance, warranty and service. 6.1. Basic maintenance guide. The main guidelines for a correct maintenance are similar to the ones that are applying our service and technical support in the preventive maintenance modality (see section 6.5). 6.2. Battery maintenance. • pay attention...

  • Page 16

    16 6.4.1. Covered product. Sps soho+ series. 6.4.2. Warranty terms. See product conditions as in website. 6.4.3. Out of scope of supply. Our company is not forced by the warranty if it appreciates that the defect in the product doesn’t exist or it was caused by a wrong use, negligence, installation ...

  • Page 17: 7.  Annexes.

    17 salicru 7. Annexes. 7.1. General technical specifications. Model sps.400.Soho+ sps.600.Soho+ sps.800.Soho+ sps.1000.Soho+ sps.1400.Soho+ sps.2000.Soho+ capacity va / w 400 / 240 600 / 360 800 / 480 1000 / 600 1400 / 840 2000 / 1200 input voltage 220, 230, 240 vac 230, 240 vac voltage range 162-29...

  • Page 18

    18 nating current. In the direct current is almost equal to the real power but in the alternating current it can be different de- pending on the power factor. The voltamperes are arithmetic product of the multiplication between the voltage and current. • lcd.- lcd are the english acronyms of liquid ...

  • Page 19

    19 salicru : .................................................................................................................................................................................................................... .............................................................................

  • Page 20

    Uninterruptible power supply (ups) + lighting flow dimmer stabilizers (iluest) + switch mode power supply + static inverters + photovoltaic inverters + voltage stabilizers and power line conditioners avda. De la serra, 100 08460 palautordera barcelona tel. +34 93 848 24 00 902 48 24 00 (only spain) ...