Salter Brecknell B220 User Instructions

Other manuals for B220: Service Manual
Manual is about: Counting Scale

Summary of B220

  • Page 1

    B220 user instructions brisch number 76103-383 issue 1 11/07/01 english *76103-383* counting scale.

  • Page 3: Warnings

    Table of contents warnings 1 cleaning the scale 1 installation 1 switching the scale on 2 bleeps 3 testing the display/selecting sleep mode 3 error messages 3 4 zeroing the scale 4 using the clear key 4 clearing a numeric entry 4 4 creating a tare 4 creating a keyboard entered tare 4 cancelling a ta...

  • Page 4: Using Plus

    Batch counting 8 totalising 8 9 programming a plu hot key 9 programming a keyboard plu 9 using a plu hot key 9 using a keyboard entered plu 9 clearing a plu hot key 9 clearing a keyboard entered plu 10 clearing a keyboard entered plu 10 user calibration adjustment 10 to cancel a user calibration adj...

  • Page 5: Changing Plus

    Changing the duration of a ‘long’ press 14 changing the minimum sample weight 14 changing the manual re-sampling range 14 changing the automatic re-sampling range 14 14 changing a plu item weight 14 changing a plu tare 15 protecting a plu 15 16 17 changing plus declaration of conformity non-approved...

  • Page 6

    Warnings cleaning the scale installation for your protection, all mains (110v or 230v) equipment used where damp or wet conditions may occur, must be supplied from a correctly fused source and protected by an approved rcd to bs7071 or bs7288 or iec1008-2-2 bs en 61008:1995. If in doubt seek advice f...

  • Page 7: Warning

    Switching the scale on connecting to the mains - plug the adaptor lead into the scale, replace the cover and weighplate and then plug the adaptor into the power supply. : do not use the mains adaptor if it is damaged. Warning using batteries caution: - plug the battery pack into the scale and place ...

  • Page 8

    Bleeps short press (press once) long press (press and hold) testing the display/selecting sleep mode 1 101d 0-6-0 service information: sleep short press x 2 short press long press short press error messages if a persistent error message appears or the scale locks up, disconnect then reconnect the sc...

  • Page 9

    Using the scale zeroing the scale make sure that the scale is at zero before weighing. Short press 0.000 using tares creating a keyboard entered tare 0.000 ce long press using the clear key to clear all active plus, tares and item weights: clearing a numeric entry enter value 1.26 1.2 0 ce short pre...

  • Page 10: Small

    Cancelling a tare t short press t -0.150 net 0.000 sampling the method that you use to sample will depend on whether the items that you intend to count are high or low value and whether the items vary slightly in weight: small sample weight* large sample weight* gold coins nuts/ bolts currency notes...

  • Page 11

    =10 normal sampling re-sampling keyboard entered item weights sple 1.345 short press short press short press the scale is now ready for counting. Items added or removed once you have sampled a group of items, you can add an equal or greater amount to the scale and then re-sample. This will increase ...

  • Page 12

    Short press tt counting setting an item limit viewing the item limit clearing the item limit forward counting reverse counting short press number of items you can set an item limit before or after sampling. Short press short press 300 item limit 300 ce short press ? 1.345 4 weight items sample the i...

  • Page 13

    Tt batch counting sample the items to be counted (see page 5). Short press short press tt 0.000 0 net - 0.345 120 net repeat until all batches have been counted weight items totalising sample the items to be counted (see page 5). 0.000 0 net net t n 1 250 net 250 0.128 t n 2 500 number of transactio...

  • Page 14

    Using plus there are thirty five plus that can be programmed to include either a tare, an item weight or both. All plus can be protected to avoid being accidentally changed or cleared in management mode (see page 15). Programming a plu hot key programming a keyboard plu and/or sample or enter an an ...

  • Page 15

    User calibration adjustment ce long press 0.000 0 net plu number long press clearing a keyboard entered plu short press ce short press 6kg capacity any weight in 1kg steps 15/30kg capacity any weight in 1kg steps above a minimum of 12% of scale capacity to cancel a user calibration adjustment c shor...

  • Page 16: 6231

    Ce management mode branch sub-branch value 19.00 1 6231 enter management mode go to the next branch (long press) go to next sub-branch (short press) go to the previous branch (long press) go to previous sub-branch (short press) select value to be changed (short press) return to branch 00 (long press...

  • Page 17: Enabled

    Intelligent filter setup automatic zero self balance scale automatically re-zeros if a consistent negative gross weight is detected disabled 6.03 0 enabled 6.03 1 disabled 6.01 0 fast wide mode 6.01 1 slow wide mode 6.01 3 fast narrow mode 6.01 5 slow narrow mode 6.01 7 zero tracking this is used to...

  • Page 18: 0 = None

    Switching the keyboard bleeper on/off go to branch 19, sub-branch 01 0 = off = on 1 19.01 1 error bleeper go to branch 19, sub-branch 03 0 = off = on 1 19.03 1 changing the bleeper volume go to branch 19, sub-branch 04 0 = quiet = loud 1 19.04 1 0 = always off 1 = 5 seconds 2 = 1 minute 3 = 5 minute...

  • Page 19: 150

    Changing the duration of a 'long' press go to branch 29, sub-branch 00 29.00 200 for example : 200 = 2 seconds 150 = 1½ seconds = ½ second 50 changing the minimum sample weight go to branch 61, sub-branch 00 61.00 10 enter the minimum sample weight in grams. For example: g 10 changing the manual re-...

  • Page 20

    Changing a plu tare go to plu branch number. For example plu5 105.02 145 sub-branch 02 enter the weight (kg) sub-branch 03 enter the number of decimal places 105.03 2 protecting a plu go to the plu branch number. For example plu5 105.04 1 sub-branch 04 0 = not protected 1 = protected 15.

  • Page 21

    Declaration of conformity the non-automatic weighing instrument manufacturer salter brecknell type b220 corresponds to the requirements of the following ec directives: emc directive 89/336/eec low voltage directive 73/23/eec the applicable harmonised standards are: en60 950 en 50 081-1 en 50 082-1 t...

  • Page 22

    Declaration of conformity the non-automatic weighing instrument manufacturer salter brecknell type b220 no. Of ec type approval certificate t5532 corresponds to the requirements of the following ec directives: non-automatic weighing instruments directive 90/384/eec1 emc directive 89/336/eec low volt...