Salter Brecknell PR-3000 Series Operation Manual

Manual is about: Salter Brecknell PR-3000 Series Pallet Jack Digital Scale

Summary of PR-3000 Series

  • Page 1

    Pallet jack digital scale version 1.2 february 13, 2004 contents subject to change without notice. Salter brecknell weighing products 1000 armstrong drive fairmont, mn 56031 tel (800) 637-0529 tel (507) 238-8702 fax (507) 238-8271 e-mail: sales@salterbrecknell.Com web: www.Salterbrecknell.Com..

  • Page 2

    2 table of contents page chapter 1: introduction to the pallet runner 3000 pallet jack scale..................................... 4 chapter 2: getting started.............................................................................................................. 5 chapter 3: operation ...........

  • Page 3

    3 appendix a: specifications................................................................................................................ 18 appendix b: serial port information .................................................................................................. 18 appendix c: error ...

  • Page 4

    4 chapter 1: introduction to the pallet runner 3000 pallet jack scale the pallet runner 3000 series scale is a general purpose, industrial grade pallet weighing scale. Featuring complete portability utilizing 2-6 volt internal batteries, push button tare, and an easy to use piece-counting function. ...

  • Page 5

    5 chapter 2: getting started after unpacking the scale, a small amount of preparation is required before the scale can be used. All pallet runner 3000 models are factory tested and calibrated prior to delivery. 1. Remove all packaging from scale. 2. Position the scale on a firm, flat surface. 3. Low...

  • Page 6

    6 chapter 3: operation 3.1 display the pallet runner 3000 utilizes a 6 digit lcd (liquid crystal display) to display the weight and system information table 3-1 summarizes the display annunciators. 3.1.1 liquid crystal display (lcd) figure 3-1 shows the display detail of the pallet runner 3000 lcd. ...

  • Page 7

    7 3.2 keyboard the keyboard is composed of five function keys. Refer to figure 3-2 for the overall layout and key locations. Zero units tare print net gross off on figure 3-2: function keys layout 3.2.1 function keys units – this key toggles the scale among the available weight units. Available weig...

  • Page 8

    8 3. Raise the empty container or pallet off the floor and allow the weight indication to stabilize. 4. Press the tare key. The display shows zero weight and turns the net annunciator on. 5. Place the material to be weighed on the container or pallet, raise it off the floor and allow the weight indi...

  • Page 9

    9 chapter 4: advanced features and operation 4.1 piece counting this mode is used to indicate the number of pieces of an item you have placed on the scale’s forks and is accessed by pressing the units key. To ensure accuracy, the parts you are counting must be consistent in weight. The scale uses th...

  • Page 10

    10 chapter 5: scale configuration 5.1 scale configuration overview the scale contains two main setup menus: the user (“a”) menu - which configures the serial communication port and enables some user options - and the factory setup (“f”) menu. 5.2 user (“a” & “f”) menus 5.2.1 entering the user menu “...

  • Page 11

    11 user mode key functions net tare units save print zero off gross on figure 5-2: user menu key assignments a15 auto power off off 3 5 10 20 30 figure 5-3: user menu chart 5.2.3 notes on the user menu 1. Detailed descriptions of the user menu parameters can be found in table 5-1. Factory-set defaul...

  • Page 12

    12 5.3 factory setup (“a”) menu table 5-1: user menu chart name/code description code/value a1 baud rate selects the baud rate for the data transmission through both serial ports (com! And com2) 1200 2400√ 4800 9600 a2 data bits and parity selects the number of data bits and parity of serial transmi...

  • Page 13

    13 name/code description code/value f1 graduations specifies number of full-scale graduations. Value should be consistent with legal requirements and environmental limits on the useful system resolution. 500 1,000 1,500 2,000 2,500 3,000 4,000 5,000 6,000 8,000 10,000√ √√√ 12,000 20,000 30,000 40,00...

  • Page 14

    14 name/code description code/value f9 display divisions determines the desired weight increments. Value should be consistent with legal requirements. 1√ √√√ 2 5 f10 decimal pt. Determines location of the decimal point. 0√ √√√ 0.0 0.00 0.000 0.0000 00 f11 custom unit multiplier actuates the function...

  • Page 15

    15.

  • Page 16

    16 chapter 6: scale calibration 6.1 scale calibration overview the pallet runner 3000 scale may be calibrated with any precision test weight between 30 pounds and 3000 pounds. The recommended test weight is 2000 pounds, but in general the larger the test weight, the more accurate the scale will be. ...

  • Page 17

    17 6. If the calibration was not successful, one of the error messages below will appear. Take the indicated action to correct the problem, then perform a new calibration. " err0 " - the calibration test weight or the adjusted keyed-in weight is larger than the full capacity of the scale. Change the...

  • Page 18

    18 appendix a: specifications construction: pallet jack: high tensile steel indicator: a-36 carbon steel display: 6 digit, 7-segment lcd keypad: 5-key tactile keypad over capacity annunciation: 103% of full scale capacity operating temperature range: 14 ° f to 104 ° f (-10°c to 40°c) power source: 2...

  • Page 19

    19 appendix c: displayed error codes code mode meaning / possible solution normal operating mode gross overload. A weight greater than the rated capacity has been applied to the scale. Remove the weight from the platter or try re- calibrating the scale. Otherwise, check for a bad load cell connectio...

  • Page 20

    20 appendix d: notes on recharageable battery d.1 overview your scale contains two internal lead-acid rechargeable batteries connected in parallel. Before using the scale for the first time, please charge the battery overnight. The scale’s battery should operate for about 40 hours if left on continu...