Salter Brecknell S-100 Operation Manual

Manual is about: Model S-100 Floor Scale

Summary of S-100

  • Page 1

    Model s-100 floor scale operation manual manual: xxxxxx issue:xx.

  • Page 2

    ©avery weigh-tronix, llc. All rights reserved. The information contained herein is the property of avery weigh-tronix and is supplied without liability for errors or omissions. No part may be reproduced or used except as authorised by contract or other written permission. The copyright and the foreg...

  • Page 3

    Contents warnings ............................................................................................................................................................ 2 product identification table .................................................................................................

  • Page 4

    Assembly product contents setting the indicator up for use rs232 loadcell socket power/adapter socket power supply connecting the indicator to the platform - 6v dc - 500ma + 230v - 50hz wire the cable attached to the base as shown (if necessary) 4 2 3 1 1 red 2 red 3 red 4 red 1. Red excitation+ 2. ...

  • Page 5

    Indicator and platform assembly rem ove pac k agin g pa ds x2 x2 1 2 3 x4 4 5.

  • Page 6

    Display and keypad on/off units tare t kg/lb kg lb hold low batt ch ac max d = - + sbi 100 zero 0 net zero h old print function keys annunicators tare t tare zero 0 weight is zero on/off zero on/off/zero kg lb unit of measure (flashing led means that the weight reading is not stable.) units kg/lb un...

  • Page 7

    Scale operation turning on and zeroing the scale on/off zero z ero 0 turning off the scale on/off zero selecting unit of measure units kg lb using the tare 1. 2. 3. Net 4. Net removing the tare on/off zero 0 zero kg lb tare net.

  • Page 8

    Hold function with automatic zero on next weigh. 1. Hold print hold 2. 3. 4. Hold hold function with manual release. This function needs to be setup in parameter p3.1 shown on page 10 1. Hold print hold 2. 3. Removing hold hold print hold print function for communications to a printer or pc, the ind...

  • Page 9

    1. 2. Hold print 3. Print user configuration settings setup controls entering setup on/off zero + units selecting parameter tare changing data within the parameter units saving data tare exiting setup on/off zero z ero 0 gross: 45.00kg tare: 1.35kg net: 43.65kg hold print kg moves flashing digit uni...

  • Page 10

    User configuration settings parameter setting default settings in bold p1.Xy auto shutoff timer in minutes set up time for the auto off function. (00 = 0ff, 01-15 = time in minutes) p1.00 p1.01 – p1.15, p1.5 = 15 minutes p2.X hold and print key functionality setup button function 0 = press button on...

  • Page 11

    Rs-232 data commands for sbi protocol the rs232 can be set so a bidirectional connection can be established between the indicator and the host. To establish this connection set parameter p4 to 7, and configure setting p5 (baud) and p6 (parity) to host device. Commands can then be sent from the host ...

  • Page 12

    Other rs-232 output strings p4-1 = output displayed data @ print key : format: p4-2 = output gross, tare, net @ print key format: rs232 serial interface wiring de-9 female scale de-9 male host pin name direction pin name direction 2. Txd out 2. Rxd in 3. Rxd in 3. Txd out 5. Sg - 5. Ground - pins 1,...

  • Page 13

    Scale calibration calibration configuration settings – the scale is configured from the factory to match the specified settings for each unit, as defined by the product specifications and sales brochure. Modification of the setting can be accomplished by altering user configuration settings p7-p10. ...

  • Page 14

    Calibration menu calibration can be done with 25% to 100% of requested load and can be calibrated with 1 or 2 calibration points 1. On/off zero + tare 2. Tare 3 . Tare 4. Enter in calibration weight from 25% to 100% full capacity 25%-100% kg/lb 5. Single point calibration, enter the same weight in a...

  • Page 15

    Service configuration settings the scale is configured from the factory to match the specified settings for each unit, as defined by the product specifications and sales brochure. Modification of the setting can be accomplished by altering user configuration settings p11-p19. Caution: configuration ...

  • Page 16

    Technical specifications scale indicator input signal range: 0mv ~ +30mv sensitivity: >0.2uv/grad internal resolution: approximately 520,000 counts display resolution: can be selected between 500-100,000 system linearity: within 0.01% of fs loadcell excitation voltage: +5 v dc (max current: 85ma) lo...

  • Page 17

    Declarations of compliance united states this equipment has been tested and found to comply with the limits for a class a digital device, pursuant to part 15 of the fcc rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a ...