7. TROUBLE SHOOTING
Treadmill stop suddenly
a. Safety key fall off
Put well the safety key
b. Electronic system problem
Ask for the after sale service
Key defected
Key is damaged.
Change key
Key can not work.
Change key board and wire.
Change pcb board. Change
computer.
E01
Connect wire loose or defected.
Well connect the wire or Change
the wire.
E02
a. Fan or the radiator is in dust.
Clean the dust.
b. The fan is broken lead to the
temperature of the converter in too
high
Change the fan.
c. The converter is broken
Change the converter
E03
The inverter input voltage is
too low
Change the voltage
E05
a. Over the specified load lead to
excessive current protection
Reduce weight
b. Part of treadmill is trapped
adjust the treadmill and restart it
c. the motor is broken if it make noise
or has a burnt smell
Change the motor
d. the converter has a burnt smell
Change the converter
E07
The roller, running board or the running
belt is lack of lubrication
Add some specific oil
E09
a. Poor connection of the seed sensor
connect well the wire or change the
wire.
b. AC motor does not in right
connection
Re-connect the wire of the AC motor
c. Damage of the connection wire
Change the wire
Problem
Posible Cause
Solution
Treadmill does not work
a .
No connected to power supply
Plug into socket
b. Safety switch not insert
Insert safety switch in monitor
c . Cut off the signal circuit system
Check control panel and signal cable
d.
Treadmill is not switch on
Switch on
e.
The fuse is burned out
Change the fuse
Belt does not run properly
a .
Running belt is not well lubricated
Adjust running belt by silicon
b.
Belt is too tight
Adjust running belt
Belt is slipping
a.
Belt is too loose
Adjust running belt
b .
Motor belt is too loose