Salus KL10RF Installation And Wiring Manual - page 2
KL10RF
Installation and Wiring Guide
When using option 2 refer to device
parameters on page xx of the manual.
Fuses
Coordinator
Aerial Connection
Dip Switch Set Up
In order for the wiring centre to be
able to control UFH and Radiators,
there is a need to turn off the UFH
pump for a zone when that zone is
to be used for radiators.
Eg. When fitting a zone for radiators
or towel rail then the Dip Switch for
that zone should be switched to OFF.
The Dip Switches for this are located
under the front lid. When the zone
switch is in the ON position the UFH
pump will run when that zone is
calling for heat along with the boiler.
When it is in the OFF position then
the UFH pump will not run but the
boiler will fire.
There are three other function
switches as well.
Pump & Boiler delay: This gives a
three minute delay to allow
actuators to open before the boiler
fires.
Pump Only Delay: Delays only the
UFH pump from firing for three
minutes.
Actuator NC or NO: This refers to
Normally Open or Normally Closed.
This should be set to NC for
products.
2
Actuator Connections
Actuator connections corresponding to the thermostat connections. Up to 2
cables can be used in each connection (4 Actuators per Zone) If more, that
number needs to be connected, then an external junction box will be needed.
A maximum of xxx actuators can be connected to a zone in this manner.
Optional Cylinder Thermostat: If connecting the cylinder thermostat
directly to the timer then a link needs to be fitted between IN and OUT.
Optional Hot Water Motorised Valve: Used if timed hot water is required.
Optional Overheat Thermostat: Used for connecting a pipe thermostat to
prevent over temperature water damaging sensitive floors. Remove the link
and connect the pipe thermostat so it is Normally Closed. The pipe stat will
open if overheating occurs and
the UFH pump will stop running.
Optional Boiler Enable: This Volt Free connection must come from the boiler
thermostat connection, when any zone calls for heat the Boiler enable will
close causing the boiler to run. If work is being carried out on the boiler then
power to and from the switch will
cease. (Do not connect to the boiler IN terminal by linking a 230V
feed from the wiring centre)
Optional UFH Motorised Valve: If a UFH motorised valve is
fitted then remove the link between OR and GR.
Optional Heat/Cool Changeover: This connection allows heat/cool
changeover of all thermostats using a single external switch (installer supplied).
Switch: Open-Heating Closed-Cooling
Motorised Valves, Pump, Boiler & Stat Connections
This must be carefully removed
or replaced when removing or
replacing the wiring centre
cover, being careful to ensure
the correct orientation.
Ribbon Connection
Thermostat Connections
Thermostat connections are to power the thermostats only, there
is no switched live needed as this is done with a wireless signal.
Power can therefore be supplied to the thermostat locally from
any convenient power source if connecting to the wiring centre
from the thermostat is difficult. Battery powered RF thermostats
can also be used. These can be mixed with 230v RF thermostats or
as an alternative.
A Coordinator will be
needed with all RF
products.
After setting up the coordinator
will assign the wiring centre
number. This is because more than
1 wiring centre may be used on a
project. Pressing the network
button will illuminate the relevant
number. The example shown is for
wiring centre 1, if 1 & 2 are lit it
would be wiring centre 2.
3
4
5
9
6
8
1
Information Display
T
hermostat Z
ones
Groups
1
2
NETWORK
BUTTON
7
www.salus-controls.com Technical Helpline 00000 000000
Option 2
Connect Cylinder
Thermostat to RF
Thermostat for wire
free connection. A
link will be needed
between IN & OUT
as shown by arrow.
IN
HW CYLINDER
THERMOSTAT
HW MOTORISED VALVE
OVERHEAT STAT
UFH PUMP
BOILER ENABLE
UFH MOTORISED VALVE
OUT
IN OUT
IN OUT
BR EA N OR GR
BR EA N OR GR
L N E
ZONE 1
ZONE 2
ZONE 3
ZONE 4
SL N L
SL N L
SL N L
SL N L
SL N L
HW TIMER CONNECTION
THERMOSTAT CONNECTIONS 230V AC
230V AC
Sensor Terminals
Can be used for external AIR, Floor sensor
when configured as thermostat. Can also
be used for cylinder thermostat when
connected for HW.
OPTONAL HOT
WATER
MOTORISED
VALVE
OPTONAL UPH
MOTORISED
VALVE REMOVE
LINK IF USED
Option 1
Connect Cylinder
Thermostat to
wiring centre
IN
HW CYLINDER
THERMOSTAT
HW MOTORISED VALVE
OVERHEAT STAT
UFH PUMP
BOILER ENABLE
UFH MOTORISED VALVE
OUT
IN OUT
IN OUT
BR EA N OR GR
BR EA N OR GR
L N E
ZONE 1
ZONE 2
ZONE 3
ZONE 4
SL N L
SL N L
SL N L
SL N L
SL N L
HW TIMER CONNECTION
THERMOSTAT CONNECTIONS 230V AC
230V AC
OPTONAL HOT
WATER
MOTORISED
VALVE
OPTONAL UPH
MOTORISED
VALVE REMOVE
LINK IF USED
Hot Water Connections
iT600 Wiring Centre KL10RF 004_Layout 1 05/06/2014 15:24 Page 2