Salus SPMV32 Instruction Manual - Three Way Valves
OPERATION
Three way valves
This type of three way motorised valve has ports A (Central
Heating) normally closed with no power to the valve. In this
state water can flow from port AB to Port B if there is demand
for Hot Water only.
When there is a demand for Central Heating, port B will be
closed and water will flow from port AB to A (Central Heating).
When there is demand for Central Heating and Hot Water the
valve will allow flow from AB to A and B.
Plug-in power Lead
The plug in power lead allows easy connection and
disconnection of the electrical supply to the motorised valve
LED Position Indication
To assist installation and diagnostics the SPMV32 comes with
LED position indication. The LED indication is as follows:
• When the Hot Water (HW) is in demand only, no LED’s will
be illuminated.
• When both Central Heating (CH) and Hot water (HW) are in
demand, the two LED’s will be illuminated.
• When Central Heating (CH) is in demand only, one LED will
be illuminated.
SPMV32 INSTRUCTION MANUAL
6
Include if Programmer
has a heating only
selection
CYLINDER STAT
PROGRAMMER
ROOM STAT
COM
CALL
SAT
240V AC 50Hz
supply fuse 1
at 3 A
CALL=STAT CALLING
SAT=STAT SATISFIED
COM=COMMON
COM
CALL
SAT
Mid-position Valve
Typical circuit showing Programmer.
Room ‘Stat and Cylinder’ Stat
as control elements.
L
N
ON
OFF
ON
OFF
H.WATER
HEATING
Yellow
Earth
Blue
Neutral
White
CH call
ORANGE
HW Call
GREY
HW Sat
CH
HW