Samcon ExCam IPP5635 User Manual

Summary of ExCam IPP5635

  • Page 1

    Ex cam ipp5635 user manual.

  • Page 2

    Doc.-id: 160720-pt08ba-ss-excam ipp5635_en_rev.00.Docx, page 2 of 24 content 1 introduction .............................................................................................................. 4 2 technical data .................................................................................

  • Page 3

    Doc.-id: 160720-pt08ba-ss-excam ipp5635_en_rev.00.Docx, page 3 of 24 table of figures table 4.1 – model key ....................................................................................................... 8 figure 5.1 – excam ipp5635 potential equalization .......................................

  • Page 4

    Doc.-id: 160720-pt08ba-ss-excam ipp5635_en_rev.00.Docx, page 4 of 24 1 introduction the excam ipp5635 is a high performance ip dome camera of the latest generation with a 2 megapixel resolution of 1920 x 1080p pixel. It is certified according to atex, iecex, and eac-ex. The dome camera has a continu...

  • Page 5

    Doc.-id: 160720-pt08ba-ss-excam ipp5635_en_rev.00.Docx, page 5 of 24 2 technical data 2.1 parameters of the explosion protection identification marks according to directive 2014/34/eu: ii 2g (zone 1 and 2) ii 2d (zone 21 and 22) explosion protection (gas): ex d iib t6 gb or ex d iib t5 gb explosion ...

  • Page 6

    Doc.-id: 160720-pt08ba-ss-excam ipp5635_en_rev.00.Docx, page 6 of 24 2.3 electrical parameters of the heating (optional) power supply: 12…30 v dc reference power: 24 v dc maximum power input: 40w @-30°c 60w @-50°c suggested fuse supply cable: 6000ma – t at 3g 1.5 mm 2 2.4 system cable skdxx descript...

  • Page 7

    Doc.-id: 160720-pt08ba-ss-excam ipp5635_en_rev.00.Docx, page 7 of 24 2.6 video technical data for details regarding video technical data of the installed axis p5635-e dome camera, please refer to the axis ® product documentation: http://www.Axis.Com/us/en/products/axis-p5635-e 2.7 other technical da...

  • Page 8

    Doc.-id: 160720-pt08ba-ss-excam ipp5635_en_rev.00.Docx, page 8 of 24 3 safety guidelines please observe the safety guidelines indicated in the ex installation manual of the t08 excam series! 4 illustration of the model key the following model options are currently available for the excam ipp5635: mo...

  • Page 9

    Doc.-id: 160720-pt08ba-ss-excam ipp5635_en_rev.00.Docx, page 9 of 24 6) k = terminal block execution (standard) skdxx: 8 x single pin twisted pair (solid conductor 0.64 mm 2 , about 5 mm stripped), 1x shield (cu braid 2.5 mm 2 , ferules) supply: („Ölflex 440p2 x 2.5 mm2 cu litz wire with ferule, she...

  • Page 10

    Doc.-id: 160720-pt08ba-ss-excam ipp5635_en_rev.00.Docx, page 10 of 24 5 commissioning attention! Please observe the national regulations regarding security, installa- tion, and accident prevention (e.G. Din en 60079-14) as well as the safety guidelines described in this user manual and the ex instal...

  • Page 11

    Doc.-id: 160720-pt08ba-ss-excam ipp5635_en_rev.00.Docx, page 11 of 24 the excam ® ipp5635 is delivered with an electrical connection cable type skdxx (sys- tem kabel d igital) and optional with an additional supply cable e.G. Of the type „Ölflex® 440p “. The maximum cable length is 100 m (depending ...

  • Page 12

    Doc.-id: 160720-pt08ba-ss-excam ipp5635_en_rev.00.Docx, page 12 of 24 5.2.2 connection and protection figure 5.2 – excam ipp5635 t08-tnxcd-b-xxx-k-n figure 5.3 – excam ipp5635 t08-tnxcd-b-xxx-p-n.

  • Page 13

    Doc.-id: 160720-pt08ba-ss-excam ipp5635_en_rev.00.Docx, page 13 of 24 figure 5.4 – excam ipp5635 t08-tnxcd-b-xxx-k-l(l) figure 5.5 – excam ipp5635 t08-tnxcd-b-xxx-p-l(l).

  • Page 14

    Doc.-id: 160720-pt08ba-ss-excam ipp5635_en_rev.00.Docx, page 14 of 24 the green patch cable skdxx disposes of 8(+1) conductors used for the data transfer with other network devices as well as to power the camera. In order to guarantee the power supply (power device, pd) of the excam ipp5635 (power d...

  • Page 15

    Doc.-id: 160720-pt08ba-ss-excam ipp5635_en_rev.00.Docx, page 15 of 24 table 5.2 – pin assignment skdxx and plug contact rj45 figure 5.6 – rj45 contact assignment particularly in emc critical environments, it is important to earth the shield at the terminal block side (q.V. Figure 5.3 – pin with blac...

  • Page 16

    Doc.-id: 160720-pt08ba-ss-excam ipp5635_en_rev.00.Docx, page 16 of 24 if the ex cctv application calls for a separate 48 v dc supply voltage, the wire/pin as- signment has to reflect mode b operation mode (q.V. Table 5.2)! If the camera is equipped with a heating (type l or type ll), a second power ...

  • Page 17

    Doc.-id: 160720-pt08ba-ss-excam ipp5635_en_rev.00.Docx, page 17 of 24 5.3 optional steps 5.3.1 work preparation attention! Please carry out any preoperational work carefully and in accordance with the applicable regulations attention: note: depending on the zone classification, it might be necessary...

  • Page 18

    Doc.-id: 160720-pt08ba-ss-excam ipp5635_en_rev.00.Docx, page 18 of 24 5.3.2 opening the pressure-resistant housing the opening of the tnxcd housing requires special tools and it is not intended that cus- tomer open the housing. In case that due to an unforeseeable event the housing has to be opened,...

  • Page 19

    Doc.-id: 160720-pt08ba-ss-excam ipp5635_en_rev.00.Docx, page 19 of 24 6 network access and visualization in the following, the most important steps for the initial commissioning of the camera are described. The configuration menu of the web surface allows an intuitive navigation and offers several c...

  • Page 20

    Doc.-id: 160720-pt08ba-ss-excam ipp5635_en_rev.00.Docx, page 20 of 24 the “axis ip utility“ tool automatically recognizes all excam devices and displays them. It can also be used to manually assign a static ip address. Please note that the excam ipp5635 network camera has to be installed within the ...

  • Page 21

    Doc.-id: 160720-pt08ba-ss-excam ipp5635_en_rev.00.Docx, page 21 of 24 7 maintenance / servicing / alterations the national regulations concerning the maintenance and servicing of electrical devices within hazardous areas are to be observed. The required maintenance intervals are specific to the indi...

  • Page 22

    Doc.-id: 160720-pt08ba-ss-excam ipp5635_en_rev.00.Docx, page 22 of 24 10 drawings & 3d models all drawings, 3d models, certificate and more is available in the download area of the product page on our homepage: http://www.Samcon.Eu/en/products/network/excam-ipp5635/ in case of missing technical info...

  • Page 23

    Doc.-id: 160720-pt08ba-ss-excam ipp5635_en_rev.00.Docx, page 23 of 24 11 notes.

  • Page 24

    Doc.-id: 160720-pt08ba-ss-excam ipp5635_en_rev.00.Docx, page 24 of 24 schillerstrasse 17, 35102 lohra-altenvers www.Samcon.Eu, info@samcon.Eu fon: +49 6426 9231-0, fax: - 31.