Samlex Europe SEC - 1215E Owner's Manual

Summary of SEC - 1215E

  • Page 1

    Www.Samlex.Com www.Samlex-solar.Com sec - 1215e sec - 1230e sec - 2415e model no. Automatic battery charger owner’s manual please read this manual before operating your charger.

  • Page 2

    Contents important safety precautions ................................................. 2 description and features .......................................................... 3 charging stages ................................................................................ 4 protections ................

  • Page 3

    Important safety precautions hazardous conditions may result if the charger is not installed or operated correctly. Please read the following instructions to prevent personali njury or damage to the charger: batteryrelated r to reduce the risk of battery explosion, follow these instructions and thos...

  • Page 4: Description

    Description these chargers are used to charge lead acid batteries (fle ece/agm/gel/wet). Sec-1215e (maximum charging current 15a) and sec-1230e ( maximum charging current 30a) are used to charge 12vbatteries. Sec-2415e (maximum charging current 15a) is used to charge 24v batteries. These chargers ca...

  • Page 5: Charging Stages

    Charging stages note ! - voltage readings on no load the output has one common negative terminal and three positive terminals for charging 3 banks of batteries. Each positive terminal has an internal isolating diode in series which has a forward voltage drop of 0.8 to1.1v. On no load (that is when n...

  • Page 6: Caution!

    Caution! 3 stage charging is recommended for charging stand-alone unloaded batteries(there is no load connected to the battery when it is being charged). If a load is also connected simultaneously, a part of the charger‘s output current will be diverted to this load. Thus, the charger may remain loc...

  • Page 7: Installation

    Installation location, mounting and safety the charger is required to be installed in a safe, well ventilated and dry location. Please see the details given under “important safety instructions“ on page 2. With the help of 4 screws, mount the charger on a vertical bulkhead with the output terminal s...

  • Page 8

    Preparing the charger for operation selecting the type of battery and charging stages the float voltage and boost voltage (also called absorption or overcharge voltage) of different types of lead acid batteries are different. Also, when a charger is used to charge a battery and simultaneously supply...

  • Page 9

    Connecting the batteries or other dc loads the output has a common negative(-) terminal and 3 positive terminals for connection of 3 banks of batteries. Each positive connector has it‘s own internal isolating diode which works as a battery isolator. If more than one bank of batteries is connected, t...

  • Page 10: Operation

    Operation when the charger is switched on, the red led lights up indicating that output voltage is available. When the batteries are being charged or when the charger is supplying other dc load, the current fed by the charger will be indicated by the ammeter. When the batteries are discharged, they ...

  • Page 11

    Charging more than one bank of batteries caution! When charging more than one bank of batteries at the same time using 3 stage charging, ensure that the batteries in the banks are in a similar discharged condition.If one bank is completely discharged and another is almost fully charged, the bank tha...

  • Page 12: Troubleshooting

    Troubleshooting symptoms when the charger is powered and connected to the battery the red led is off the dc side fuse may have blown due to wrong polarity of battery connection. Ensure positive of the battery is connected to the positive of the charger and the negative of the battery is connected to...

  • Page 13: Internal Fuse Ratings

    Symptoms when the charger is powered and is being used as a dc power supply/ups the voltage drops when load is switched on the load is trying to draw current more than the current limit value of the charger (the current limit value is the maximum specified charging amps). Once the load current reach...

  • Page 14

    Sec-1215e sec-1230e sec-2415e nominalinputvoltage 230 vac,50 hz 230 vac, 50 hz 230 vac, 50 hz (pre-set) output voltage, boost 1,2 14.4 vdc, 14.4 vdc, 28.8 vdc or 14.8 vdc or 14.8 vdc or 29.6 vdc or disabled or disabled or disabled output voltage, float 1 13.8 vdc 13.8 vdc 27.6 vdc output amps 15 a 3...

  • Page 15

    2 year limited warranty the automatic battery charger manufactured by samlex europe b.V. ( the “ warrantor “ ) is warranted to be free from defects in workmanship and materials under normal use and service. This warranty is in effect for 2 years from the date of purchase by the user ( the “ purchase...

  • Page 16: Sec - 1215E

    Www.Samlex.Com www.Samlex-solar.Com sec - 1215e sec - 1230e sec - 2415e model no. Automatic battery charger owner’s manual please read this manual before operating your charger.