TROUBLESHOOTING GUIDE
PROBLEM: Low or No Output Voltage
REASON
POSSIBLE SOLUTION
Capacity of the battery is inadequate.
Use higher capacity battery.
Poor contact with battery terminals.
Clean terminals thoroughly.
Automatic Shutdown due to battery
Recharge or replace battery.
voltage below 20 volts.
Automatic Shutdown as equipment being
Use a higher capacity inverter
operated draws too much power.
or do not use this equipment.
Red overload LED lights.
Automatic Shutdown as the inverter is too hot.
Allow inverter to cool.
Check for adequate ventilation.
Reduce the load on the inverter
to rated continuous power output.
Using incorrect type of voltmeter.
Use true RMS reading meter
See Page 12 “Technical Information" .
Automatic Shutdown due to input voltage
beyond 30V
(this may permanently damage the inverter).
Charging alternator's voltage has been set
Set the voltage correctly or repair.
beyond 30V, or its regulator has become
defective.
Batteries are being charged simultaneously
Disconnect unregulated solar panel
from an unregulated solar panel or a
when using the inverter or set
regulated solar panel set beyond 30V
voltage of regulated solar panel to less
than 30V.
Battery charger connected to the batteries
Disconnect the battery charger when
with its boost voltage higher than 30V.
using the inverter or ensure its boost
voltage is less than 30V.
Polarity of input connection was reversed.
None. Will cause permanent damage.
Page 16