Samlexpower PST-12S-12A Owner's Manual - Section 3 |
6 | SAMLEX AMERICA INC.
SAMLEX AMERICA INC. | 7
LED StatuS INDICatOR
INvERtER & uSB StatuS
LED is OFF
AC output is available: No USB power
No AC output: 15A input side fuse is blown
GREEN
USB normal
ORANGE
Inverter shut down
due to:
- Over temperature
- Low DC input voltage
- High DC input voltage
USB normal
RED
No USB power
Section 3 |
operation Guidelines
High DC Input voltage
- The unit will shut down if DC input voltage > 16.5 VDC.
- The LED Status Indicator (2, Fig. 1) turns ORANGE.
- The unit will reset automatically when voltage is < 16.5 VDC.
Over voltage On uSB Port
- USB output is shut down if USB output > 6.2 VDC.
- The LED Status Indicator (2, Fig. 1) will be OFF or RED.
Operational conditions indicated by the LED Status Indicator (2, Fig. 1) are given in the
following table:
Cooling
- The inverter has a temperature controlled fan for cooling.
- The fan will start once the temperature of the hot spot inside the unit exceeds 70°C.
The fan may not be running all the time.
- Place the unit in a cool, well ventilated space that has adequate cool replacement
air (Fig. 4).