Samlexpower PST-60S-24A Owner's Manual - page 7
Other manuals for PST-60S-24A:
Owner's Manual, Owner's Manual
Manual is about: DC-AC Inverters
of
16
Page 7
INSTALLATION & MAKING CONNECTIONS
1
115V AC output receptacles
2
Power on/off Switch
3
Green L.E.D. - Power output status
4
Red L.E.D. - Overload
5
Red L.E.D. - Over temperature
6
Input terminals
(back of unit -not shown)
RED - Positive (+)
WHITE - Negative (-)
7
Cooling fan
(back of unit - not shown)
8
Grounding lug
(back of unit - not shown)
CAUTION!
Reverse polarity of input connection will blow the fuse inside the
inverter and may cause permanent damage. Please ensure that
the RED positive terminal is connected to the positive(+)
terminal of the battery and the WHITE negative (-) terminal is
connected to the negative (-) terminal of the battery. Damage
due to reverse polarity is not covered by warranty.
2
1
3
4
5