Inverter parameter
Sam-100-12
Input
bATTerY SYSTeM VoLTAGe
12 VDC
NOMINALINPUTVOLTAGE
13.8 VDC
INPUTVOLTAGERANGE
10.8 VDC to 15.4 VDC
NOLOADCURRENT
0.3A ± 0.1A
output
OUTPUTVOLTAGEWAVEFORM
Modified Sine Wave
OUTPUTVOLTAGE
115VAC+10%/-2%
OUTPUTFREQUENCY
60Hz±5%
OUTPUTPOWER,CONTINUOUS(RESISTIVELOAD)
100W
OUTPUTPOWER,SURGE(<1SEC.,RESISTIVELOAD)
200W
PEAKEFFICIENCY(AT50%OFCONTINUOUSPOWER) 90%
USBCHARGINGPORT
USB3.0,ConnectorType"A":5VDC,2.1A
protectIonS
LOWINPUTVOLTAGESHUTDOWN
10.5 VDC.± 0.3VDC. Auto reset at
11.5 VDC. ± 0.3VDC
HIGHINPUTVOLTAGESHUTDOWN
15.4 VDC.± 0.2VDC. Auto reset at
15.0 VDC.± 0.2VDC
OVERLOADANDGROUND
FAULTSHUTDOWN
Yes. Latches in shutdown condition. Manual
reset: remove the inverter from the 12V
Power outlet. Wait for 3 min and re-insert
firmly.
OVERTEMPERATURESHUTDOWN
Yes. Auto reset on cooling down.
CooLING fAN
1 - Always oN.
INPUTFUSE:INSIDETOPOFTHE12VPOWER
PLUGPORTION
10A, 250V (fast Acting, Type AGC-10;
Dimensions:0.25"x1.25")
connectIonS
DCINPUTCONNECTION
12 V Power Plug (Cigar Plug)
ACOUTPUTCONNECTION
one NeMA5-15r outlet
monItorInG
STATUSINDICATION
GREENLED:ON-NORMAL;OFF-SHUT
DoWN
GeneraL
OPERATINGTEMPERATURERANGE
0°Cto25°C/32°Fto77°Fat100%loading;
26°Cto35°C/78.8°Fto95°Fat80%loading
OPERATINGHUMIDITY
<80%;Non-condensing