Sampford IXL Cannon User Instructions - page 2
Page 18.
Initial Start-up 1
Quick start guide. 2
Safety warnings 3
Features 4
Thermostat LCD 5
Functions 6-7
Button functions
Programming button functions
Initial setup 8
On / Off
Time and day of the week
Manual mode 9
Automatic mode 9
Programming 10-11
Programming screen displays 12
Program mode 13
Factory default settings
Your settings
Settings 14
Change between C° and F°
Restore factory default settings
Teaching the thermostat ID code
to the control unit
Frequently asked questions 15
Quick reference table 16
Back Up Switch 17
Service 18
Battery type: 2 X AA batteries
Battery life : approximately 12 months
Transmission frequency: 433.92 Mhz
Dimensions: 140MM x 80mm x 20mm
Page 1.
NOTES
CONTENTS
INITIAL START-UP
1. Disconnect heater from power supply.
2. Fitted batteries to remote thermostat unit.
3.connect Heater back to power supply and point
Remote Thermostat at heater. Within 15 seconds press
Sequence of “p,t,t,up” on R
emote Thermostat
If correctly done, a display of “lc” will appear on display.
Unit will now operate via Remote Thermostat.
For further details see page 14 settings
- Teaching RF Thermostat ID code to Control unit