Samson 15 PW Owner's Manual

Summary of 15 PW

  • Page 1

    Owner’s manual wood stove with a water jacket samson 15 pw.

  • Page 2

    Dimension and technical specification for samson 15 pw unit external dimensions: height: 730 mm width: 730 mm depth: 450 mm weight 194 kg flue outlet: flue pipe diameter dn 160 1-connector pipe 1” – male thread 1” nominal power 7,5 kw water jacket capacity 10 l introduction thank you for choosing sa...

  • Page 3

    Installation guide the stove must be installed in compliance with the provisions of relevant local binding regulations. Pn-en 13229:2002 norm “inserts and open fireplaces for solid fuels. Requirements and testing”, pn-en 13240:2002 norm “heaters for solid fuels. Requirements and testing” is saying: ...

  • Page 4

    Pipe dn28 must be used to connect the water jacket to the system. The application of smaller diameter pipes is prohibited. The water system must be equipped with a water overflow tank in compliance with the binding regulations (see: figure below) installation diagram for samson 15 pw specification 1...

  • Page 5

    Water level. You must not establish a fire in the stove before filling up the water jacket with water. Establishing a fire without filling up the system with water will void the guarantee. The stove casing must provide access to the hydraulic fittings of the water jacket through clean-up doors. It i...

  • Page 6

    Fuel our products are designed exclusively for burning wood such as: oak, hornbeam, ash, beech, etc. The most suitable wood should be seasoned as chopped logs for at least a year in a dry and well-aerated place. Wood from coniferous trees is not recommended because it ignites too rapidly. Furthermor...

  • Page 7

    Chimney system inspection chimney system inspections should be documented in the form enclosed herein. Before commissioning for use, any modification or changes to the flue liner, the chimney system should be inspected by a qualified chimney inspector. Chimney duct inspection should be conducted by ...

  • Page 8

    Ash removal ashes should be regularly removed to prevent ash spills outside and the build-up of ash around the start-up air housing located inside the firebox. Ashes should be placed in a metal container with a tight fitting lid. Always leave a thin layer of ash in the bottom of the firebox for prot...