Samsung AC340B Owner's Instructions Manual

Summary of AC340B

  • Page 1

    Air cleaner e db98-13335a(1) owner’s instructions ac340b ac340br ac340bg.

  • Page 2: Safety Precautions

    E- 2 safety precautions the following safety precautions must be taken into account when using this product. ◆ do not install this product in places where it will come into contact with combustible gases such as sulfuric gas, hydrogen gas, methane gas, etc. ◆ do not install this product in places th...

  • Page 3: Contents

    E- 3 contents ◆ p reparing the a ir c leaner ■ safety precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 ■ view of the unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 ■ getting started . . . . . . . . . . . . . . . . . . . . . ....

  • Page 4: View of The Unit

    E- 4 view of the unit control panel odor sensor dust sensor air outlet air flow blade filter box front panel power plug pre-filter ionizer electrostatic filter nano silver formula tio2 photocatalyst filter anion generator anti-bacterial fan metal filter washable filter section recovery filter sectio...

  • Page 5

    E- 5 indicator anion indicator filter reset button & indicator anion button clean level indicator operating mode indicator contamination level indicator ◆ contamination level indicator - classifies the various contaminants in the indoor air, as odor, mote and dust, and up to 5 levels can be displaye...

  • Page 6: Etting Started

    G etting started you have just purchased an air cleaner and it has to be installed according to the safety precautions of page 2. This manual contains important information concerning the use of your air cleaner. Please take some time to read this booklet as it will help you take full advantage of t...

  • Page 7

    Selecting the automatic mode in the automatic mode, the air cleaner automatically adjusts the clean level according to the signal of the more contaminated level after comparing the dusts and motes contamination level with the odor contamination level in the indoor air. Anions are generated into an a...

  • Page 8: Selecting The Pollen Mode

    Selecting the pollen mode e- 8 the pollen mode can eliminate pollen and dust particles effectively in the indoor air. In this operating mode, the air cleaner automatically adjusts the clean level according to the dusts or motes contamination level without the odor contamination level in the indoor a...

  • Page 9: Selecting The Sleep Mode

    Selecting the sleep mode e- 9 if you wish the air cleaner to clean the air in your room quietly, select the sleep mode. In this operating mode, the air cleaner runs in "low speed" which is the quietest clean level setting. Anions are generated into an air automatically and the air flow blade does no...

  • Page 10: Selecting The Odor Mode

    Selecting the odor mode if you select the odor mode, the air cleaner can eliminate airborne contaminants and harmful smells effectively in the indoor air. In this operating mode, the air cleaner automatically adjusts the clean level according to the signal of the odor contamination level without the...

  • Page 11: Generating Anions

    Generating anions e- 11 the anion generator generates anions, which are beneficial to the human body. Use this function if you want to feel refreshed both physically and mentally, just as if you were in the midst of a forest. If the air cleaner is turned on, anions are generated automatically. 1 if ...

  • Page 12

    Adjusting the clean level (fan speed) the air cleaner automatically adjusts the clean level according to the contamination levels of the indoor air. It is also possible for you to manually select the clean level. 1 if you wish to manually select the clean level, press the button one or more times un...

  • Page 13: Operating Recommendations

    Operating recommendations e- 13 here are a few recommendations that you should follow when using your air cleaner. Topic recommendation wash indicator if the light on the "wash" indicator comes on, the washable filters must be cleaned. The washable filters must be cleaned more often in environments ...

  • Page 14: Cleaning The Air Cleaner

    Cleaning the air cleaner e- 14 cleaning the lens of the dust sensor to get the best possible result from your air cleaner, you must clean the lens of the dust sensor regularly. The dust sensor is responsible for sensing the accumulation level of small and big dust particles in the air in your room. ...

  • Page 15

    E- 15 3 leave the washable filter section in the shade to dry for over 12 hours. 5 press the control panel’s button for 2 seconds. Result: ◆ the wash indicator on the control panel turns off. It will light up again when the time for the next filter washing comes. ◆ the air cleaner beeps. 4 put the w...

  • Page 16

    Cleaning the air cleaner (cont.) e- 16 3 after pushing the recovery filter section back into the place, close the filter box. Recovering the photocatalyst filter the phototcatalyst filter eliminates various odors in the indoor air. 1 open the filter box and pull out the recovery filter section towar...

  • Page 17: Solving Common Problems

    E- 17 solving common problems explanation/solution ◆ check for a power failure. ◆ check that the power plug is plugged in tightly. ◆ check that the power outlet is not of a poor quality. ◆ check that the filter box is closed properly. Problem the air cleaner does not operate. Before contacting the a...

  • Page 18: Technical Specifications

    Technical specifications e- 18 model ac340b ac340br ac340bg 220-240v~, 50/60hz power supply.

  • Page 19: Memo

    E- 19 memo.

  • Page 20

    Electronics printed in korea this air cleaner is manufactured by:.