Samsung AC401B Owner's Instructions Manual

Summary of AC401B

  • Page 1

    Air cleaner e db98-13331a(1) owner’s instructions ac401b ac401br ac401bg.

  • Page 2: Safety Precautions

    E- 2 safety precautions the following safety precautions must be taken into account when using this product. ◆ do not install this product in places where it will come into contact with combustible gases such as sulfuric gas, hydrogen gas, methane gas, etc. ◆ do not install this product in places th...

  • Page 3: Contents

    E- 3 contents ◆ p reparing the a ir c leaner ■ safety precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 ■ view of the unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 ■ remote control-buttons . . . . . . . . . . . . . . . . . . ...

  • Page 4: View of The Unit

    E- 4 view of the unit control panel odor sensor dust sensor remote control case air outlet air flow direction blade filter box front panel power plug pre-filter ionizer electrostatic filter nano silver formula hepa filter vocs filter tio2 photocatalyst filter anion generator anti-bacterial fan metal...

  • Page 5

    E- 5 indicator anion indicator filter reset button & indicator anion button remote control sensor clean level indicator operating mode indicator contamination level indicator ◆ indicator - displays the clean level by differing its blinking speed. - if the air cleaner is operating at the pollen mode,...

  • Page 6: Remote Control - Buttons

    Remote control - buttons e- 6 power button air flow blade swing button dimmer button clean level selection button operating mode selection button anion button.

  • Page 7: Etting Started

    G etting started you have just purchased an air cleaner and it has to be installed according to the safety precautions of page 2. This manual contains important information concerning the use of your air cleaner. Please take some time to read this booklet as it will help you take full advantage of t...

  • Page 8: Keeping The Remote Control

    Inserting the battery into the remote control ◆ always direct the remote control towards the remote control sensor on the air cleaner when operating it from a distance. ◆ when you press a button on the remote control and the air cleaner makes a ringing sound, it means the function has been chosen. ◆...

  • Page 9

    This chapter indicates how to operate your air cleaner with the buttons on the control panel. U u u u s s s s ii ii n n n n g g g g tt tt h h h h ee ee c c c c o o o o n n n n tt tt r r r r o o o o ll ll p p p p a a a a n n n n ee ee ll ll e- 9.

  • Page 10

    Selecting the automatic mode e- 10 in the automatic mode, the air cleaner automatically adjusts the clean level according to the signal of the more contaminated level after comparing the dusts and motes contamination level with the odor contamination level in the indoor air. Anions are generated int...

  • Page 11: Selecting The Pollen Mode

    Selecting the pollen mode e- 11 the pollen mode can eliminate pollen and dust particles effectively in the indoor air. In this operating mode, the air cleaner automatically adjusts the clean level according to the dusts or motes contamination level without the odor contamination level in the indoor ...

  • Page 12: Selecting The Sleep Mode

    Selecting the sleep mode if you wish the air cleaner to clean the air in your room quietly, select the sleep mode. In this operating mode, the air cleaner runs in "low speed" which is the quietest clean level setting. Anions are generated into an air automatically and the air flow blade does not mov...

  • Page 13: Selecting The Odor Mode

    Selecting the odor mode if you select the odor mode, the air cleaner can eliminate airborne contaminants and harmful smells effectively in the indoor air. In this operating mode, the air cleaner automatically adjusts the clean level according to the signal of the odor contamination level without the...

  • Page 14: Generating Anions

    Generating anions the anion generator generates anions, which are beneficial to the human body. Use this function if you want to feel refreshed both physically and mentally, just as if you were in the midst of a forest. If the air cleaner is turned on, anions are generated automatically. 1 if the an...

  • Page 15

    Adjusting the clean level (fan speed) the air cleaner automatically adjusts the clean level according to the contamination levels of the indoor air. It is also possible for you to manually select the clean level. 1 if you wish to manually select the clean level, press the button one or more times un...

  • Page 16

    This chapter indicates how to operate your air cleaner with a remote control. U u u u s s s s ii ii n n n n g g g g tt tt h h h h ee ee r r r r ee ee m m m m o o o o tt tt ee ee c c c c o o o o n n n n tt tt r r r r o o o o ll ll e- 16.

  • Page 17

    Adjusting the air flow direction the movement of the air flow blade changes according to the operating modes. The air flow blade swings automatically in the pollen and odor mode, but it is fixed in one position in the auto and sleep mode. The air flow blade can only be controlled with the remote con...

  • Page 18

    Adjusting the display brightness 1 select the brightness level of the display by pressing the button on the remote control one or more times until the desired brightness is displayed. There are three brightness levels that you can choose from: - press the button once: the display becomes dim. - pres...

  • Page 19

    Adjusting the clean level (fan speed) 1 if you wish to manually select the clean level, press the button one or more times until the desired clean level is selected. Result: ◆ the air cleaner beeps. ◆ the air cleaner operates in the clean level that was selected. 2 if necessary, press the (power) bu...

  • Page 20: Selecting The Operating Mode

    Selecting the operating mode 1 if the desired operating mode is not displayed on the display, select an operating mode by pressing the button on the remote control until it is displayed on the display. Result: ◆ the air cleaner beeps. ◆ the air cleaner operates in the desired operating mode. 2 if ne...

  • Page 21: Generating Anions

    Generating anions 1 if the anion indicator is not displayed on the display, select the anion generation function by pressing the button on the remote control. Result: ◆ the air cleaner beeps. ◆ the anion indicator lights up on the display. ◆ the air cleaner generates anions into the indoor air. 2 if...

  • Page 22: Operating Recommendations

    Operating recommendations here are a few recommendations that you should follow when using your air cleaner. Topic recommendation wash indicator if the light on the "wash" indicator comes on, the washable filters must be cleaned. The washable filters must be cleaned more often in environments that i...

  • Page 23: Cleaning The Air Cleaner

    Cleaning the air cleaner e- 23 cleaning the lens of the dust sensor to get the best possible result from your air cleaner, you must clean the lens of the dust sensor regularly. The dust sensor is responsible for sensing the accumulation level of small and big dust particles in the air in your room. ...

  • Page 24

    Cleaning the air cleaner (cont.) e- 24 3 leave the washable filter section in the shade to dry for over 12 hours. 5 press the control panel’s button for 2 seconds. Result: ◆ the wash indicator on the control panel turns off. It will light up again when the time for the next filter washing comes. ◆ t...

  • Page 25

    E- 25 3 replace the old hepa filter with new one, and place it back into the replacement filter section. 5 press the control panel’s button for 2 seconds. Result: ◆ the replace indicator on the control panel turns off. It will light up again when the time for the next filter replacement comes. ◆ the...

  • Page 26: Solving Common Problems

    Solving common problems e- 26 explanation/solution ◆ check for a power failure. ◆ check that the power plug is plugged in tightly. ◆ check that the power outlet is not of a poor quality. ◆ check that the filter box is closed properly. Problem the air cleaner does not operate. Before contacting the a...

  • Page 27: Technical Specifications

    Technical specifications e- 27 model ac401b ac401br ac401bg 220-240v~, 50/60hz power supply.

  • Page 28

    Electronics printed in korea this air cleaner is manufactured by:.