Summary of AS07A5MA

  • Page 1

    English owner’s instructions & installation manual manual de instrucciones & manual de instalaciÓn manuel d’utilisation & manuel d’installation ductless mini - split (cool) endidura - mini endÓcrino (refrigeración) sans conduit mini - sÉparÉ (refroidissement) e s f db68-01822a(3) esp aÑol franÇais a...

  • Page 2

    Safety precautions the following safety precautions must be taken when using your air conditioner. 1 make sure that the indoor unit is correctly ventilated at all times; do not place clothing or other materials over it. 2 never spill liquid of any kind into the indoor unit. Should this happen, switc...

  • Page 3: Contents

    Contents ◆ p reparing your air conditioner ■ safety precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 ■ view of the unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 ■ remote control-buttons and display . . . . . . . . . . . . . . . . . ...

  • Page 4

    View of the unit the design and shape are subject to change according to the model. Indoor unit air filter (under the grille) air flow blades (outlet) air inlet timer indicator standard indicator nature indicator power indicator silence indicator remote control sensor saving indicator on/off & 5 way...

  • Page 5

    Air inlet(rear) air outlet connection valve us07a5(a6)ma us09a5(a6)ma outdoor unit air inlet(rear) air outlet connection valve (inside) us12a5(a6)mc outdoor unit air inlet(rear) air outlet connection valve us18a5(a6)rc us24a1(a2)rc outdoor unit e- 5 english.

  • Page 6

    Remote control - buttons and display operating mode ( auto, cool, dry, fan) remote control transmission indicator mode selection button (auto, cool, dry, fan) turbo/sleep mode selection button swing button on timer button off timer button on/off & timer set/cancel button fan speed adjustment button ...

  • Page 7: Etting Started

    G etting started you have just purchased a split type air conditioner and it has been installed by your installation specialist. Your owner’s instructions contain much valuable information on using your air conditioner. Please take the time to read them as they will help you take full advantage of t...

  • Page 8

    Inserting the remote control batteries push the battery cover on the rear of the remote control with your thumb in the direction of the arrow and remove it. Insert the two batteries, taking care to respect the polarities : ◆ + on the battery with + on the remote control. ◆ - on the battery with - on...

  • Page 9

    5 way function press the (on/off) button one or more times until the desired mode is selected. 1 to stop the operating, press the (on/off) button until all indicators turn off. 2 you can select the 5 way function with operating mode of the air conditioner for more comfortable circumstances. You can ...

  • Page 10

    Selecting the automatic operating mode you can start the air conditioner in automatic mode from your remote control. In the automatic mode, the standard temperature and the optimum fan speed is selected automatically. You can adjust the standard temperature but not the fan speed. 1 if the is not dis...

  • Page 11

    Cooling your room 1 if necessary, press the (on/off) button. Result: ◆ the 5 way indicator on the indoor unit comes on. ◆ the air conditioner starts up in the mode selected when the unit was last used. ◆ the indoor unit beeps. The air conditioner is fitted with a protection mechanism to prevent the ...

  • Page 12

    Changing the room temperature quickly the turbo cooling function is used to cool your room as quickly as possible. E e e e x x x x a a a a m m m m p p p p ll ll e e e e : you have just come home and find that the room is very hot. You wish to cool it down as quickly as possible. The turbo function o...

  • Page 13

    Removing excess humidity e- 13 english if the atmosphere in your room is very humid or damp, you can remove excess humidity without lowering the room temperature too much. 1 if necessary, press the (on/off) button. Result: ◆ the 5 way indicator on the indoor unit comes on. ◆ the air conditioner star...

  • Page 14

    Airing your room if the atmosphere in your room is stale, you can air the room using the fan feature. 1 if necessary, press the (on/off) button. Result: ◆ the 5 way indicator on the indoor unit comes on. ◆ the air conditioner starts up in the mode selected when the unit was last used. ◆ the indoor u...

  • Page 15

    Adjusting the air flow direction vertically e- 15 english depending on the position of the indoor unit on the wall of your room, you can adjust the position of the outer air flow blade on the bottom of the unit, thus increasing the efficiency of the air conditioner. 1 press the swing button one or m...

  • Page 16

    Setting the on timer if you want to turn on the air conditioner before the timer reaches the setting time, press the (on/off) button. N n n n o o o o tt tt e e e e the on timer enables you to switch on the air conditioner automatically after a given period of time. You can set the period of time fro...

  • Page 17

    Setting the off timer the off timer enables you to switch off the air conditioner automatically after a given period of time. You can set the period of time from 30 minutes to 24 hours. To set the operating time, press the off timer button one or more times until the required time is displayed. Poss...

  • Page 18

    Setting the sleep timer the sleep timer can be used when you are cooling your room to switch the air conditioner off automatically after a period of six hours. N n n n o o o o tt tt e e e e if you wish to switch the unit off at a specific time, refer to page 17. 1 make sure that you have selected ei...

  • Page 19

    Operating recommendations here are a few recommendations that you should follow when using your air conditioner. Topic recommendation power failure if a power failure occurs when the air conditioner is operating, the unit is switched off. When the power returns, ✴✴ a2 ✴✴ ✴✴ a6 ✴✴ ✴✴ a1 ✴✴ ✴✴ a5 ✴✴ y...

  • Page 20

    Temperature and humidity ranges the following table indicates the temperature and humidity ranges within which the air conditioner can be used. If the air conditioner is used at... Then... High temperatures the automatic protection feature may be triggered and the air conditioner stopped. Low temper...

  • Page 21

    Cleaning your air conditioner e- 21 english to get the best possible use out of your air conditioner, you must clean it regularly to remove the dust that accumulates on the air filter. Before cleaning your air conditioner, ensure that you have switched off the breaker used for the unit. 1 open the f...

  • Page 22

    Solving common problems e- 22 explanation/solution ◆ check that the breaker used for the air conditioner is switched on. ◆ check that the 5 way indicator on the indoor unit is on; if necessary press the (on/off) button on the remote control. ◆ check whether the timer indicator on the indoor unit is ...

  • Page 23

    Installing a filter (option) e- 23 english 3 open the front grille by pulling on the tabs on the lower right and left sides of the indoor unit. 2 insert the filter in the filter holder and press the three insert tabs until you hear a click. 1 remove the vinyl packing from the filter. N n n n o o o o...

  • Page 24

    Technical specifications e- 24 model indoor unit outdoor unit as07 ✴✴ ma as09 ✴✴ ma as12 ✴✴ ma performance ratings capacity cooling seer moisture removal air flow(cooling, high) sound rating-outdoor power source min.Ampacity cooling watts connections liquid line o. D. Suction line o.D. Factory pre-c...

  • Page 25

    E- 25 english model indoor unit outdoor unit as18 ✴✴ rc as24 ✴✴ rc performance ratings capacity cooling seer moisture removal air flow(cooling, high) sound rating-outdoor btu/h pts/h cfm db 17500 10.0 477 55 23500 10.0 477 59 electrical data power source min.Ampacity cooling watts a w refrigeration ...

  • Page 26: Nstallation

    E- 26 i nstallation m anual.

  • Page 27: Contents

    E- 27 english contents ◆ p reparing the i nstallation ■ deciding on where to install the air conditioner . . . . . . . . . . . 28 ■ air conditioner and accessories . . . . . . . . . . . . . . . . . . . . . . . 30 ◆ i nstalling the i ndoor u nit ■ fixing the installation plate . . . . . . . . . . . ....

  • Page 28

    E- 28 deciding on where to install the air conditioner when deciding on the location of the air conditioner with the owner, the following restrictions must be taken into account. General do not install the air conditioner in a location where it will come into contact with the following elements: ◆ c...

  • Page 29

    E- 29 english respect the clearances and maximum lengths indicated in the diagram below when installing the unit. The designs of the unit and the connection valve are subject to change according to the model. 125mm (5inch) or more 600mm (24inch) minimum 350mm(14inch) minimum 100mm (4inch) minimum 60...

  • Page 30

    E- 30 air conditioner and accessories the following accessories are supplied with the air conditioner. ➢ the quantities are indicated in parentheses. Accessories in the indoor unit case accessories in the outdoor unit case ➢ the assembly cable is depending on the option. [if they are not supplied, u...

  • Page 31

    E- 31 english fixing the installation plate 30mm (1 ) 3 16 65mm 0 pipe hole (2 ) 9 16 (10) 252 (11) 275 (5 ) 140 1 2 (3) 90 5 8 (2 ) 60 3 8 (1 ) 30 3 16 410~730 16 ~ 1 8 28 3 4 () before fixing the installation plate to a wall or window frame, you must determine the position of the 65mm( inch) hole ...

  • Page 32

    E- 32 purging the unit on delivery, the indoor unit is loaded with an inert gas. All this gas must therefore be purged before connecting the assembly piping. To purge the inert gas, proceed as follows. Unscrew the caps at the end of each pipe. Result: all inert gas escapes from the indoor unit. ➢ to...

  • Page 33

    E- 33 english connecting the assembly cable (cont.) i nstalling the i ndoor u nit n1 l1 1 2 3 4 n1 1 2 3 l n e l n 1 e e n1 l1 1 2 3 4 2 1 l1 n1 e 2 1 l1 n1 e e e n1 l1 1 2 3 4 2 1 l1 n1 e 2 1 l1 n1 e 3 3 e e n l 1 indoor unit earth terminal earth terminal earth terminal outdoor unit indoor unit out...

  • Page 34

    E- 34 to install the drain hose, proceed as follows. 1 if necessary, connect the 2m(6ft. 7in) extension to the drain hose. 2 if you are using the extension, insulate the inside part of the extension drain hose with a shield. 3 pass the drain hose under the refrigerant piping, taking care to keep the...

  • Page 35

    E- 35 english installing and connecting the indoor unit assembly piping i nstalling the i ndoor u nit there are two refrigerant pipes of different diameters: ◆ a smaller one for the liquid refrigerant ◆ a larger one for the gas refrigerant a short length of piping is already fitted to the air condit...

  • Page 36

    E- 36 i nstalling the i ndoor u nit five metres(16ft 5in) of piping is supplied with the air conditioner(optional). This length can if necessary be: ◆ extended to a maximum of “l” m/ft. ◆ shortened as required ☛ if more than 5m(16ft 5in) of piping is required: ◆ the assembly cable must also be exten...

  • Page 37

    E- 37 english i nstalling the o utdoor u nit connecting the cables to the outdoor unit one electric cable must be connected to the outdoor unit: ◆ the assembly cable connecting the indoor unit to the outdoor unit 1 remove the terminal board cover on the side of the outdoor unit. 2 connect the assemb...

  • Page 38

    E- 38 i nstalling the o utdoor u nit auxiliary circuit breaker electrical work 1 the supply voltage must be the same as the rated voltage of the air conditioner. 2 prepare the power souce for exclusive use with the air conditioner. 3 use 15 amperes time delay fuse or circuit breaker. ➢ when using th...

  • Page 39

    E- 39 english i nstalling the o utdoor u nit checking correct earthing if the power distribution circuit does not have an earth or the earth does not comply with specifications, an earthing electrode must be installed. The corresponding accessories are not supplied with the air conditioner. 1 select...

  • Page 40

    E- 40 fixing the unit in position the outdoor unit must be installed on a rigid and stable base to avoid any increase in the noise level and vibration, particularly if the outdoor unit is to be installed close to a neighbour. If it is to be installed in a location exposed to strong winds or at a hei...

  • Page 41

    E- 41 english connecting up and purging the circuit c ompleting the i nstallation a b c d b (liquid) outdoor unit indoor unit gas pipe side liquid pipe side stem cap valve stem a (gas) vacuum pump the outdoor unit is loaded with sufficient r-22 refrigerant for 5m(16ft 5in) of piping. The air in the ...

  • Page 42

    E- 42 performing leak tests before completing the installation (insulation of the cables, hose and piping and fixing of the indoor unit to the installation plate), you must check that there are no gas leaks. To check for gas leaks on the... Then, using a leak detector, check the... Indoor unit flare...

  • Page 43

    E- 43 english once you have checked that there are no leaks in the system, you can insulate the piping, hose and cables and place the indoor unit on the installation plate. 1 to avoid condensation problems, place heat-resistant polyethylene foam separately around each refrigerant pipe in the lower p...

  • Page 44

    E- 44 checking and testing operations c ompleting the i nstallation to complete the installation, perform the following checks and tests to ensure that the air conditioner is operating correctly. 1 review all the following elements in the installation: ◆ installation site strength ◆ piping connectio...

  • Page 45

    E- 45 english explaining operations to the owner before leaving the premises on which you have installed the air conditioner, you should explain the following operations to the owner, making reference to the appropriate pages in the owner’s instruction booklet. 1 how to start and stop the air condit...

  • Page 46

    Electronics printed in korea this air conditioner is manufactured by: este aire acondicionado ha sido fabricado por: ce climatiseur est fabrique par:.