Samsung AVXWVH022EE Installation Manual

Other manuals for AVXWVH022EE: User Manual, User Manual, User Manual, User Manual
Manual is about: Wall Mounted Type Series

Summary of AVXWVH022EE

  • Page 1

    Avxwv@@_im_e_29819-1_4.14.09.Indd 1 2009-4-14 10:15:27.

  • Page 2: Contents

    E- 2 contents safety precautions ............................................................................................................ 3 accessories ............................................................................................................................ 6 selecting the ins...

  • Page 3

    E- 3 the following safety precautions must be taken when using your air conditioner. Warning • risk of electric shock can cause injury or death. • disconnect all remote electric power supplies before servicing, installing or cleaning. • installation must be done by the manufacturer or service agent ...

  • Page 4

    E- 4 p ower supply line or circuit breaker if the power cable of this air conditioner is damaged, it must be replaced by service agent or similarly qualified persons in order to avoid a hazard. The unit must be plugged into an independent circuit if applicable or connect the power cable to the auxili...

  • Page 5

    E- 5 make sure that you earth the cables. - do not connect the earth wire to the gas pipe, water pipe, lighting rod or telephone wire. If earthing is not complete, electric shock or fire may occur. Install the circuit breaker. - if the circuit breaker is not installed, electric shock or fire may occ...

  • Page 6

    E- 6 accessories the following accessories are supplied with the indoor unit. The type and quantity may differ depending on the specifications. Installation plate remote control batteries for remote control user’s manual installation manual avxwv@@_im_e_29819-1_4.14.09.Indd 6 2009-4-14 10:15:28.

  • Page 7

    E- 7 selecting the installation location indoor unit select a convenient location that permits the air to reach every corner of the area to be cooled. Pre-plan for easy and short routing of the refrigerant tubing and wiring to the outdoor unit. There should be no flammable gas, alkaline, substances ...

  • Page 8

    E- 8 fixing the installation plate before fixing the installation plate to the wall or window frame, you must determine the position of the 65mm hole through which the cable, pipe and hose pass to connect the indoor unit to the outdoor unit. When facing the wall, the pipe and cable can be connected ...

  • Page 9

    E- 9 eev kit installation preparing for installation 1 check dimension and installation location. 2 check installation place. By using a pattern sheet, check required installation space. Concrete suspension bolt(3/8" or m10)-field supply hole in anchor hole in plug insert ...

  • Page 10

    E- 10 connection of refrigerant piping & insulation 1 insert bot anchors, use existing ceiling supports or construct a suitable support. Caution ensure the ceiling is strong enough to support the weight of the indoor unit. Before hanging the unit, test the strength of each attached suspension bolt. ...

  • Page 11

    E- 11 eev kit installation (continued) a b c wiring & assigning address room a room b outdoor unit another eev kit 1 connect the ac power cable and communication cable from the outdoor unit to terminal, then connect the cable to another eev kit. 2 connect the ac power cable and communication cable t...

  • Page 12

    E- 12 if you press a key on the pcb, the display will show you a step of appropriate eev kit. Eev kit installation (continued) function of display key function key no. Meaning example k1 step of eev kit a 19 (19 x 10 = 190 step) k2 step of eev kit b k3 step of eev kit c k4 - - the numbers which are ...

  • Page 13

    E- 13 refrigerant oil torque wrench flare nut union spanner b a c connecting the refrigerant pipe there are 2 refrigerant pipes of different diameters: the smaller one is for the liquid refrigerant the larger one is for the gas refrigerant a short pipe is already fitted to the air conditioner. You m...

  • Page 14

    E- 14 cutting/flaring the pipes 1 make sure that you prepared the required tools. (pipe cutter, reamer, flaring tool and pipe holder) 2 if you want to shorten the pipe, cut it using a pipe cutter ensuring that the cut edge remains at 90° with the side of the pipe. There are some examples of correctl...

  • Page 15

    E- 15 performing leak test & insulation insulation c d after checking for gas leaks in the system, insulate the pipe, hose and cables. Then place the indoor unit on the installation plate. 1 to avoid condensation problems, place heat-resistant polyethylene foam separately around each refrigerant pip...

  • Page 16

    E- 16 performing leak test & insulation (continued) 8 select the insulator of the refrigerant pipe. Insulate the gas side and liquid side pipe referring to the thickness according to the pipe size. The thickness according to the pipe size is a standard of the indoor temperature of 27°c and humidity ...

  • Page 17

    E- 17 installing and connecting the drain hose of the indoor unit when installing the drain hose for the indoor unit, check if condensation draining is adequate. When passing the drain hose through the 65-mm hole drilled in the wall, check the following: drain hose installation: 1 if necessary, conn...

  • Page 18

    E- 18 wiring work silver solder n l n l n l n l indoor unit 1 outdoor unit indoor unit 2 indoor unit 3 wired remote control 220-240v~ elb : essential installation eev kit indoor unit 4 indoor unit 5 indoor unit 6 ceiling, wall-mounted indoor unit. Selecting compressed ring terminal 1 before wiring w...

  • Page 19

    E- 19 wiring work unit model rating current avxwv 022 028 036 056 071 0.13a 0.18a 0.19a 0.30a 0.30a rating current specification of electronic wire power supply mccb elb power cable earth cable communication cable max : 242v min : 198v x a x a, 30mma 0.1 sec 2.5mm 2 2.5mm 2 0.75~1.5mm ...

  • Page 20

    E- 20 wiring work (continued) select the power cable in accordance with relevant local and national regulations. Wire size must comply with local and national code. For the power cable, use the grade of h07rn-f or h05rn-f materials. You should connect the power cable into the power cable terminal an...

  • Page 21

    E- 21 indoor unit setting 1 before installing the indoor unit, assign an address to the indoor unit according to the air conditioning system plan. 2 the address of the indoor unit is assigned by adjusting main(sw01, sw02) and rmc(sw03, sw04) rotary switches. The designs and shape are subject to chan...

  • Page 22

    E- 22 additional functions no. Function on off sw05 k1 - - - k2 centralized controller not use use k3 - - - k4 - - - no. Function on off sw06 k5 heating current temperature compensation + 2°c + 5°c k6 filter time 1,000 hours 2,000 hours k7 - - - ...

  • Page 23

    E- 23 final checks and user tips to complete the installation, perform the following checks and tests to ensure that the air conditioner operates correctly. 1 check the following: strength of the installation site tightness of pipe connection to detect gas leak electric wiring connection heat-resist...

  • Page 24

    E- 24 troubleshooting detection of errors if an error occurs during the operation, one or more led flickers and the operation is stopped except the led. If you re-operate the air conditioner, it operates normally at first, then detect an error again. Led display led display on the indoor unit on fli...

  • Page 25

    E- 25 troubleshooting on flickering x off if you turn off the air conditioner when the led is flickering, the led is also turned off. If you re-operate the air conditioner, it operates normally at first, then detects an error again. Abnormal conditions indicators remarks self-diagnostic error (inclu...

  • Page 26

    "eee yönetmeliğine uygundur" "this eee is compliant with rohs" avxc1@@_im_e_29824-1_5.05.09.Indd 30 2009-5-12 8:46:05.

  • Page 27: Installation

    E installation manual wall-mounted type series vivace type : avxwv db98-29819a(1) air conditioner avxwv@@_im_e_29819-1_5.08.09.Indd 27 2009-5-8 16:58:36.