Sentinel HDX Quick Start Manual And Installation Manual - page 12
Test Recording and Assessment
The Sentinel HDx unit should now be physically mounted in the proper location on the vehicle’s
windshield and powered by a 12 volt continuous fused power circuit. It is now time to run a test
recording to confirm proper camera angles and vertical level adjustment.
2. Locate and depress the yellow colored Panic Button on the bottom portion of the
camera unit. You will witness the camera status LED illuminate solid Purple,
indicating that an event is being recorded
3. Utilizing the AEGIS software installation, review the video for proper operation and
levelness. If you have enabled the optional audio recording feature, verify proper audio
reproduction of the test.
12
Phone 512-651-5277
1. Hold the panic button for 6 seconds, then release. The unit will check if it is properly mounted.
If incorrect, then status LED will show magenta. Either unit can be adjusted for better
placement, or you can calibrate unit to this mounting setting if that is the preferred position of
the camera for the installation. To calibrate to this position, press and hold the panic button
again for an additional 6 seconds and the unit will auto calibrate and provide a green status
LED indicating it has been properly configured.
Calibrate the unit as follows: